Substrate dependent stability of conducting polymer coatings on medical electrodes

被引:175
作者
Green, Rylie A. [1 ]
Hassarati, Rachelle T. [1 ]
Bouchinet, Lucie [1 ]
Lee, Chaekyung S. [1 ]
Cheong, Gin L. M. [1 ]
Yu, Jin F. [1 ]
Dodds, Christopher W. [1 ]
Suaning, Gregg J. [1 ]
Poole-Warren, Laura A. [1 ]
Lovell, Nigel H. [1 ]
机构
[1] Univ New S Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
基金
澳大利亚研究理事会;
关键词
Electroactive polymer; Electrode; Laser manufacturing; Electrical stimulation; Implant stability; ELECTRICAL-STIMULATION; NEURAL INTERFACES; POLY(3,4-ETHYLENEDIOXYTHIOPHENE); POLYPYRROLE; IMPEDANCE; ADHESION; BIOMATERIALS; PERFORMANCE; GROWTH;
D O I
10.1016/j.biomaterials.2012.05.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conducting polymer (CP) coatings on medical electrodes have the potential to provide superior performance when compared to conventional metallic electrodes, but their stability is strongly dependant on the substrate properties. The aim of this study was to examine the effect of laser roughening of underlying platinum (Pt) electrode surfaces on the mechanical, electrical and biological performance of CP coatings. In addition, the impact of dopant type on electrical performance and stability was assessed. The CP poly(ethylene dioxythiophene) (PEDOT) was coated on Pt microelectrode arrays, with three conventional dopant ions. The in vitro electrical characteristics were assessed by cyclic voltammetry and biphasic stimulation. Results showed that laser roughening of the underlying substrate did not affect the charge injection limit of the coated material, but significantly improved the passive stability and chronic stimulation lifetime without failure of the coating. Accelerated material ageing and long-term biphasic stimulus studies determined that some PEDOT variants experienced delamination within as little as 10 days when the underlying Pt was smooth, but laser roughening to produce a surface index of 2.5 improved stability, such that more than 1.3 billion stimulation cycles could be applied without evidence of failure. PEDOT doped with paratoluene sulfonate (PEDOT/pTS) was found to be the most stable CP on roughened Pt, and presented a surface topography which encouraged neural cell attachment. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:5875 / 5886
页数:12
相关论文
共 44 条
[21]   Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant [J].
Green, Rylie A. ;
Lovell, Nigel H. ;
Wallace, Gordon G. ;
Poole-Warren, Laura A. .
BIOMATERIALS, 2008, 29 (24-25) :3393-3399
[22]  
Green RA, 2012, SENSOR MATER, V24, P165
[23]   Impact of co-incorporating laminin peptide dopants and neurotrophic growth factors on conducting polymer properties [J].
Green, Rylie A. ;
Lovell, Nigel H. ;
Poole-Warren, Laura A. .
ACTA BIOMATERIALIA, 2010, 6 (01) :63-71
[24]   Cell attachment functionality of bioactive conducting polymers for neural interfaces [J].
Green, Rylie A. ;
Lovell, Nigel H. ;
Poole-Warren, Laura A. .
BIOMATERIALS, 2009, 30 (22) :3637-3644
[25]  
Guiseppi-Elie A., 1983, Journal de Physique Colloque, V44, P193, DOI 10.1051/jphyscol:1983339
[26]  
HORBETT TA, 1993, CARDIOVASC PATHOL, V2, pS137
[27]   Accelerated aging for testing polymeric biomaterials and medical devices [J].
Hukins, D. W. L. ;
Mahomed, A. ;
Kukureka, S. N. .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (10) :1270-1274
[28]   An interpretation of the failure paths of roughened metal/polymer interfaces [J].
Lee, HY ;
Qu, JM .
METALS AND MATERIALS-KOREA, 2001, 7 (02) :101-105
[29]   Highly stable carbon nanotube doped poly(3,4-ethylenedioxythiophene) for chronic neural stimulation [J].
Luo, Xiliang ;
Weaver, Cassandra L. ;
Zhou, David D. ;
Greenberg, Robert ;
Cui, Xinyan T. .
BIOMATERIALS, 2011, 32 (24) :5551-5557
[30]   Ethylene oxide sterilization of medical devices: A review [J].
Mendes, Gisela C. C. ;
Brandao, Teresa R. S. ;
Silva, Cristina L. M. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2007, 35 (09) :574-581