Substrate dependent stability of conducting polymer coatings on medical electrodes

被引:175
作者
Green, Rylie A. [1 ]
Hassarati, Rachelle T. [1 ]
Bouchinet, Lucie [1 ]
Lee, Chaekyung S. [1 ]
Cheong, Gin L. M. [1 ]
Yu, Jin F. [1 ]
Dodds, Christopher W. [1 ]
Suaning, Gregg J. [1 ]
Poole-Warren, Laura A. [1 ]
Lovell, Nigel H. [1 ]
机构
[1] Univ New S Wales, Grad Sch Biomed Engn, Sydney, NSW 2052, Australia
基金
澳大利亚研究理事会;
关键词
Electroactive polymer; Electrode; Laser manufacturing; Electrical stimulation; Implant stability; ELECTRICAL-STIMULATION; NEURAL INTERFACES; POLY(3,4-ETHYLENEDIOXYTHIOPHENE); POLYPYRROLE; IMPEDANCE; ADHESION; BIOMATERIALS; PERFORMANCE; GROWTH;
D O I
10.1016/j.biomaterials.2012.05.017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conducting polymer (CP) coatings on medical electrodes have the potential to provide superior performance when compared to conventional metallic electrodes, but their stability is strongly dependant on the substrate properties. The aim of this study was to examine the effect of laser roughening of underlying platinum (Pt) electrode surfaces on the mechanical, electrical and biological performance of CP coatings. In addition, the impact of dopant type on electrical performance and stability was assessed. The CP poly(ethylene dioxythiophene) (PEDOT) was coated on Pt microelectrode arrays, with three conventional dopant ions. The in vitro electrical characteristics were assessed by cyclic voltammetry and biphasic stimulation. Results showed that laser roughening of the underlying substrate did not affect the charge injection limit of the coated material, but significantly improved the passive stability and chronic stimulation lifetime without failure of the coating. Accelerated material ageing and long-term biphasic stimulus studies determined that some PEDOT variants experienced delamination within as little as 10 days when the underlying Pt was smooth, but laser roughening to produce a surface index of 2.5 improved stability, such that more than 1.3 billion stimulation cycles could be applied without evidence of failure. PEDOT doped with paratoluene sulfonate (PEDOT/pTS) was found to be the most stable CP on roughened Pt, and presented a surface topography which encouraged neural cell attachment. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:5875 / 5886
页数:12
相关论文
共 44 条
[1]  
[Anonymous], 2011, F1980072011 ASTM
[2]  
[Anonymous], FRONT NEUROENG
[3]  
Baek S, 2009, P AUSTR SOC BIOM TIS
[4]   On the Stability of Poly-Ethylenedioxythiopene as Coating Material for Active Neural Implants [J].
Boretius, Tim ;
Schuettler, Martin ;
Stieglitz, Thomas .
ARTIFICIAL ORGANS, 2011, 35 (03) :245-248
[5]   Estimation of the strength of adhesion between a thermoresponsive polymer coating and nitinol wire [J].
Burke, Martin ;
Clarke, Brenda ;
Rochev, Yuri ;
Gorelov, Alexandar ;
Carroll, William .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (05) :1971-1979
[6]   Effects of phase duration and electrode separation on loudness growth in cochlear implant listeners [J].
Chatterjee, N ;
Fu, QJ ;
Shannon, RV .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 107 (03) :1637-1644
[7]   Neural stimulation and recording electrodes [J].
Cogan, Stuart F. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2008, 10 :275-309
[8]  
Collier JH, 2000, J BIOMED MATER RES, V50, P574, DOI 10.1002/(SICI)1097-4636(20000615)50:4<574::AID-JBM13>3.0.CO
[9]  
2-I
[10]   Preparation, characterization and anion exchange properties of polypyrrole/carbon nanotube nanocomposites [J].
Cui, XL ;
Engelhard, MH ;
Lin, YH .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2006, 6 (02) :547-553