Stereoscopic full aperture imaging in nuclear medicine

被引:0
|
作者
Strocovsky, Sergio G. [1 ]
Otero, Dino [2 ]
机构
[1] Comis Nacl Energia Atom, Ctr Atom Ezeiza, Ezeiza, Buenos Aires, Argentina
[2] Univ Tecnol Nacl, Fac Reg Buenos Aires, Escuela Postgrad, Buenos Aires, DF, Argentina
来源
AIP ADVANCES | 2011年 / 1卷 / 02期
关键词
EMISSION COMPUTERIZED-TOMOGRAPHY; CODED-APERTURE; RECONSTRUCTION; CAMERA; COLLIMATOR; DESIGN; IMAGES; SYSTEM; SPECT;
D O I
10.1063/1.3596378
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Images of planar scintigraphy and single photon emission computerized tomography (SPECT) used in nuclear medicine are often low quality. They usually appear to be blurred and noisy. This problem is due to the low spatial resolution and poor sensitivity of the acquisition technique with the gamma camera (GC). Other techniques, such as coded aperture imaging (CAI) reach higher spatial resolutions than GC. However, CAI is not frequently used for imaging in nuclear medicine, due to the decoding complexity of some images and the difficulty in controlling the noise magnitude. Summing up, the images obtained through GC are low quality and it is still difficult to implement CAI technique. A novel technique, full aperture Imaging (FAI), also uses gamma ray-encoding to obtain images, but the coding system and the method of images reconstruction are simpler than those used in CAI. In addition, FAI also reaches higher spatial resolution than GC. In this work, the principles of FAI technique and the method of images reconstruction are explained in detail. The FAI technique is tested by means of Monte Carlo simulations with filiform and spherical sources. Spatial resolution tests of GC versus FAI were performed using two different source-detector distances. First, simulations were made without interposing any material between the sources and the detector. Then, other more realistic simulations were made. In these, the sources were placed in the centre of a rectangular prismatic region, filled with water. A rigorous comparison was made between GC and FAI images of the linear filiform sources, by means of two methods: mean fluence profile graphs and correlation tests. Finally, three-dimensional capacity of FAI was tested with two spherical sources. The results show that FAI technique has greater sensitivity (> 100 times) and greater spatial resolution (> 2.6 times) than that of GC with LEHR collimator, in both cases, with and without attenuating material and long and short-distance configurations. The FAI decoding algorithm reconstructs simultaneously four different projections which are located in separate image fields on the detector plane, while GC produces only one projection per acquisition. Simulations have allowed comparison of both techniques under ideal identical conditions. Our results show it is possible to apply an extremely simple encoded imaging technique, and get three-dimensional radioactivity information for simplistic geometry sources. The results are promising enough to evaluate the possibility of future research with more complex sources typical of nuclear medicine imaging. Copyright 2011 Author(s). This article is distributed under a Creative Commons Attribution 3.0 Unported License. [doi:10.1063/1.3596378]
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Radiological and nuclear medicine imaging of gastroenteropancreatic neuroendocrine tumours
    Sundin, Anders
    BEST PRACTICE & RESEARCH CLINICAL GASTROENTEROLOGY, 2012, 26 (06) : 803 - 818
  • [32] Deep learning in nuclear medicine: from imaging to therapy
    Zhang, Meng-Xin
    Liu, Peng-Fei
    Zhang, Meng-Di
    Su, Pei-Gen
    Shang, He-Shan
    Zhu, Jiang-Tao
    Wang, Da-Yong
    Ji, Xin-Ying
    Liao, Qi-Ming
    ANNALS OF NUCLEAR MEDICINE, 2025, : 424 - 440
  • [33] Intelligent Imaging: Artificial Intelligence Augmented Nuclear Medicine
    Currie, Geoffrey M.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2019, 47 (03) : 217 - 222
  • [34] Nuclear medicine multimodal imaging of endocrine digestive tumors
    Calzada, M.
    Keller, I.
    Potier, L.
    Gaura-Schmidt, V.
    Maurel, G.
    Kiffel, T.
    Dumont, A.
    Christin-Maitre, S.
    Devaux, J. -Y
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2010, 34 (08): : 444 - 450
  • [35] The Established Nuclear Medicine Modalities for Imaging of Bone Metastases
    Jabeen, Nazish
    Rasheed, Rashid
    Rafique, Asma
    Murtaza, Ghulam
    CURRENT MEDICAL IMAGING, 2019, 15 (09) : 819 - 830
  • [36] Visual demonstration of aliasing in planar nuclear medicine imaging: The importance of correct collimator selection by nuclear medicine practitioners
    Elliott, J.
    O'Sullivan, P.
    Crooker, T.
    Barnden, T.
    RADIOGRAPHY, 2019, 25 (04) : E119 - E122
  • [37] Periodic wrappings in coded aperture imaging
    Shutler, Paul M. E.
    Springham, Stuart V.
    Talebitaher, Alireza
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 738 : 132 - 148
  • [38] A coded aperture microscope for X-ray fluorescence full-field imaging
    Siddons, D. P.
    Kuczewski, A. J.
    Rumaiz, A. K.
    Tappero, R.
    Idir, M.
    Nakhoda, K.
    Khanfri, J.
    Singh, V
    Farquhar, E. R.
    Sullivan, M.
    Abel, D.
    Brady, D. J.
    Yuan, X.
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 1703 - 1706
  • [39] Multi-molecule imaging and inter-molecular imaging in nuclear medicine
    Shimazoe, Kenji
    Uenomachi, Mizuki
    BIO-ALGORITHMS AND MED-SYSTEMS, 2022, 18 (01) : 127 - 134
  • [40] Time-Multiplexed Coded Aperture Imaging: Learned Coded Aperture and Pixel Exposures for Compressive Imaging Systems
    Vargas, Edwin
    Martel, Julien N. P.
    Wetzstein, Gordon
    Arguello, Henry
    2021 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV 2021), 2021, : 2672 - 2682