Stereoscopic full aperture imaging in nuclear medicine

被引:0
|
作者
Strocovsky, Sergio G. [1 ]
Otero, Dino [2 ]
机构
[1] Comis Nacl Energia Atom, Ctr Atom Ezeiza, Ezeiza, Buenos Aires, Argentina
[2] Univ Tecnol Nacl, Fac Reg Buenos Aires, Escuela Postgrad, Buenos Aires, DF, Argentina
来源
AIP ADVANCES | 2011年 / 1卷 / 02期
关键词
EMISSION COMPUTERIZED-TOMOGRAPHY; CODED-APERTURE; RECONSTRUCTION; CAMERA; COLLIMATOR; DESIGN; IMAGES; SYSTEM; SPECT;
D O I
10.1063/1.3596378
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Images of planar scintigraphy and single photon emission computerized tomography (SPECT) used in nuclear medicine are often low quality. They usually appear to be blurred and noisy. This problem is due to the low spatial resolution and poor sensitivity of the acquisition technique with the gamma camera (GC). Other techniques, such as coded aperture imaging (CAI) reach higher spatial resolutions than GC. However, CAI is not frequently used for imaging in nuclear medicine, due to the decoding complexity of some images and the difficulty in controlling the noise magnitude. Summing up, the images obtained through GC are low quality and it is still difficult to implement CAI technique. A novel technique, full aperture Imaging (FAI), also uses gamma ray-encoding to obtain images, but the coding system and the method of images reconstruction are simpler than those used in CAI. In addition, FAI also reaches higher spatial resolution than GC. In this work, the principles of FAI technique and the method of images reconstruction are explained in detail. The FAI technique is tested by means of Monte Carlo simulations with filiform and spherical sources. Spatial resolution tests of GC versus FAI were performed using two different source-detector distances. First, simulations were made without interposing any material between the sources and the detector. Then, other more realistic simulations were made. In these, the sources were placed in the centre of a rectangular prismatic region, filled with water. A rigorous comparison was made between GC and FAI images of the linear filiform sources, by means of two methods: mean fluence profile graphs and correlation tests. Finally, three-dimensional capacity of FAI was tested with two spherical sources. The results show that FAI technique has greater sensitivity (> 100 times) and greater spatial resolution (> 2.6 times) than that of GC with LEHR collimator, in both cases, with and without attenuating material and long and short-distance configurations. The FAI decoding algorithm reconstructs simultaneously four different projections which are located in separate image fields on the detector plane, while GC produces only one projection per acquisition. Simulations have allowed comparison of both techniques under ideal identical conditions. Our results show it is possible to apply an extremely simple encoded imaging technique, and get three-dimensional radioactivity information for simplistic geometry sources. The results are promising enough to evaluate the possibility of future research with more complex sources typical of nuclear medicine imaging. Copyright 2011 Author(s). This article is distributed under a Creative Commons Attribution 3.0 Unported License. [doi:10.1063/1.3596378]
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Semiconductor detectors for Compton imaging in nuclear medicine
    Harkness, L. J.
    Judson, D. S.
    Kennedy, H.
    Sweeney, A.
    Boston, A. J.
    Boston, H. C.
    Cresswell, J. R.
    Nolan, P. J.
    Sampson, J. A.
    Burrows, I.
    Groves, J.
    Headspith, J.
    Lazarus, I. H.
    Simpson, J.
    Bimson, W. E.
    Kemp, G. J.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [22] Radiation dose in nuclear medicine: the hybrid imaging
    Salvatori, Massimo
    Rizzo, Alessio
    Rovera, Guido
    Indovina, Luca
    Schillaci, Orazio
    RADIOLOGIA MEDICA, 2019, 124 (08): : 768 - 776
  • [23] Glioblastoma Multiforme Imaging: The Role of Nuclear Medicine
    Alexiou, George A.
    Tsiouris, Spyridon
    Voulgaris, Spyridon
    Kyritsis, Athanasios P.
    Fotopoulos, Andreas D.
    CURRENT RADIOPHARMACEUTICALS, 2012, 5 (04) : 308 - 313
  • [24] Observations on the role of nuclear medicine in molecular imaging
    Hnatowich, DJ
    JOURNAL OF CELLULAR BIOCHEMISTRY, 2002, : 18 - 24
  • [25] A Novel Scheme of Compton Imaging for Nuclear Medicine
    Pausch, Guntram
    Golnik, Christian
    Schulz, Alexander
    Enghardt, Wolfgang
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [26] Molecular imaging in nuclear medicine, from biomarkers to theranostics
    Guedj, Eric
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2018, 202 (07): : 1501 - 1508
  • [27] Advanced Nuclear Medicine and Molecular Imaging in the Diagnosis of Cardiomyopathy
    Yang, Ming
    Arsanjani, Reza
    Roarke, Michael C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (05) : 1208 - 1217
  • [28] Current Applications for Nuclear Medicine Imaging in Pulmonary Disease
    Kusmirek, Joanna E.
    Magnusson, Josiah D.
    Perlman, Scott B.
    CURRENT PULMONOLOGY REPORTS, 2020, 9 (03) : 82 - 95
  • [29] Nuclear medicine imaging to predict response to radiotherapy: A review
    Van de Wiele, C
    Lahorte, C
    Oyen, W
    Boerman, O
    Goethals, I
    Slegers, G
    Dierckx, RA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (01): : 5 - 15
  • [30] Photons across medicine: relating optical and nuclear imaging
    Nordstrom, Robert
    Cherry, Simon
    Azhdarinia, Ali
    Sevick-Muraca, Eva
    VanBrocklin, Henry
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (12): : 2751 - 2762