Stereoscopic full aperture imaging in nuclear medicine

被引:0
|
作者
Strocovsky, Sergio G. [1 ]
Otero, Dino [2 ]
机构
[1] Comis Nacl Energia Atom, Ctr Atom Ezeiza, Ezeiza, Buenos Aires, Argentina
[2] Univ Tecnol Nacl, Fac Reg Buenos Aires, Escuela Postgrad, Buenos Aires, DF, Argentina
来源
AIP ADVANCES | 2011年 / 1卷 / 02期
关键词
EMISSION COMPUTERIZED-TOMOGRAPHY; CODED-APERTURE; RECONSTRUCTION; CAMERA; COLLIMATOR; DESIGN; IMAGES; SYSTEM; SPECT;
D O I
10.1063/1.3596378
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Images of planar scintigraphy and single photon emission computerized tomography (SPECT) used in nuclear medicine are often low quality. They usually appear to be blurred and noisy. This problem is due to the low spatial resolution and poor sensitivity of the acquisition technique with the gamma camera (GC). Other techniques, such as coded aperture imaging (CAI) reach higher spatial resolutions than GC. However, CAI is not frequently used for imaging in nuclear medicine, due to the decoding complexity of some images and the difficulty in controlling the noise magnitude. Summing up, the images obtained through GC are low quality and it is still difficult to implement CAI technique. A novel technique, full aperture Imaging (FAI), also uses gamma ray-encoding to obtain images, but the coding system and the method of images reconstruction are simpler than those used in CAI. In addition, FAI also reaches higher spatial resolution than GC. In this work, the principles of FAI technique and the method of images reconstruction are explained in detail. The FAI technique is tested by means of Monte Carlo simulations with filiform and spherical sources. Spatial resolution tests of GC versus FAI were performed using two different source-detector distances. First, simulations were made without interposing any material between the sources and the detector. Then, other more realistic simulations were made. In these, the sources were placed in the centre of a rectangular prismatic region, filled with water. A rigorous comparison was made between GC and FAI images of the linear filiform sources, by means of two methods: mean fluence profile graphs and correlation tests. Finally, three-dimensional capacity of FAI was tested with two spherical sources. The results show that FAI technique has greater sensitivity (> 100 times) and greater spatial resolution (> 2.6 times) than that of GC with LEHR collimator, in both cases, with and without attenuating material and long and short-distance configurations. The FAI decoding algorithm reconstructs simultaneously four different projections which are located in separate image fields on the detector plane, while GC produces only one projection per acquisition. Simulations have allowed comparison of both techniques under ideal identical conditions. Our results show it is possible to apply an extremely simple encoded imaging technique, and get three-dimensional radioactivity information for simplistic geometry sources. The results are promising enough to evaluate the possibility of future research with more complex sources typical of nuclear medicine imaging. Copyright 2011 Author(s). This article is distributed under a Creative Commons Attribution 3.0 Unported License. [doi:10.1063/1.3596378]
引用
收藏
页数:18
相关论文
共 50 条
  • [1] New principles in Nuclear Medicine Imaging: A Full Aperture Stereoscopic Imaging Technique
    Strocovsky, Sergio G.
    Otero, Dino
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3630 - 3633
  • [2] FOURIER CODED-APERTURE IMAGING IN NUCLEAR-MEDICINE
    CHOU, C
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1994, 141 (03) : 179 - 184
  • [3] Coded aperture full-stokes imaging spectropolarimeter
    Chen, Zeyu
    Zhang, Chunmin
    Mu, Tingkui
    Wang, Yanqiang
    He, Yifan
    Yan, Tingyu
    Chen, Zhengyi
    OPTICS AND LASER TECHNOLOGY, 2022, 150
  • [4] Three-dimensional coded aperture techniques in diagnostic nuclear medicine imaging
    Zhang, L
    Lanza, RC
    Hom, BKP
    Zimmerman, RE
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 364 - 373
  • [5] Artificial Intelligence in Nuclear Medicine Physics and Imaging
    Papachristou, Konstantinos
    Panagiotidis, Emmanouil
    Makridou, Anna
    Kalathas, Theodoros
    Masganis, Vasilis
    Paschali, Anna
    Aliberti, Maria
    Chatzipavlidou, Vasiliki
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2023, 26 (01) : 57 - 65
  • [6] High-resolution imaging using a translating coded aperture
    Mahalanobis, Abhijit
    Shilling, Richard
    Muise, Robert
    Neifeld, Mark
    OPTICAL ENGINEERING, 2017, 56 (08)
  • [7] Neoangiogenesis imaging in nuclear medicine
    Deshayes, E.
    Dunet, V.
    Rueegg, C.
    Prior, J. O.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2012, 36 (10): : 619 - 626
  • [8] Imaging in Diagnostic Nuclear Medicine
    Denisova, N. V.
    TECHNICAL PHYSICS, 2018, 63 (09) : 1375 - 1383
  • [9] NUCLEAR MEDICINE IMAGING IN DEMENTIA
    Kondakov, A. K.
    Znamensky, I. A.
    Mosin, D. Yu
    Grechko, A., V
    BULLETIN OF RUSSIAN STATE MEDICAL UNIVERSITY, 2016, (04): : 40 - 43
  • [10] Nuclear Medicine Imaging in Epilepsy
    Sriwastwa, Aakanksha
    Trout, Andrew Timothy
    Mahoney, Bruce Wayne
    Wang, Lily L.
    Scheler, Jennifer L.
    RADIOGRAPHICS, 2025, 45 (01)