Liquid chromatography/electrospray ionization tandem mass spectrometric screening and confirmation methods for β2-agonists in human or equine urine

被引:76
作者
Thevis, M [1 ]
Opfermann, G [1 ]
Schänzer, W [1 ]
机构
[1] German Sport Univ, Inst Biochem, D-50933 Cologne, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2003年 / 38卷 / 11期
关键词
doping; mass spectrometry; sports; stimulants; anabolic agents; horse; urine;
D O I
10.1002/jms.542
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray ionization (ESI) mass spectra of 19 common beta(2)-agonists were investigated in terms of fragmentation pattern and dissociation behavior of the analytes, proving the origin of fragment ions and indicating mechanisms of charge-driven and charge-remote fragmentation. Based on these data, liquid chromatographic/ESI tandem mass spectrometric (LC/ESI-MS/MS) screening and confirmation methods were developed for doping control purposes. These procedures employ established sample preparation steps including either acidic or enzymatic hydrolysis, alkaline extraction and, in the case of equine urine specimens, acidic re-extraction of the analytes. In addition, a degradation product of formoterol caused by acidic hydrolysis during sample preparation could be identified and utilized as target compound in screening and also confirmation methods. The screening procedures cover 18 or 19beta(2)-agonists, the estimated limits of detection of which for equine and human urine samples vary between 2 and 100 ng ml(-1) and between 2 and 50 ng ml(-1), respectively. A single LC/MS/MS analysis can be performed in 9 min. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:1197 / 1206
页数:10
相关论文
共 29 条
  • [1] Determination of clenbuterol in human urine by GC-MS-MS-MS:: confirmation analysis in antidoping control
    Amendola, L
    Colamonici, C
    Rossi, F
    Botrè, F
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01): : 7 - 16
  • [2] Identification of ractopamine residues in tissue and urine samples at ultra-trace level using liquid chromatography - positive electrospray tandem mass spectrometry
    Antignac, JP
    Marchand, P
    Le Bizec, B
    Andre, F
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (01): : 59 - 66
  • [3] Biancotto G, 1997, J MASS SPECTROM, V32, P781, DOI 10.1002/(SICI)1096-9888(199707)32:7<781::AID-JMS532>3.0.CO
  • [4] 2-5
  • [5] Biancotto G, 1999, J MASS SPECTROM, V34, P1346, DOI 10.1002/(SICI)1096-9888(199912)34:12<1346::AID-JMS893>3.0.CO
  • [6] 2-#
  • [7] Bocca B, 2003, J AOAC INT, V86, P8
  • [8] Quantitative multi-residue determination of beta-agonists in bovine urine using on-line immunoaffinity extraction coupled column packed capillary liquid chromatography tandem mass spectrometry
    Cai, J
    Henion, J
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (02): : 357 - 370
  • [9] Damasceno L, 2000, J MASS SPECTROM, V35, P1285, DOI 10.1002/1096-9888(200011)35:11<1285::AID-JMS61>3.0.CO
  • [10] 2-L