An artificial intelligence-accelerated 2-minute multi-shot echo planar imaging protocol for comprehensive high-quality clinical brain imaging

被引:15
作者
Clifford, Bryan [1 ]
Conklin, John [2 ]
Huang, Susie Y. [2 ]
Feiweier, Thorsten [3 ]
Hosseini, Zahra [4 ]
Goncalves Filho, Augusto Lio M. [2 ]
Tabari, Azadeh [2 ]
Demir, Serdest [2 ]
Lo, Wei-Ching [1 ]
Longo, Maria Gabriela Figueiro [2 ]
Lev, Michael [2 ]
Schaefer, Pam [2 ]
Rapalino, Otto [2 ]
Setsompop, Kawin [5 ,6 ]
Bilgic, Berkin [7 ]
Cauley, Stephen [7 ]
机构
[1] Siemens Med Solut USA, 149 13th St,Suite 2301, Boston, MA 02129 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA USA
[3] Siemens Healthcare GmbH, Erlangen, Germany
[4] Siemens Med Solut USA, Atlanta, GA USA
[5] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[6] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[7] Harvard Med Sch, AA Martinos Ctr Biomed Imaging, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
brain; clinical applications; machine learning; artificial intelligence; MOTION CORRECTION; MRI; SENSE; RECONSTRUCTION; CORRECT; TRENDS; IMAGES;
D O I
10.1002/mrm.29117
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose We introduce and validate an artificial intelligence (AI)-accelerated multi-shot echo-planar imaging (msEPI)-based method that provides T1w, T2w, T2*, T2-FLAIR, and DWI images with high SNR, high tissue contrast, low specific absorption rates (SAR), and minimal distortion in 2 minutes. Methods The rapid imaging technique combines a novel machine learning (ML) scheme to limit g-factor noise amplification and improve SNR, a magnetization transfer preparation module to provide clinically desirable contrast, and high per-shot EPI undersampling factors to reduce distortion. The ML training and image reconstruction incorporates a tunable parameter for controlling the level of denoising/smoothness. The performance of the reconstruction method is evaluated across various acceleration factors, contrasts, and SNR conditions. The 2-minute protocol is directly compared to a 10-minute clinical reference protocol through deployment in a clinical setting, where five representative cases with pathology are examined. Results Optimization of custom msEPI sequences and protocols was performed to balance acquisition efficiency and image quality compared to the five-fold longer clinical reference. Training data from 16 healthy subjects across multiple contrasts and orientations were used to produce ML networks at various acceleration levels. The flexibility of the ML reconstruction was demonstrated across SNR levels, and an optimized regularization was determined through radiological review. Network generalization toward novel pathology, unobserved during training, was illustrated in five clinical case studies with clinical reference images provided for comparison. Conclusion The rapid 2-minute msEPI-based protocol with tunable ML reconstruction allows for advantageous trade-offs between acquisition speed, SNR, and tissue contrast when compared to the five-fold slower standard clinical reference exam.
引用
收藏
页码:2453 / 2463
页数:11
相关论文
共 49 条
[1]   Inpatient CT and MRI Utilization: Trends in the Academic Hospital Setting [J].
Agarwal, Rajan ;
Bergey, Meredith ;
Sonnad, Seema ;
Butowsky, Howard ;
Bhargavan, Mythreyi ;
Bleshman, Michael H. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2010, 7 (12) :949-955
[2]   MoDL: Model-Based Deep Learning Architecture for Inverse Problems [J].
Aggarwal, Hemant K. ;
Mani, Merry P. ;
Jacob, Mathews .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (02) :394-405
[3]   How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[4]   Toward Quantifying the Prevalence, Severity, and Cost Associated With Patient Motion During Clinical MR Examinations [J].
Andre, Jalal B. ;
Bresnahan, Brian W. ;
Mossa-Basha, Mahmud ;
Hoff, Michael N. ;
Smith, C. Patrick ;
Anzai, Yoshimi ;
Cohen, Wendy A. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (07) :689-695
[5]   Augmented generalized SENSE reconstruction to correct for rigid body motion [J].
Bammer, Roland ;
Aksoy, Murat ;
Liu, Chunlei .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) :90-102
[6]   Matrix description of general motion correction applied to multishot images [J].
Batchelor, PG ;
Atkinson, D ;
Irarrazaval, P ;
Hill, DLG ;
Hajnal, J ;
Larkman, D .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1273-1280
[7]   A Randomized Trial of Intraarterial Treatment for Acute Ischemic Stroke [J].
Berkhemer, O. A. ;
Fransen, P. S. S. ;
Beumer, D. ;
van den Berg, L. A. ;
Lingsma, H. F. ;
Yoo, A. J. ;
Schonewille, W. J. ;
Vos, J. A. ;
Nederkoorn, P. J. ;
Wermer, M. J. H. ;
van Walderveen, M. A. A. ;
Staals, J. ;
Hofmeijer, J. ;
van Oostayen, J. A. ;
Nijeholt, G. J. Lycklama A. ;
Boiten, J. ;
Brouwer, P. A. ;
Emmer, B. J. ;
de Bruijn, S. F. ;
van Dijk, L. C. ;
Kappelle, L. J. ;
Lo, R. H. ;
Van Dijk, E. J. ;
de Vries, J. ;
de Kort, P. L. M. ;
van Rooij, W. J. J. ;
van den Berg, J. S. P. ;
van Hasselt, B. A. A. M. ;
Aerden, L. A. M. ;
Dallinga, R. J. ;
Visser, M. C. ;
Bot, J. C. J. ;
Vroomen, P. C. ;
Eshghi, O. ;
Schreuder, T. H. C. M. L. ;
Heijboer, R. J. J. ;
Keizer, K. ;
Tielbeek, A. V. ;
den Hertog, H. M. ;
Gerrits, D. G. ;
van den Berg-Vos, R. M. ;
Karas, G. B. ;
Steyerberg, E. W. ;
Flach, H. Z. ;
Marquering, H. A. ;
Sprengers, M. E. S. ;
Jenniskens, S. F. M. ;
Beenen, L. F. M. ;
van den Berg, R. ;
Koudstaal, P. J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (01) :11-20
[8]   Highly accelerated multishot echo planar imaging through synergistic machine learning and joint reconstruction [J].
Bilgic, Berkin ;
Chatnuntawech, Itthi ;
Manhard, Mary Kate ;
Tian, Qiyuan ;
Liao, Congyu ;
Iyer, Siddharth S. ;
Cauley, Stephen F. ;
Huang, Susie Y. ;
Polimeni, Jonathan R. ;
Wald, Lawrence L. ;
Setsompop, Kawin .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) :1343-1358
[9]   Wave-CAIPI for highly accelerated 3D imaging [J].
Bilgic, Berkin ;
Gagoski, Borjan A. ;
Cauley, Stephen F. ;
Fan, Audrey P. ;
Polimeni, Jonathan R. ;
Grant, P. Ellen ;
Wald, Lawrence L. ;
Setsompop, Kawin .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) :2152-2162
[10]   Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA) [J].
Breuer, FA ;
Blaimer, M ;
Mueller, MF ;
Seiberlich, N ;
Heidemann, RM ;
Griswold, MA ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :549-556