Direct measurement of the instantaneous linewidth of rapidly wavelength-swept lasers

被引:43
作者
Biedermann, Benjamin R. [1 ]
Wieser, Wolfgang [1 ]
Eigenwillig, Christoph M. [1 ]
Klein, Thomas [1 ]
Huber, Robert [1 ]
机构
[1] Univ Munich, Fak Phys, Lehrstuhl BioMol, D-80538 Munich, Germany
关键词
OPTICAL COHERENCE TOMOGRAPHY; MODE-LOCKED LASERS;
D O I
10.1364/OL.35.003733
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The instantaneous linewidth of rapidly wavelength-swept laser sources as used for optical coherence tomography (OCT) is of crucial interest for a deeper understanding of physical effects involved in their operation. Swept lasers for OCT, typically sweeping over similar to 15 THz in similar to 10 mu s, have linewidths of several gigahertz. The high optical-frequency sweep speed makes it impossible to measure the instantaneous spectrum with standard methods. Hence, up to now, experimental access to the instantaneous linewidth was rather indirect by the inverse Fourier transform of the coherence decay. In this Letter, we present a method by fast synchronous time gating and extraction of a "snapshot" of the instantaneous spectrum with an electro-optic modulator, which can subsequently be measured with an optical spectrum analyzer. This new method is analyzed in detail, and systematic artifacts, such as sideband generation due to the modulation and residual wavelength uncertainty due to the sweeping operation, are quantified. The method is checked for consistency with results from the common, more indirect measurement via coherence properties. (C) 2010 Optical Society of America
引用
收藏
页码:3733 / 3735
页数:3
相关论文
共 12 条
[1]   Photothermal detection of gold nanoparticles using phase-sensitive optical coherence tomography [J].
Adler, Desmond C. ;
Huang, Shu-Wei ;
Huber, Robert ;
Fujimoto, James G. .
OPTICS EXPRESS, 2008, 16 (07) :4376-4393
[2]   Quantitative upper airway imaging with anatomic optical coherence tomography [J].
Armstrong, JJ ;
Leigh, MS ;
Sampson, DD ;
Walsh, JH ;
Hillman, DR ;
Eastwood, PR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 173 (02) :226-233
[3]   Dispersion, coherence and noise of Fourier domain mode locked lasers [J].
Biedermann, Benjamin R. ;
Wieser, Wolfgang ;
Eigenwillig, Christoph M. ;
Klein, Thomas ;
Huber, Robert .
OPTICS EXPRESS, 2009, 17 (12) :9947-9961
[4]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[5]   Anterior segment imaging with Spectral OCT system using a high-speed CMOS camera [J].
Grulkowski, Ireneusz ;
Gora, Michalina ;
Szkulmowski, Maciej ;
Gorczynska, Iwona ;
Szlag, Daniel ;
Marcos, Susana ;
Kowalczyk, Andrzej ;
Wojtkowski, Maciej .
OPTICS EXPRESS, 2009, 17 (06) :4842-4858
[6]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[7]   Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography [J].
Huber, R ;
Wojtkowski, M ;
Fujimoto, JG .
OPTICS EXPRESS, 2006, 14 (08) :3225-3237
[8]   Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles [J].
Huber, R ;
Wojtkowski, M ;
Taira, K ;
Fujimoto, JG ;
Hsu, K .
OPTICS EXPRESS, 2005, 13 (09) :3513-3528
[9]   A theoretical description of Fourier domain mode locked lasers [J].
Jirauschek, Christian ;
Biedermann, Benjamin ;
Huber, Robert .
OPTICS EXPRESS, 2009, 17 (26) :24013-24019
[10]   High speed engine gas thermometry by Fourier-domain mode-locked laser absorption spectroscopy [J].
Kranendonk, Laura A. ;
An, Xinliang ;
Caswell, Andrew W. ;
Herold, Randy E. ;
Sanders, Scott T. ;
Huber, Robert ;
Fujimoto, James G. ;
Okura, Yasuhiro ;
Urata, Yasuhiro .
OPTICS EXPRESS, 2007, 15 (23) :15115-15128