A radiological analysis of the difference between MRI- and CT-based patient-specific matched guides for total knee arthroplasty from the same manufacturer A RANDOMISED CONTROLLED TRIAL

被引:19
作者
Schotanus, M. G. M. [1 ]
Sollie, R. [2 ,3 ]
van Haaren, E. H. [1 ]
Hendrickx, R. P. M. [1 ]
Jansen, E. J. P. [1 ]
Kort, N. P. [1 ]
机构
[1] Zuyderland Med Ctr, Dept Orthopaed Surg, Dr H van der Hoffpl 1, NL-6162 BG Sittard Geleen, Netherlands
[2] Zuyderland Med Ctr, Dr H van der Hoffpl 1, NL-6162 BG Sittard Geleen, Netherlands
[3] Sint Maartensklin, Dept Orthopaed Surg, Hengstdal 3, NL-6574 NA Ubbergen, Netherlands
关键词
COMPUTER-ASSISTED SURGERY; INSTRUMENTATION; ALIGNMENT; ACCURACY; TKA;
D O I
10.1302/0301-620X.98B6.36633
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims This prospective randomised controlled trial was designed to evaluate the outcome of both the MRI- and CT-based patient-specific matched guides (PSG) from the same manufacturer. Patients and Methods A total of 137 knees in 137 patients (50 men, 87 women) were included, 67 in the MRI- and 70 in the CT-based PSG group. Their mean age was 68.4 years (47.0 to 88.9). Outcome was expressed as the biomechanical limb alignment (centre hip-knee-ankle: HKA-axis) achieved post-operatively, the position of the individual components within 3 degrees of the pre-operatively planned alignment, correct planned implant size and operative data (e. g. operating time and blood loss). Results The patient demographics (e. g. age, body mass index), correct planned implant size and operative data were not significantly different between the two groups. The proportion of outliers in the coronal and sagittal plane ranged from 0% to 21% in both groups. Only the number of outliers for the posterior slope of the tibial component showed a significant difference (p = 0.004) with more outliers in the CT group (n = 9, 13%) than in the MRI group (0%). Conclusion The post-operative HKA-axis was comparable in the MRI- and CT-based PSGs, but there were significantly more outliers for the posterior slope in the CT-based PSGs.
引用
收藏
页码:786 / 792
页数:7
相关论文
共 39 条
[1]  
[Anonymous], KNEE SURG SPORTS TRA
[2]  
[Anonymous], KNEE SURG SPORTS TRA
[3]  
[Anonymous], ORTHOP CLIN N AM
[4]  
[Anonymous], KNEE
[5]   Comparison of MRI- and CT-based patient-specific guides for total knee arthroplasty [J].
Asada, Shigeki ;
Mori, Shigeshi ;
Matsushita, Tetsunao ;
Nakagawa, Koichi ;
Tsukamoto, Ichiroh ;
Akagi, Masao .
KNEE, 2014, 21 (06) :1238-1243
[6]   The effect of component malalignment on the clinical and radiological outcome of the Kinemax total knee replacement [J].
Bankes, MJK ;
Back, DL ;
Cannon, SR ;
Briggs, TWR .
KNEE, 2003, 10 (01) :55-60
[7]   Patient specific cutting blocks are currently of no proven value [J].
Barrack, R. L. ;
Ruh, E. L. ;
Williams, B. M. ;
Ford, A. D. ;
Foreman, K. ;
Nunley, R. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11) :95-99
[8]   In-Vivo Alignment Comparing Patient Specific Instrumentation with both Conventional and Computer Assisted Surgery (CAS) Instrumentation in Total Knee Arthroplasty [J].
Barrett, William ;
Hoeffel, Daniel ;
Dalury, David ;
Mason, J. Bohannon ;
Murphy, Jeff ;
Himden, Sam .
JOURNAL OF ARTHROPLASTY, 2014, 29 (02) :343-347
[9]   Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Zurakowski, D ;
Grifka, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05) :682-687
[10]   The Chitranjan Ranawat Award: Is Neutral Mechanical Alignment Normal for All Patients?: The Concept of Constitutional Varus [J].
Bellemans, Johan ;
Colyn, William ;
Vandenneucker, Hilde ;
Victor, Jan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (01) :45-53