Surgical treatment of tibial plateau fracture in elderly patients

被引:53
作者
Hsu, CJ [1 ]
Chang, WN [1 ]
Wong, CY [1 ]
机构
[1] Vet Gen Hosp, Orthopaed Sect, Kaohsiung, Taiwan
关键词
Cane; Total Knee Arthroplasty; Joint Space; Internal Fixation; Open Reduction;
D O I
10.1007/s004020000145
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This retrospective study involves 22 patients with displaced tibial plateau fractures who were treated surgically from July 1993 to April 1996. All the patients were over 60 years old (mean 66.3 years old, range 61-80 years). All of the patients were treated by open reduction and internal fixation with AO/ASIF buttress plates (Synthes, Bochum, Switzerland). Additional small fragment plate or inter-fragmental screws were used in some of them as indicated. Two patients died during follow-up of causes unrelated to the fractures. The average followup time was 49.8 months (range 36-68 months). The other 20 patients were interviewed at the outpatient clinic, and radiographs of bilateral standing knees were taken. By comparison with the uninjured side on radiographs, condylar joint space depression was noted in 6 patients. However, joint depression greater than 4 mm was not found. Malalignment with varus or valgus greater than 5 deg was not demonstrated in any case. Their range of motion was restored in all patients, with more than 120 deg of flexion and without extension lag except for the one who suffered a superficial wound infection. No complication required further surgical management. During the period of follow-up, no accelerated degenerative change in the operated knee joint resulted in total knee arthroplasty, Two patients needed occasional medical treatment for residual knee joint pain. Only two patients needed canes for assistance during walking due to old age and minor stroke. The results justify surgical treatment for displaced tibial plateau fractures in elderly patients.
引用
收藏
页码:67 / 70
页数:4
相关论文
共 12 条
[1]   THE RESULTS OF SURGICAL-MANAGEMENT OF DISPLACED TIBIAL PLATEAU FRACTURES IN THE ELDERLY [J].
BIYANI, A ;
REDDY, NS ;
CHAUDHURY, J ;
SIMISON, AJM ;
KLENERMAN, L .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (05) :291-297
[2]  
HARALD T, 1993, CLIN ORTHOPAEDICS, V292, P87
[3]  
HONKONEN SE, 1994, CLIN ORTHOP RELAT R, P199
[4]   Use of arthroscopy and interporous hydroxyapatite as a bone graft substitute in tibial plateau fractures [J].
Itokazu, M ;
Matsunaga, T ;
Ishii, M ;
Kusakabe, H ;
Wyni, Y .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1996, 115 (01) :45-48
[5]   EXTERNAL FIXATION AND LIMITED INTERNAL-FIXATION FOR COMPLEX FRACTURES OF THE TIBIAL PLATEAU [J].
MARSH, JL ;
SMITH, ST ;
DO, TT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (05) :661-673
[6]   TIBIAL CONDYLAR FRACTURES - IMPAIRMENT OF KNEE-JOINT STABILITY AS AN INDICATION FOR SURGICAL TREATMENT [J].
RASMUSSEN, PS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (07) :1331-1350
[7]  
Rockwood CA, 1991, ROCKWOOD GREENS FRAC, P1728
[8]  
Schatzker J., 1992, SKELETAL TRAUMA FRAC, V2, P1745
[9]  
SEGAL D, 1993, CLIN ORTHOP RELAT R, P232
[10]  
SEPPO EH, 1995, J ORTHOP TRAUMA, V9, P273