High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI

被引:65
|
作者
Zhu, Chengcheng [1 ]
Haraldsson, Henrik [1 ]
Tian, Bing [1 ]
Meisel, Karl [2 ]
Ko, Nerissa [2 ]
Lawton, Michael [3 ]
Grinstead, John [4 ]
Ahn, Sinyeob [4 ]
Laub, Gerhard [4 ]
Hess, Christopher [1 ,2 ]
Saloner, David [1 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94121 USA
[2] Univ Calif San Francisco, Dept Neurol, San Francisco, CA 94121 USA
[3] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94121 USA
[4] Siemens Healthcare, San Francisco, CA USA
[5] VA Med Ctr, Serv Radiol, San Francisco, CA USA
关键词
Intracranial vessel wall; Atherosclerosis; Aneurysm; High resolution MRI; Contrast enhancement; CONTRAST-ENHANCED MRI; BLACK BLOOD MRI; CAROTID-ARTERY; TESLA; SUPPRESSION; ANEURYSMS; DISEASE;
D O I
10.1007/s10334-016-0531-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High resolution MRI of the intracranial vessel wall provides important insights in the assessment of intracranial vascular disease. This study aims to refine high resolution 3D MRI techniques for intracranial vessel wall imaging at both 3 and 7 T using customized flip angle train design, and to explore their comparative abilities. 11 patients with intracranial artery disease (four atherosclerotic plaques, six aneurysms and one reversible cerebral vasoconstriction syndrome) were imaged at 3 and 7 T with a 3D T (1)-weighted fast-spin-echo sequence (SPACE) both pre and post Gd contrast injection. Wall to lumen contrast ratio (CRwall-lumen), contrast enhancement ratio (ER) and the sharpness of the vessel wall were quantified. Two experienced radiologists evaluated the image quality on a 0-5 scale. Both 3 and 7 T achieved good image quality with high resolution (nominal 0.5 mm isotropic) and whole brain coverage. The CRwall-lumen and the ER measurements were comparable (p > 0.05). The 7 T images were significantly sharper (sharpness: 2.69 +/- 0.50 vs. 1.88 +/- 0.53 mm(-1), p < 0.001) with higher image quality (reader 1 score: 3.5 +/- 1.1 vs. 2.4 +/- 1.1, p = 0.002) compared to 3 T. 3D T (1)-weighted SPACE can be used for intracranial vessel wall evaluation at both 3 and 7 T. 7 T provides significantly better image quality and improves the confidence of diagnosis.
引用
收藏
页码:559 / 570
页数:12
相关论文
共 50 条
  • [21] Intracranial Vessel Segmentation in 3D High-Resolution T1 Black-Blood MRI
    Elsheikh, S.
    Urbach, H.
    Reisert, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (12) : 1719 - 1721
  • [22] T2 quantification in brain using 3D fast spin-echo imaging with long echo trains
    Snyder, Jeff
    McPhee, Kelly C.
    Wilman, Alan H.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2145 - 2160
  • [23] Novel Imaging Technique For Evaluation of Carotid Stenosis Using MRI with 3D Fast- Spin- Echo
    Kan, Issei
    Ishibashi, Toshihiro
    Shibuya, Kazunori
    Kitagawa, Hisashi
    Kaito, Nobuki
    Murayama, Yuichi
    Abe, Toshiaki
    STROKE, 2013, 44 (02)
  • [24] High-resolution 3D T2-weighted fast spin echo: new applications in the orbit
    Simon, EM
    McCaffery, S
    Rowley, HA
    Fischbein, NJ
    Shimikawa, A
    O'Brien, JM
    NEURORADIOLOGY, 2003, 45 (07) : 489 - 492
  • [25] High-resolution 3D T2-weighted fast spin echo: new applications in the orbit
    Erin M. Simon
    Sharon McCaffery
    Howard A. Rowley
    Nancy J. Fischbein
    Ann Shimikawa
    Joan M. O'Brien
    Neuroradiology, 2003, 45 : 489 - 492
  • [26] Comparison of parallel MRI reconstruction methods for accelerated 3D fast spin-echo imaging
    Xiao, Zhikui
    Hoge, W. Scott
    Mulkern, R. V.
    Zhao, Lei
    Hu, Guangshu
    Kyriakos, Walid E.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 650 - 660
  • [27] Blood Flow Mimicking Aneurysmal Wall Enhancement: A Diagnostic Pitfall of Vessel Wall MRI Using the Postcontrast 3D Turbo Spin-Echo MR Imaging Sequence
    Kalsoum, E.
    Negrier, A. Chabernaud
    Tuilier, T.
    Benaissa, A.
    Blanc, R.
    Gallas, S.
    Lefaucheur, J. -P.
    Gaston, A.
    Lopes, R.
    Brugieres, P.
    Hodel, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (06) : 1065 - 1067
  • [28] Fast 3D large-angle spin-echo imaging (3D FLASE)
    Ma, JF
    Wehrli, FW
    Song, HK
    MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (06) : 903 - 910
  • [29] Use of 3D perfusion imaging and 3D fast spin echo for evaluation of prostate carcinoma
    Bradley, WG
    Yeh, MM
    Chen, D
    Baghdassarian, R
    Baronofsky, ID
    O'Malley, PJ
    RADIOLOGY, 2001, 221 : 584 - 584
  • [30] Visualizing wall enhancement over time in unruptured intracranial aneurysms using 3D vessel wall imaging
    Tian, Bing
    Toossi, Shahed
    Eisenmenger, Laura
    Faraji, Farshid
    Ballweber, Megan K.
    Josephson, S. Andrew
    Haraldsson, Henrik
    Zhu, Chengcheng
    Ahn, Sinyeob
    Laub, Gerhard
    Hess, Christopher
    Saloner, David
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (01) : 193 - 200