High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI

被引:65
|
作者
Zhu, Chengcheng [1 ]
Haraldsson, Henrik [1 ]
Tian, Bing [1 ]
Meisel, Karl [2 ]
Ko, Nerissa [2 ]
Lawton, Michael [3 ]
Grinstead, John [4 ]
Ahn, Sinyeob [4 ]
Laub, Gerhard [4 ]
Hess, Christopher [1 ,2 ]
Saloner, David [1 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94121 USA
[2] Univ Calif San Francisco, Dept Neurol, San Francisco, CA 94121 USA
[3] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94121 USA
[4] Siemens Healthcare, San Francisco, CA USA
[5] VA Med Ctr, Serv Radiol, San Francisco, CA USA
关键词
Intracranial vessel wall; Atherosclerosis; Aneurysm; High resolution MRI; Contrast enhancement; CONTRAST-ENHANCED MRI; BLACK BLOOD MRI; CAROTID-ARTERY; TESLA; SUPPRESSION; ANEURYSMS; DISEASE;
D O I
10.1007/s10334-016-0531-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High resolution MRI of the intracranial vessel wall provides important insights in the assessment of intracranial vascular disease. This study aims to refine high resolution 3D MRI techniques for intracranial vessel wall imaging at both 3 and 7 T using customized flip angle train design, and to explore their comparative abilities. 11 patients with intracranial artery disease (four atherosclerotic plaques, six aneurysms and one reversible cerebral vasoconstriction syndrome) were imaged at 3 and 7 T with a 3D T (1)-weighted fast-spin-echo sequence (SPACE) both pre and post Gd contrast injection. Wall to lumen contrast ratio (CRwall-lumen), contrast enhancement ratio (ER) and the sharpness of the vessel wall were quantified. Two experienced radiologists evaluated the image quality on a 0-5 scale. Both 3 and 7 T achieved good image quality with high resolution (nominal 0.5 mm isotropic) and whole brain coverage. The CRwall-lumen and the ER measurements were comparable (p > 0.05). The 7 T images were significantly sharper (sharpness: 2.69 +/- 0.50 vs. 1.88 +/- 0.53 mm(-1), p < 0.001) with higher image quality (reader 1 score: 3.5 +/- 1.1 vs. 2.4 +/- 1.1, p = 0.002) compared to 3 T. 3D T (1)-weighted SPACE can be used for intracranial vessel wall evaluation at both 3 and 7 T. 7 T provides significantly better image quality and improves the confidence of diagnosis.
引用
收藏
页码:559 / 570
页数:12
相关论文
共 50 条
  • [1] High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI
    Chengcheng Zhu
    Henrik Haraldsson
    Bing Tian
    Karl Meisel
    Nerissa Ko
    Michael Lawton
    John Grinstead
    Sinyeob Ahn
    Gerhard Laub
    Christopher Hess
    David Saloner
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 559 - 570
  • [2] Neural network enhanced 3D turbo spin echo for MR intracranial vessel wall imaging
    Zhou, Zechen
    Chen, Shuo
    Balu, Niranjan
    Chu, Baocheng
    Zhao, Xihai
    Sun, Jie
    Mossa-Basha, Mahmud
    Hatsukami, Thomas
    Boernert, Peter
    Yuan, Chun
    MAGNETIC RESONANCE IMAGING, 2021, 78 : 7 - 17
  • [3] High-resolution intracranial vessel wall imaging using 3D CUBE T1 weighted sequence
    Li, Min-Li
    Xu, Yu-Yuan
    Hou, Bo
    Sun, Zhao-Yong
    Zhou, Hai-Long
    Jin, Zheng-Yu
    Feng, Feng
    Xu, Wei-Hai
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (04) : 803 - 807
  • [4] Longitudinal Study of Intracranial Atherosclerosis Using 3D High Resolution MRI Imaging
    Zhang, Xuefeng
    Yang, Huan
    Shahriari, Mona
    Liu, Li
    Zhang, Yiyi
    Guallar, Eliseo
    Wasserman, Bruce
    Qiao, Ye
    STROKE, 2017, 48
  • [5] Optimized Inner-Volume 3D TSE for High-Resolution Vessel Wall Imaging of Intracranial Perforating Arteries at 7T
    Kong, Qingle
    Wu, Yue
    Weng, Dehe
    An, Jing
    Zhuo, Yan
    Zhang, Zihao
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [6] Intracranial black-blood MR angiography with high-resolution 3D fast spin echo
    Alexander, AL
    Buswell, HR
    Sun, Y
    Chapman, BE
    Tsuruda, TS
    Parker, DL
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (02) : 298 - 310
  • [7] Comparison of 7 T and 3 T vessel wall MRI for the evaluation of intracranial aneurysm wall
    Feng, Junqiang
    Liu, Xinke
    Zhang, Zihao
    Wu, Yue
    Li, Zhixin
    Zhang, Qiang
    Jiang, Yuhua
    You, Wei
    Liu, Peng
    Wang, Yan
    Mossa-Basha, Mahmud
    Saloner, David
    Li, Youxiang
    Zhu, Chengcheng
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2384 - 2392
  • [8] Motion-compensated 3D turbo spin-echo for more robust MR intracranial vessel wall imaging
    Hu, Zhehao
    van der Kouwe, Andre
    Han, Fei
    Xiao, Jiayu
    Chen, Junzhou
    Han, Hui
    Bi, Xiaoming
    Li, Debiao
    Fan, Zhaoyang
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (02) : 637 - 647
  • [9] Comparison of 7 T and 3 T vessel wall MRI for the evaluation of intracranial aneurysm wall
    Junqiang Feng
    Xinke Liu
    Zihao Zhang
    Yue Wu
    Zhixin Li
    Qiang Zhang
    Yuhua Jiang
    Wei You
    Peng Liu
    Yan Wang
    Mahmud Mossa-Basha
    David Saloner
    Youxiang Li
    Chengcheng Zhu
    European Radiology, 2022, 32 : 2384 - 2392
  • [10] Whole-Brain Intracranial Vessel Wall Imaging at 3 Tesla Using Cerebrospinal Fluid-Attenuated T1-Weighted 3D Turbo Spin Echo
    Fan, Zhaoyang
    Yang, Qi
    Deng, Zixin
    Li, Yuxia
    Bi, Xiaoming
    Song, Shlee
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1142 - 1150