High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI

被引:65
作者
Zhu, Chengcheng [1 ]
Haraldsson, Henrik [1 ]
Tian, Bing [1 ]
Meisel, Karl [2 ]
Ko, Nerissa [2 ]
Lawton, Michael [3 ]
Grinstead, John [4 ]
Ahn, Sinyeob [4 ]
Laub, Gerhard [4 ]
Hess, Christopher [1 ,2 ]
Saloner, David [1 ,5 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94121 USA
[2] Univ Calif San Francisco, Dept Neurol, San Francisco, CA 94121 USA
[3] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94121 USA
[4] Siemens Healthcare, San Francisco, CA USA
[5] VA Med Ctr, Serv Radiol, San Francisco, CA USA
关键词
Intracranial vessel wall; Atherosclerosis; Aneurysm; High resolution MRI; Contrast enhancement; CONTRAST-ENHANCED MRI; BLACK BLOOD MRI; CAROTID-ARTERY; TESLA; SUPPRESSION; ANEURYSMS; DISEASE;
D O I
10.1007/s10334-016-0531-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High resolution MRI of the intracranial vessel wall provides important insights in the assessment of intracranial vascular disease. This study aims to refine high resolution 3D MRI techniques for intracranial vessel wall imaging at both 3 and 7 T using customized flip angle train design, and to explore their comparative abilities. 11 patients with intracranial artery disease (four atherosclerotic plaques, six aneurysms and one reversible cerebral vasoconstriction syndrome) were imaged at 3 and 7 T with a 3D T (1)-weighted fast-spin-echo sequence (SPACE) both pre and post Gd contrast injection. Wall to lumen contrast ratio (CRwall-lumen), contrast enhancement ratio (ER) and the sharpness of the vessel wall were quantified. Two experienced radiologists evaluated the image quality on a 0-5 scale. Both 3 and 7 T achieved good image quality with high resolution (nominal 0.5 mm isotropic) and whole brain coverage. The CRwall-lumen and the ER measurements were comparable (p > 0.05). The 7 T images were significantly sharper (sharpness: 2.69 +/- 0.50 vs. 1.88 +/- 0.53 mm(-1), p < 0.001) with higher image quality (reader 1 score: 3.5 +/- 1.1 vs. 2.4 +/- 1.1, p = 0.002) compared to 3 T. 3D T (1)-weighted SPACE can be used for intracranial vessel wall evaluation at both 3 and 7 T. 7 T provides significantly better image quality and improves the confidence of diagnosis.
引用
收藏
页码:559 / 570
页数:12
相关论文
共 24 条
[1]   Unruptured intracranial aneurysms: epidemiology, natural history, management options, and familial screening [J].
Brown, Robert D., Jr. ;
Broderick, Jrioseph P. .
LANCET NEUROLOGY, 2014, 13 (04) :393-404
[2]   Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo [J].
Busse, Reed F. ;
Brau, Anja C. S. ;
Vu, Anthony ;
Michelich, Charles R. ;
Bayram, Ersin ;
Kijowski, Richard ;
Reeder, Scott B. ;
Rowley, Howard A. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :640-649
[3]  
Busse RF, 2006, P INT SOC MAG RESON, V14, P2430
[4]   Does Aneurysmal Wall Enhancement on Vessel Wall MRI Help to Distinguish Stable From Unstable Intracranial Aneurysms? [J].
Edjlali, Myriam ;
Gentric, Jean-Christophe ;
Regent-Rodriguez, Christine ;
Trystram, Denis ;
Ben Hassen, Wajih ;
Lion, Stephanie ;
Nataf, Francois ;
Raymond, Jean ;
Wieben, Oliver ;
Turski, Patrick ;
Meder, Jean-Francois ;
Oppenheim, Catherine ;
Naggara, Olivier .
STROKE, 2014, 45 (12) :3704-3706
[5]  
Feiweier T, 2006, US Patent, Patent No. [US7038453 B2, 7038453]
[6]   Large artery intracranial occlusive disease - A large worldwide burden but a relatively neglected frontier [J].
Gorelick, Philip B. ;
Wong, Ka Sing ;
Bae, Hee-Joon ;
Pandey, Dilip K. .
STROKE, 2008, 39 (08) :2396-2399
[7]   Variable Flip Angle Three-Dimensional Fast Spin-Echo Sequence Combined With Outer Volume Suppression for Imaging Trabecular Bone Structure of the Proximal Femur [J].
Han, Misung ;
Chiba, Ko ;
Banerjee, Suchandrima ;
Carballido-Gamio, Julio ;
Krug, Roland .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (05) :1300-1310
[8]  
Harteveld AA, 2015, AM J NEURORADIOL, DOI [10.3174/anjr.A4628, DOI 10.3174/ANJR.A4628]
[9]   Visualization of the Aneurysm Wall: A 7.0-Tesla Magnetic Resonance Imaging Study [J].
Kleinloog, Rachel ;
Korkmaz, Emine ;
Zwanenburg, Jaco J. M. ;
Kuijf, Hugo J. ;
Visser, Fredy ;
Blankena, Roos ;
Post, Jan A. ;
Ruigrok, Ynte M. ;
Luijten, Peter R. ;
Regli, Luca ;
Rinkel, Gabriel J. E. ;
Verweij, Bon H. .
NEUROSURGERY, 2014, 75 (06) :614-622
[10]   MRI of the Carotid Artery at 7 Tesla: Quantitative Comparison With 3 Tesla [J].
Koning, Wouter ;
de Rotte, Alexandra A. J. ;
Bluemink, Johanna J. ;
van der Velden, Tijl A. ;
Luijten, Peter R. ;
Klomp, Dennis W. J. ;
Zwanenburg, Jaco J. M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (03) :773-780