Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears

被引:1
作者
Zhang Chun-gang [1 ]
Zhao De-wei [1 ]
Wang Wei-ming [1 ]
Ren Ming-fa [2 ]
Li Rui-xin [1 ]
Yang Sheng [1 ]
Liu Yu-peng [1 ]
机构
[1] Dalian Univ Technol, Affiliated Zhongshan Hosp, Dept Orthoped, Dalian 116001, Liaoning, Peoples R China
[2] Dalian Univ Technol, State Key Lab Struct Anal Ind Equipment, Dalian 116001, Liaoning, Peoples R China
关键词
biomechanics; rotator cuff; suture anchor; INFERIOR GLENOHUMERAL LIGAMENT; SUPRASPINATUS TENDON TEARS; PARTIAL-THICKNESS TEARS; ARTHROSCOPIC REPAIR; ANTERIOR BAND; IN-VITRO; ARTHROGRAPHY; FIXATION; STRENGTH; POSITION;
D O I
10.3760/cmaj.issn.0366-6999.2010.21.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. Methods In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of <= 45 degrees into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Results Gap formation for the transtendon single-row repair was significantly smaller (P <0.05) when compared with the double-row repair for the first cycle ((1.74+/-0.38) mm vs. (2.86+/-0.46) mm, respectively) and the last cycle ((3.77+/-0.45) mm vs. (5.89+/-0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P <0.05) when compared with the double-row repair. Also, it had a higher mean ultimate tensile load and stiffness. Conclusions For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation. Chin Med J 2010;123(21):3049-3054
引用
收藏
页码:3049 / 3054
页数:6
相关论文
共 50 条
  • [31] Arthroscopic knotless single-row repair preserving full footprint versus tear completion repair for partial articular-sided rotator cuff tear
    Liu, Cen Tao
    Ge, Heng An
    Hu, Rui
    Huang, Jing Biao
    Cheng, Yi Chao
    Wang, Min
    Wu, Peng
    Cheng, Biao
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (02)
  • [32] Single-row Versus Double-row Repair of the Distal Achilles Tendon: A Biomechanical Comparison
    Pilson, Holly
    Brown, Philip
    Stitzel, Joel
    Scott, Aaron
    JOURNAL OF FOOT & ANKLE SURGERY, 2012, 51 (06) : 762 - 766
  • [33] Single versus double-row repair of the rotator cuff Does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?
    Pauly, Stephan
    Gerhardt, Christian
    Chen, Jianhai
    Scheibel, Markus
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (12) : 1718 - 1729
  • [34] Outcomes of Single-Row and Double-Row Arthroscopic Rotator Cuff Repair: A Systematic Review
    Saridakis, Paul
    Jones, Grant
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (03) : 732 - 742
  • [35] Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model
    Goschka, Andrew M.
    Hafer, Jason S.
    Reynolds, Kirk A.
    Aberle, Nicholas S., II
    Baldini, Todd H.
    Hawkins, Monica J.
    McCarty, Eric C.
    CLINICAL BIOMECHANICS, 2015, 30 (08) : 808 - 813
  • [36] Meta-analysis comparing single-row and double-row repair techniques in the arthroscopic treatment of rotator cuff tears
    Xu, Caiqi
    Zhao, Jinzhong
    Li, Dingfeng
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (02) : 182 - 188
  • [37] Comparable Biomechanical Results for a Modified Single-Row Rotator Cuff Reconstruction Using Triple-Loaded Suture Anchors Versus a Suture-Bridging Double-Row Repair
    Lorbach, Olaf
    Kieb, Matthias
    Raber, Florian
    Busch, Lueder C.
    Kohn, Dieter
    Pape, Dietrich
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (02) : 178 - 187
  • [38] Single-Row or Double-Row Fixation Technique for Full-Thickness Rotator Cuff Tears: A Meta-Analysis
    Zhang, Qiang
    Ge, Heng'an
    Zhou, Jiaojiao
    Yuan, Chaoqun
    Chen, Kai
    Cheng, Biao
    PLOS ONE, 2013, 8 (07):
  • [39] Comparison of single versus double-row techniques in arthroscopic rotator cuff repair of full-thickness tears
    Dogar, Fatih
    Uzun, Erdal
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2021, 12 (04): : 422 - 427
  • [40] Simple Double-Row Rotator Cuff Repair Technique for Large and Massive Cuff Tears
    Funk, Lennard
    Auplish, Sunil
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2009, 10 (01) : 39 - 42