Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears

被引:1
|
作者
Zhang Chun-gang [1 ]
Zhao De-wei [1 ]
Wang Wei-ming [1 ]
Ren Ming-fa [2 ]
Li Rui-xin [1 ]
Yang Sheng [1 ]
Liu Yu-peng [1 ]
机构
[1] Dalian Univ Technol, Affiliated Zhongshan Hosp, Dept Orthoped, Dalian 116001, Liaoning, Peoples R China
[2] Dalian Univ Technol, State Key Lab Struct Anal Ind Equipment, Dalian 116001, Liaoning, Peoples R China
关键词
biomechanics; rotator cuff; suture anchor; INFERIOR GLENOHUMERAL LIGAMENT; SUPRASPINATUS TENDON TEARS; PARTIAL-THICKNESS TEARS; ARTHROSCOPIC REPAIR; ANTERIOR BAND; IN-VITRO; ARTHROGRAPHY; FIXATION; STRENGTH; POSITION;
D O I
10.3760/cmaj.issn.0366-6999.2010.21.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. Methods In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of <= 45 degrees into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Results Gap formation for the transtendon single-row repair was significantly smaller (P <0.05) when compared with the double-row repair for the first cycle ((1.74+/-0.38) mm vs. (2.86+/-0.46) mm, respectively) and the last cycle ((3.77+/-0.45) mm vs. (5.89+/-0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P <0.05) when compared with the double-row repair. Also, it had a higher mean ultimate tensile load and stiffness. Conclusions For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation. Chin Med J 2010;123(21):3049-3054
引用
收藏
页码:3049 / 3054
页数:6
相关论文
共 50 条
  • [21] Single-row modified Mason-Allen versus double-row arthroscopic rotator cuff repair: A biomechanical and surface area comparison
    Nelson, Cory O.
    Sileo, Michael J.
    Grossman, Mark G.
    Serra-Hsu, Frederick
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (08) : 941 - 948
  • [22] Suture spanning augmentation of single-row rotator cuff repair: a biomechanical analysis
    Early, Nicholas A.
    Elias, John J.
    Lippitt, Steven B.
    Filipkowski, Danielle E.
    Pedowitz, Robert A.
    Ciccone, William J., II
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (02) : 337 - 342
  • [23] Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study
    Carbonel, Ignacio
    Antonio Martinez, Angel
    Calvo, Angel
    Ripalda, Jorge
    Herrera, Antonio
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1877 - 1883
  • [24] Single-row versus double-row arthroscopic rotator cuff repair in small- to medium-sized tears
    Aydin, Nuri
    Kocaoglu, Baris
    Guven, Osman
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (05) : 722 - 725
  • [25] Single-Row Versus Double-Row Arthroscopic Rotator Cuff Repair: A Prospective Randomized Clinical Study
    Grasso, Andrea
    Milano, Giuseppe
    Salvatore, Matteo
    Falcone, Gianluca
    Deriu, Laura
    Fabbriciani, Carlo
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (01) : 4 - 12
  • [26] Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material
    M. H. Baums
    G. H. Buchhorn
    G. Spahn
    B. Poppendieck
    W. Schultz
    H.-M. Klinger
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 1052 - 1060
  • [27] Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material
    Baums, M. H.
    Buchhorn, G. H.
    Spahn, G.
    Poppendieck, B.
    Schultz, W.
    Klinger, H. -M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (11) : 1052 - 1060
  • [28] Clinical Outcomes of Double-Row Versus Single-Row Rotator Cuff Repairs
    Wall, Lindley B.
    Keener, Jay D.
    Brophy, Robert H.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (11) : 1312 - 1318
  • [29] Biomechanical Analysis of a Knotless Transtendon Interimplant Mattress Repair for Partial-Thickness Articular-Sided Rotator Cuff Tears
    Park, Maxwell C.
    Jun, Bong J.
    Park, Chong J.
    Oh, Joo H.
    Lee, Thay Q.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (12) : 2427 - 2434
  • [30] Single-Versus Double-Row Arthroscopic Rotator Cuff Repair in Massive Tears
    Wang, EnZhi
    Wang, Liang
    Gao, Peng
    Li, ZhongJi
    Zhou, Xiao
    Wang, SongGang
    MEDICAL SCIENCE MONITOR, 2015, 21 : 1556 - 1561