Energy and economic performance analysis of an open cycle solar desiccant dehumidification air-conditioning system for application in Hong Kong

被引:54
作者
Li, Yutong [1 ]
Lu, Lin [1 ]
Yang, Hongxing [1 ]
机构
[1] Hong Kong Polytech Univ, RERG, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Solar desiccant dehumidification; Energy performance; Economical analysis; VAPOR-COMPRESSION; FEASIBILITY; SIMULATION;
D O I
10.1016/j.solener.2010.09.006
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this article, a transient simulation model and the EnergyPlus were used to study the energy performance and economical feasibility for integrating a solar liquid desiccant dehumidification system with a conventional vapor compression air-conditioning system for the weather condition of Hong Kong The vapor compression system capacity in the solar assisted air-conditioning system can be reduced to 19 kW from original 28 kW of a conventional air conditioning system as a case study due to the solar desiccant cooling The economical performance of the solar desiccant dehumidification system is compared with that of the conventional air-conditioning system The results show that the energy saving potentials due to incorporation of the solar desiccant dehumidification system in a traditional air-conditioning system is significant for the hot wet weather in Hong Kong due to higher COP resulted from higher supply chilled water temperature from chiller plants The annual operation energy savings for the hybrid system is 6760 kWh and the payback period of the hybrid system is around 7 years The study shows that the solar assisted air-conditioning is a viable technology for utilizations in subtropical areas (C) 2010 Elsevier Ltd All rights reserved
引用
收藏
页码:2085 / 2095
页数:11
相关论文
共 19 条
[1]   Generation of a typical meteorological year for Hong Kong [J].
Chan, ALS ;
Chow, TT ;
Fong, SKF ;
Lin, JZ .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (01) :87-96
[2]   PREDICTIONS OF MOISTURE REMOVAL EFFICIENCIES FOR PACKED-BED DEHUMIDIFICATION SYSTEMS [J].
CHUNG, TW .
GAS SEPARATION & PURIFICATION, 1994, 8 (04) :265-268
[3]   Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning [J].
Dai, YJ ;
Wang, RZ ;
Zhang, HF ;
Yu, JD .
APPLIED THERMAL ENGINEERING, 2001, 21 (12) :1185-1202
[4]  
Davanagere BS, 1999, INT J ENERG RES, V23, P103, DOI 10.1002/(SICI)1099-114X(199902)23:2<103::AID-ER440>3.0.CO
[5]  
2-I
[6]  
Davanagere BS, 1999, INT J ENERG RES, V23, P7, DOI 10.1002/(SICI)1099-114X(199901)23:1<7::AID-ER439>3.0.CO
[7]  
2-U
[8]  
Duffie J.A., 1994, Solar Engineering of Thermal Processes
[9]   Use of desiccant dehumidification to improve energy utilization in air-conditioning systems in Beirut [J].
Ghaddar, N ;
Ghali, K ;
Najm, A .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (15) :1317-1338
[10]   Energy savings potential of a hybrid desiccant dehumidification air conditioning system in Beirut [J].
Ghali, Kamel .