Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation

被引:36
作者
Ashkanfar, Ariyan [1 ]
Langton, David J. [2 ]
Joyce, Thomas J. [1 ]
机构
[1] Newcastle Univ, Sch Mech & Syst Engn, Stephenson Bldg,Claremont Rd, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[2] Univ Hosp North Tees, North Tees Explant Ctr, North Tees, England
关键词
Wear modelling; Finite element analysis; Total hip replacement; Taper junction; Surface roughness; ON-METAL BEARINGS; ARTHROPLASTY; CONTACT; TOPOGRAPHY; CORROSION; HARDNESS; COBALT; DEBRIS; ALLOY; IONS;
D O I
10.1016/j.jbiomech.2017.07.027
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The generation of particulate debris at the taper junction of total hip replacements (THRs), can cause failure of the artificial hip. The taper surfaces of femoral heads and trunnions of femoral stems are generally machined to a certain roughness to enhance fixation. However, the effect of the surface roughness of these surfaces on the fixation, wear and consequently clinical outcomes of the design is largely unknown. In this study, we asked whether a micro-grooved trunnion surface finish (1) improves the fixation and (2) reduces the wear rate at the taper junction of THRs. We used 3D finite element (FE) models of THRs to, firstly, investigate the effect of initial fixation of a Cobalt-Chromium femoral head with a smooth taper surface mated with a Titanium (1) micro-grooved and (2) smooth, trunnion surface finishes. Secondly, we used a computational FE wear model to compare the wear evolution between the models, which was then validated against wear measurements of the taper surface of explanted femoral heads. The fixation at the taper junction was found to be better for the smooth couplings. Over a 7 million load cycle analysis in-silico, the linear wear depth and the total material loss was around 3.2 and 1.4 times higher for the femoral heads mated with micro-grooved trunnions. It was therefore concluded that smooth taper and trunnion surfaces will provide better fixation at the taper junction and reduce the volumetric wear rates. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:47 / 54
页数:8
相关论文
共 26 条
  • [1] Ashkanfar A., 2017, J MECH BEHAV BIOMED
  • [2] Determining material loss from the femoral stem trunnion in hip arthroplasty using a coordinate measuring machine
    Bone, Martin C.
    Sidaginamale, Raghavendra P.
    Lord, James K.
    Scholes, Susan C.
    Joyce, Thomas J.
    Nargol, Anthony V. F.
    Langton, David J.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (01) : 69 - 76
  • [3] Shorter, rough trunnion surfaces are associated with higher taper wear rates than longer, smooth trunnion surfaces in a contemporary large head metal-on-metal total hip arthroplasty system
    Brock, Timothy M.
    Sidaginamale, Raghavendra
    Rushton, Steven
    Nargol, Antoni V. F.
    Bowsher, John G.
    Savisaar, Christina
    Joyce, Tom J.
    Deehan, David J.
    Lord, James K.
    Langton, David J.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (12) : 1868 - 1874
  • [4] Biomechanics of large femoral heads - What they do and don't do
    Crowninshield, RD
    Maloney, WJ
    Wentz, DH
    Humphrey, SM
    Blanchard, CR
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 102 - 107
  • [5] Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern
    Delaunay, C.
    Petit, I.
    Learmonth, I. D.
    Oger, P.
    Vendittoli, P. A.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (08) : 894 - 904
  • [6] Total hip arthroplasty head-neck contact mechanics: A stochastic investigation of key parameters
    Donaldson, Finn E.
    Coburn, James C.
    Siegel, Karen Lohmann
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (07) : 1634 - 1641
  • [7] Experimental and modelling aspects of abrasive wear of a A357 aluminium alloy under gross slip fretting conditions
    Elleuch, K
    Fouvry, S
    [J]. WEAR, 2005, 258 (1-4) : 40 - 49
  • [8] The effect of different assembly loads on taper junction fretting wear in total hip replacements
    English, Russell
    Ashkanfar, Ariyan
    Rothwell, Glynn
    [J]. TRIBOLOGY INTERNATIONAL, 2016, 95 : 199 - 210
  • [9] A computational approach to fretting wear prediction at the head-stem taper junction of total hip replacements
    English, Russell
    Ashkanfar, Ariyan
    Rothwell, Glynn
    [J]. WEAR, 2015, 338 : 210 - 220
  • [10] What is the Trouble With Trunnions?
    Esposito, Christina I.
    Wright, Timothy M.
    Goodman, Stuart B.
    Berry, Daniel J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (12) : 3652 - 3658