Generating synthetic CT from low-dose cone-beam CT by using generative adversarial networks for adaptive radiotherapy

被引:37
作者
Gao, Liugang [1 ,2 ]
Xie, Kai [1 ,2 ]
Wu, Xiaojin [3 ]
Lu, Zhengda [1 ,2 ,4 ]
Li, Chunying [1 ,2 ]
Sun, Jiawei [1 ,2 ]
Lin, Tao [1 ,2 ]
Sui, Jianfeng [1 ,2 ]
Ni, Xinye [1 ,2 ]
机构
[1] Nanjing Med Univ, Peoples Hosp Changzhou 2, Dept Radiotherapy, Changzhou 213003, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Ctr Med Phys, Changzhou 213003, Jiangsu, Peoples R China
[3] Xuzhou 1 Peoples Hosp, Oncol Dept, Xuzhou 221000, Jiangsu, Peoples R China
[4] Nanjing Med Univ, Sch Biomed Engn & Informat, Nanjing 213000, Peoples R China
关键词
Synthetic CT; Low-dose CBCT; Attention-guided GAN; Unpaired; Adaptive radiotherapy; SCATTER CORRECTION; RADIATION; FEASIBILITY;
D O I
10.1186/s13014-021-01928-w
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective To develop high-quality synthetic CT (sCT) generation method from low-dose cone-beam CT (CBCT) images by using attention-guided generative adversarial networks (AGGAN) and apply these images to dose calculations in radiotherapy. Methods The CBCT/planning CT images of 170 patients undergoing thoracic radiotherapy were used for training and testing. The CBCT images were scanned under a fast protocol with 50% less clinical projection frames compared with standard chest M20 protocol. Training with aligned paired images was performed using conditional adversarial networks (so-called pix2pix), and training with unpaired images was carried out with cycle-consistent adversarial networks (cycleGAN) and AGGAN, through which sCT images were generated. The image quality and Hounsfield unit (HU) value of the sCT images generated by the three neural networks were compared. The treatment plan was designed on CT and copied to sCT images to calculated dose distribution. Results The image quality of sCT images by all the three methods are significantly improved compared with original CBCT images. The AGGAN achieves the best image quality in the testing patients with the smallest mean absolute error (MAE, 43.5 +/- 6.69), largest structural similarity (SSIM, 93.7 +/- 3.88) and peak signal-to-noise ratio (PSNR, 29.5 +/- 2.36). The sCT images generated by all the three methods showed superior dose calculation accuracy with higher gamma passing rates compared with original CBCT image. The AGGAN offered the highest gamma passing rates (91.4 +/- 3.26) under the strictest criteria of 1 mm/1% compared with other methods. In the phantom study, the sCT images generated by AGGAN demonstrated the best image quality and the highest dose calculation accuracy. Conclusions High-quality sCT images were generated from low-dose thoracic CBCT images by using the proposed AGGAN through unpaired CBCT and CT images. The dose distribution could be calculated accurately based on sCT images in radiotherapy.
引用
收藏
页数:16
相关论文
共 47 条
[11]   Effect of scattered radiation on image noise in cone beam CT [J].
Endo, M ;
Tsunoo, T ;
Nakamori, N ;
Yoshida, K .
MEDICAL PHYSICS, 2001, 28 (04) :469-474
[12]   An evaluation of techniques for dose calculation on cone beam computed tomography [J].
Giacometti, Valentina ;
King, Raymond B. ;
Agnew, Christina E. ;
Irvine, Denise M. ;
Jain, Suneil ;
Hounsell, Alan R. ;
McGarry, Conor K. .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1096)
[13]  
Goodfellow IJ, 2014, ADV NEURAL INFORM PR, V27, P2672, DOI DOI 10.1145/3422622
[14]   ScatterNet: A convolutional neural network for cone-beam CT intensity correction [J].
Hansen, David C. ;
Landry, Guillaume ;
Kamp, Florian ;
Li, Minglun ;
Belka, Claus ;
Parodi, Katia ;
Kurz, Christopher .
MEDICAL PHYSICS, 2018, 45 (11) :4916-4926
[15]  
Hao Tang, 2019, INT JOINT C NEUR N N
[16]   Paired cycle-GAN-based image correction for quantitative cone-beam computed tomography [J].
Harms, Joseph ;
Lei, Yang ;
Wang, Tonghe ;
Zhang, Rongxiao ;
Zhou, Jun ;
Tang, Xiangyang ;
Curran, Walter J. ;
Liu, Tian ;
Yang, Xiaofeng .
MEDICAL PHYSICS, 2019, 46 (09) :3998-4009
[17]  
Isola P., 2017 IEEE C COMP VIS, P5967
[18]   Radiation dose from cone beam computed tomography for image-guided radiation therapy [J].
Kan, Monica W. K. ;
Leung, Lucullus H. T. ;
Wong, Wicger ;
Lam, Nelson .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01) :272-279
[19]   Visual enhancement of Cone-beam CT by use of CycleGAN [J].
Kida, Satoshi ;
Kaji, Shizuo ;
Nawa, Kanabu ;
Imae, Toshikazu ;
Nakamoto, Takahiro ;
Ozaki, Sho ;
Ohta, Takeshi ;
Nozawa, Yuki ;
Nakagawa, Keiichi .
MEDICAL PHYSICS, 2020, 47 (03) :998-1010
[20]   Investigating deformable image registration and scatter correction for CBCT-based dose calculation in adaptive IMPT [J].
Kurz, Christopher ;
Kamp, Florian ;
Park, Yang-Kyun ;
Zoellner, Christoph ;
Rit, Simon ;
Hansen, David ;
Podesta, Mark ;
Sharp, Gregory C. ;
Li, Minglun ;
Reiner, Michael ;
Hofmaier, Jan ;
Neppl, Sebastian ;
Thieke, Christian ;
Nijhuis, Reinoud ;
Ganswindt, Ute ;
Belka, Claus ;
Winey, Brian A. ;
Parodi, Katia ;
Landry, Guillaume .
MEDICAL PHYSICS, 2016, 43 (10) :5635-5646