Tear glucose detection combining microfluidic thread based device, amperometric biosensor and microflow injection analysis

被引:63
作者
Agustini, Deonir [1 ]
Bergamini, Marcio F. [1 ]
Marcolino-Junior, Luiz Humberto [1 ]
机构
[1] Univ Fed Parana UFPR, Dept Quim, Lab Sensores Eletroquim LabSensE, BR-81531980 Curitiba, Parana, Brazil
关键词
Tear glucose; Microfluidic device; Cotton thread; Microflow injection analysis; Toluidine blue O; Glucose oxidase; TOLUIDINE BLUE; BLOOD-GLUCOSE; ELECTROCHEMICAL POLYMERIZATION; CONTACT-LENS; ELECTRODE; SENSOR; OXIDASE; FILM; INTERFERENCE; FLUID;
D O I
10.1016/j.bios.2017.06.035
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The tear glucose analysis is an important alternative for the indirect, simple and less invasive monitoring of blood glucose levels. However, the high cost and complex manufacturing process of tear glucose analyzers combined with the need to exchange the sensor after each analysis in the disposable tests prevent widespread application of the tear in glucose monitoring. Here, we present the integration of a biosensor made by the electropolymerization of poly(toluidine blue O) (PTB) and glucose oxidase (GOx) with an electroanalytical microfluidic device of easy assembly based on cotton threads, low cost materials and measurements by microflow injection analysis (mu FIA) through passive pumping for performing tear glucose analyses in a simple, rapid and inexpensive way. A high stability between the analyses (RSD = 2.54%) and among the different systems (RSD = 3.13%) was obtained for the determination of glucose, in addition to a wide linear range between 0.075 and 7.5 mmol L-1 and a limit of detection of 22.2 mu mol L-1. The proposed method was efficiently employed in the determination of tear glucose in non-diabetic volunteers, obtaining a close correlation with their blood glucose levels, simplifying and reducing the costs of the analyses, making the tear glucose monitoring more accessible for the population.
引用
收藏
页码:161 / 167
页数:7
相关论文
共 48 条
[1]   Investigating pipeline and state of the art blood glucose biosensors to formulate next steps [J].
Aggidis, Anthony G. A. ;
Newman, Jeffrey D. ;
Aggidis, George A. .
BIOSENSORS & BIOELECTRONICS, 2015, 74 :243-262
[2]   Characterization and optimization of low cost microfluidic thread based electroanalytical device for micro flow injection analysis [J].
Agustini, Deonir ;
Bergamini, Marcio F. ;
Marcolino-Junior, Luiz Humberto .
ANALYTICA CHIMICA ACTA, 2017, 951 :108-115
[3]   Low cost microfluidic device based on cotton threads for electroanalytical application [J].
Agustini, Deonir ;
Bergamini, Marcio F. ;
Marcolino-Junior, Luiz Humberto .
LAB ON A CHIP, 2016, 16 (02) :345-352
[4]   Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses [J].
Ascaso, Francisco J. ;
Huerva, Valentin .
OPTOMETRY AND VISION SCIENCE, 2016, 93 (04) :426-434
[5]   Noninvasive continuous monitoring of physiological glucose using a monosaccharide-sensing contact lens [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :610-618
[6]   Glucose oxidase - An overview [J].
Bankar, Sandip B. ;
Bule, Mahesh V. ;
Singhal, Rekha S. ;
Ananthanarayan, Laxmi .
BIOTECHNOLOGY ADVANCES, 2009, 27 (04) :489-501
[7]   Electrochemical polymerization of toluidine blue o and its electrocatalytic activity toward NADH oxidation [J].
Cai, CX ;
Xue, KH .
TALANTA, 1998, 47 (05) :1107-1119
[8]   Miniaturized flow system based on enzyme modified PMMA microreactor for amperometric determination of glucose [J].
Cerdeira Ferreira, Luis Marcos ;
da Costa, Eric Tavares ;
do Lago, Claudimir Lucio ;
Angnes, Lucio .
BIOSENSORS & BIOELECTRONICS, 2013, 47 :539-544
[9]   Origin of Low Detection Limit and High Selectivity of Roche Accu-Chek Test Strips that Enables Measurement of Tear Glucose Levels [J].
Cha, Kyoung Ha ;
Qin, Yu ;
Meyerhoff, Mark E. .
ELECTROANALYSIS, 2015, 27 (03) :670-676
[10]   Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment [J].
Chu, Ming Xing ;
Miyajima, Kumiko ;
Takahashi, Daishi ;
Arakawa, Takahiro ;
Sano, Kenji ;
Sawada, Shin-ichi ;
Kudo, Hiroyuki ;
Iwasaki, Yasuhiko ;
Akiyoshi, Kazunari ;
Mochizuki, Manabu ;
Mitsubayashi, Kohji .
TALANTA, 2011, 83 (03) :960-965