Factors Influencing Lesion Detection in SPECT Lung Images

被引:0
作者
Gifford, H. C. [1 ]
Zheng, X. M. [2 ]
Licho, R. [1 ]
Pretorius, P. H. [1 ]
Schneider, P. B. [1 ]
Simkin, P. H. [1 ]
King, M. A. [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01605 USA
[2] Charles Sturt Univ, Sch Clin Sci, Wagga Wagga, NSW, Australia
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
D O I
10.1109/NSSMIC.2006.356429
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An earlier localization ROC (LROC) study that found attenuation correction (AC) degraded the detection of solitary pulmonary nodules (SPN) in hybrid SPECT lung images had several potential shortcomings related to the simulation methods. We sought to address these issues with a revised LROC study. Clinical Tc-99m NeoTect scans acquired with a simultaneous transmission-emission protocol defined the normal cases in a single-slice LROC study. Abnormal cases contained a simulated 1-cm lung lesion. Four rescaled-block-iterative EM (RBI) reconstruction strategies applied: 1) AC, scatter correction (SC), and resolution compensation (RC); 2) AC only; 3) RC only; and 4) no corrections (NC). Images from these strategies underwent 3D Gaussian post-smoothing. Performances were defined by the average area under the LROC curve obtained from three human observers. The strategy ranking in order of decreasing performance was: 1) RBI with RC; 2) RBI with all corrections; 3) RBI with AC; and 4) RBI with no corrections. A multireader-multicase (MRMC) analysis only found significant patient and patient-strategy effects. The conflicting results concerning AC from this study and the previous one may revolve around lesion masking effects, which, by design, were not a factor in the current study.
引用
收藏
页码:2662 / 2666
页数:5
相关论文
共 50 条
[31]   Unsupervised border detection of skin lesion images [J].
Celebi, ME ;
Aslandogan, YA ;
Bergstresser, PR .
ITCC 2005: INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY: CODING AND COMPUTING, VOL 2, 2005, :123-128
[32]   FACTORS INFLUENCING THE HISTOLOGIC APPEARANCE OF THE LUNG [J].
KRAHL, VE .
ANATOMICAL RECORD, 1956, 124 (02) :321-321
[33]   FACTORS INFLUENCING CLEARANCE OF BACTERIA BY LUNG [J].
GREEN, GM ;
KASS, EH .
JOURNAL OF CLINICAL INVESTIGATION, 1964, 43 (04) :769-&
[34]   FACTORS INFLUENCING LUNG HISTAMINE CONTENT [J].
VOELKEL, NF ;
NEWMAN, JH ;
AROYAVE, CM ;
REEVES, JT .
AGENTS AND ACTIONS, 1981, 11 (03) :204-207
[35]   FACTORS INFLUENCING FUNCTION OF AUTOTRANSPLANTED LUNG [J].
BRODY, JS ;
FISHER, AB ;
PARK, CD ;
HYDE, RW ;
WALDHAUSEN, JA .
JOURNAL OF APPLIED PHYSIOLOGY, 1970, 29 (05) :587-+
[36]   Lesion detection capability of posterior 180 degree SPECT compared to full 360 degree SPECT [J].
Khan, SH ;
Holder, LE ;
Kuhn, D ;
Kelty, N .
JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) :195P-195P
[37]   FACTORS INFLUENCING GROWTH OF SMALL PHOTOGRAPHIC IMAGES [J].
GILMORE, HF .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (10) :1375-&
[38]   Incorporating SPECT Functional Lung Images in Routine Treatment Planning for Lung Cancer [J].
Shen, S. ;
Spencer, S. ;
Bender, L. ;
Duan, J. .
MEDICAL PHYSICS, 2008, 35 (06) :2876-+
[39]   The Study On Protection of Lung Function in Radiotherapy by Referring SPECT Lung Perfusion Images [J].
Chen, J. ;
Yin, Y. .
MEDICAL PHYSICS, 2009, 36 (06)
[40]   Improving Lung Lesion Detection in Low Dose Positron Emission Tomography Images Using Machine Learning [J].
Nai, Yinghwey ;
Schaefferkoetter, Joshua D. ;
Fakhry-Darian, Daniel ;
Conti, Maurizio ;
Shi, Xinmei ;
Townsend, David W. ;
Sinha, Arvind K. ;
Tham, Ivan ;
Alexander, Daniel C. ;
Reilhac, Anthonin .
2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,