Comparison of transvaginal sonographic cervical length measurement and Bishop score for predicting labour induction outcomes

被引:4
|
作者
Vince, Katja [1 ]
Poljicanin, Tamara [2 ]
Matijevic, Ratko [1 ,2 ,3 ]
机构
[1] Univ Hosp Merkur, Dept Gynecol & Obstet, Zajceva 19, Zagreb 10000, Croatia
[2] Croatian Inst Publ Hlth, Dept Biostat, Zagreb, Croatia
[3] Univ Zagreb, Sch Med, Dept Gynecol & Obstet, Zagreb, Croatia
关键词
Bishop score; labour induction; prediction; transvaginal sonography; unfavourable cervix; SUCCESS;
D O I
10.1515/jpm-2022-0140
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objectives Induction of labour (IOL) is of increasing prevalence worldwide and reliable prediction of its successful outcome is important. Traditional clinical methods for predicting successful IOL outcomes have been supplemented with newer technologies. The aim of this study was to compare transvaginal sonographic (TVS) cervical length measurement with Bishop score in predicting labour induction outcomes. Methods This study included pregnant women with term pregnancy, indication for IOL and unfavourable cervix (Bishop score >6) who had TVS performed prior to IOL. Exclusion critetia were regular contractions, ruptured membranes, non-cephalic presentation, uterine scar and pregnancy complications potentially influencing study outcomes. Outcomes measured were successful IOL defined as achievement of active phase of labour and vaginal delivery. Receiver operating characteristic (ROC) curves were used to determine diagnostic accuracy and sensitivity, specificity, positive and negative predictive values. Statistical significance was defined as pResults Among 112 studied participants, IOL was successful in 101 (90.2%) pregnant women. AUC for Bishop score >2 was 0.831 (95% CI, 0.744-0.917, p<0.001) and for cervical length <30 mm 0.679 (95% CI 0.514-0.844, p<0.052). A total of 81 (72.3%) pregnant women delivered vaginally; AUC for Bishop score >2 was 0.754 (95% CI 0.648-0.861, p<0.001) and for cervical length <30 mm 0.602 (95% CI 0.484-0.720, p=0.092) which was the only insignificant predictor. Conclusions Bishop score >2 is a better predictor for both successful IOL and vaginal delivery among induced women with term pregnancy and unfavourable cervix compared to cervical length <30 mm.
引用
收藏
页码:1198 / 1202
页数:5
相关论文
共 50 条
  • [21] Comparative study Of TVS cervical score and Bishop score in prediction of successful labour induction
    Alka Agrawal
    P. S. Tripathi
    Gaurav Bhandari
    Pramita Kheti
    Gulshan Madhpuriya
    Roshani Rathore
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [22] Preinduction sonographic measurement of cervical length in the prediction of successful induction of labor
    Pandis, GK
    Papageorghiou, AT
    Ramanathan, VG
    Thompson, MO
    Nicolaides, KH
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (06) : 623 - 628
  • [23] Transvaginal ultrasonography compared with Bishop score for predicting cesarean section after induction of labor
    Bastani, Parvin
    Hamdi, Kobra
    Abasalizadeh, Fatemeh
    Pourmousa, Parisa
    Ghatrehsamani, Fatemeh
    INTERNATIONAL JOURNAL OF WOMENS HEALTH, 2011, 3 : 277 - 280
  • [24] The Role of Sonographic Cervical Length in Labor Induction at Term
    Papillon-Smith, Jessica
    Abenhaim, Haim A.
    JOURNAL OF CLINICAL ULTRASOUND, 2015, 43 (01) : 7 - 16
  • [25] Insulin-like growth factor binding protein 1, Bishop score, and sonographic cervical length: tolerability and prediction of vaginal birth and vaginal birth within 24 hours following labour induction in nulliparous women
    Vallikkannu, N.
    Lam, W. K.
    Omar, S. Z.
    Tan, P. C.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 (08) : 1274 - 1283
  • [26] Manipal Cervical Scoring System by Transvaginal Ultrasound in Predicting Successful Labour Induction
    Bajpai, Neha
    Bhakta, Rajesh
    Kumar, Pratap
    Rai, Lavanya
    Hebbar, Shripad
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (05) : QC4 - QC9
  • [27] Cervix assessment for the management of labor induction: Reliability of cervical length and Bishop score determined by residents
    Garcia-Simon, Raquel
    Oros, Daniel
    Gracia-Colera, Daniel
    Moreno, Esther
    Paules, Cristina
    Canizares, Silvia
    Gascon, Elena
    Fabre, Ernesto
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2015, 41 (03) : 377 - 382
  • [28] Transvaginal sonographic assessment of cervical length and wedging for predicting outcome of labor induction at term: a systematic review and meta-analysis
    Verhoeven, C. J. M.
    Opmeer, B. C.
    Oei, S. G.
    Latour, V.
    van der Post, J. A. M.
    Mol, B. W. J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 42 (05) : 500 - 508
  • [29] Value of Bishop score and ultrasound cervical length measurement in the prediction of cesarean delivery
    Cubal, Adelaide
    Carvalho, Joana
    Ferreira, Maria Joao
    Rodrigues, Graca
    Do Carmo, Olimpia
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2013, 39 (09) : 1391 - 1396
  • [30] Reliability of the Bishop score before labour induction at term
    Faltin-Traub, EF
    Boulvain, M
    Faltin, DL
    Extermann, P
    Irion, O
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2004, 112 (02) : 178 - 181