Surface plasmon resonance biosensor using heterodyne interferometry

被引:0
|
作者
Joe, SF
Wu, CM
Chang, LB
Hsieh, LZ
机构
来源
ADVANCED SENSOR SYSTEMS AND APPLICATIONS II PT 1AND 2 | 2004年 / 5634卷
关键词
surface plasmon resonance; biosensor; heterodyne inteferometry;
D O I
10.1117/12.573719
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Surface plasmon resonance (SPR) biosensor constructed with common path, heterodyne inteferometric system has been developed. The sensor ship consists of a BK7 substrate coated with gold film on which the receptor of the specific biomolecular or protein has been immobilized. The light source consisting of the s and p polarizations with heterodyne frequency of 60kHz is used to measure the phase difference between these two polarizations. Because the SPR sensor probes the changes of refractive index near the gold film (i.e. about one wave-length), the more the binding of molecules on the sensing surface results in the less sensitivity of the detection. In order to overcome this shortage, we set two quarter-wave plates before and after the SPR prism to make the sensitivity of measurement to be tunable. This sensor could detect the concentration of antibody of sheep IgG as low as several nanograms per milliliter. The results indicate that this system provides high sensitivity and is capable for detecting biomolecular interactions.
引用
收藏
页码:166 / 173
页数:8
相关论文
共 50 条
  • [1] Optical heterodyne surface plasmon resonance biosensor
    Chou, C
    Kuo, WC
    Wu, HT
    OPTICAL FIBERS AND SENSORS FOR MEDICAL APPLICATIONS III, 2003, 4957 : 149 - 156
  • [2] Measurement of the concentration of a solution with surface plasmon resonance heterodyne interferometry
    Chen, KH
    Hsu, CC
    Su, DC
    OPTICAL ENGINEERING, 2003, 42 (07) : 1884 - 1887
  • [3] Measuring physical parameters with surface plasmon resonance heterodyne interferometry
    Chen, Kun-Huang
    Lin, Jiun-You
    Chen, Jing-Heng
    OPTIK, 2009, 120 (01): : 29 - 34
  • [4] Angle measurement using surface-plasmon-resonance heterodyne interferometry: a new method
    Guo, JH
    Zhu, ZM
    Deng, WM
    Shen, S
    OPTICAL ENGINEERING, 1998, 37 (11) : 2998 - 3001
  • [5] Surface plasmon resonance heterodyne interferometry from measuring physical parameters
    Su, DC
    Chen, JH
    Chen, KH
    Lin, JY
    OPTICAL METROLOGY IN PRODUCTION ENGINEERING, 2004, 5457 : 566 - 573
  • [6] Measurement of small displacement based on surface plasmon resonance heterodyne interferometry
    Lin, Jiun-You
    Chen, Kun-Huang
    Chen, Jing-Heng
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (07) : 811 - 815
  • [7] A biosensor chip design for phase-stepping interferometry of surface plasmon resonance
    Wu, S. Y.
    Ho, H. P.
    PLASMONICS IN BIOLOGY AND MEDICINE III, 2006, 6099
  • [8] High-sensitivity sensor based on surface plasmon resonance and heterodyne interferometry
    Wu, CM
    Jian, ZC
    Joe, SF
    Chang, LB
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (1-2): : 133 - 136
  • [9] Rapid detection of urinary polyomavirus BK by heterodyne-based surface plasmon resonance biosensor
    Su, Li-Chen
    Tian, Ya-Chung
    Chang, Ying-Feng
    Chou, Chien
    Lai, Chao-Sung
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (01)
  • [10] Photonic crystal biosensor using surface plasmon resonance effect
    Su, Wei
    Zheng, Gaige
    Li, Xiangyin
    LEADING EDGE OF MICRO-NANO SCIENCE AND TECHNOLOGY, 2013, 669 : 246 - +