摘要
The objective of this study was to demonstrate the feasibility of 3D proton MR spectroscopic imaging (MRSI) of the prostate using a standard spine instead of a dedicated endorectal coil at 1.5 T. Twenty-eight patients (25 with biopsy proven prostate cancers and three patients with a benign prostate hyperplasia) were examined. MRI and MRSI were conducted with commercial array surface coils at 1.5 T. Ratios of choline (Cho), creatine (Cr) and citrate (Ci) were calculated for tumour, central and peripheral zone retrospectively, based on axial T2 weighed MR images and histology reports. Prostate cancer was characterized by significantly elevated (Cho+Cr)/Ci ratio compared with non-tumourous prostate tissue. The quality of all proton MR spectra was considered to be good or acceptable in 17/28 patients (61%) and poor in 11/28 (39%) examinations. In 20/25 patients with proven malignancy (80%), MRSI was considered to be helpful for the detection of prostate cancer. In 4/25 patients with proven malignancy (16%) who underwent seed implantation, radiotherapy or hormone deprivation before MR examination spectroscopy was of poor and nondiagnostic quality. MRSI of the prostate is feasible within clinical routine using the spine array surface coil at 1.5 T. It can consequently be applied to patients even with contraindications for endorectal coils. However, spectral quality and signal-to-noise ratio is clearly inferior to 3D MRSI examinations with endorectal coils.
引用
收藏
页码:653 / 660
页数:8
相关论文
共 31 条
  • [31] Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct ( 2 H) and indirect ( 1 H) detection of deuterium labeled compounds at 7T and clinical 3T*
    Niess, Fabian
    Strasser, Bernhard
    Hingerl, Lukas
    Niess, Eva
    Motyka, Stanislav
    Hangel, Gilbert
    Krssak, Martin
    Gruber, Stephan
    Spurny-Dworak, Benjamin
    Trattnig, Siegfried
    Scherer, Thomas
    Lanzenberger, Rupert
    Bogner, Wolfgang
    NEUROIMAGE, 2023, 277