3D proton MR spectroscopic imaging of prostate cancer using a standard spine coil at 1.5 T in clinical routine: a feasibility study

被引:17
|
作者
Lichy, MP
Pintaske, J
Kottke, R
Machann, J
Anastasiadis, A
Roell, S
Hennenlotter, J
Diergarten, T
Schick, F
Stenzl, A
Claussen, CD
Schlemmer, HP
机构
[1] Univ Tubingen, Sect Expt Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[3] Univ Tubingen, Dept Urol, D-72076 Tubingen, Germany
[4] Siemens AG, Med Solut MR Applicat Dev, Spect MREA MRS, D-91050 Erlangen, Germany
关键词
MR spectroscopy; prostate; cancer;
D O I
10.1007/s00330-004-2547-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to demonstrate the feasibility of 3D proton MR spectroscopic imaging (MRSI) of the prostate using a standard spine instead of a dedicated endorectal coil at 1.5 T. Twenty-eight patients (25 with biopsy proven prostate cancers and three patients with a benign prostate hyperplasia) were examined. MRI and MRSI were conducted with commercial array surface coils at 1.5 T. Ratios of choline (Cho), creatine (Cr) and citrate (Ci) were calculated for tumour, central and peripheral zone retrospectively, based on axial T2 weighed MR images and histology reports. Prostate cancer was characterized by significantly elevated (Cho+Cr)/Ci ratio compared with non-tumourous prostate tissue. The quality of all proton MR spectra was considered to be good or acceptable in 17/28 patients (61%) and poor in 11/28 (39%) examinations. In 20/25 patients with proven malignancy (80%), MRSI was considered to be helpful for the detection of prostate cancer. In 4/25 patients with proven malignancy (16%) who underwent seed implantation, radiotherapy or hormone deprivation before MR examination spectroscopy was of poor and nondiagnostic quality. MRSI of the prostate is feasible within clinical routine using the spine array surface coil at 1.5 T. It can consequently be applied to patients even with contraindications for endorectal coils. However, spectral quality and signal-to-noise ratio is clearly inferior to 3D MRSI examinations with endorectal coils.
引用
收藏
页码:653 / 660
页数:8
相关论文
共 31 条
  • [21] TUMOR VOLUME AND METABOLISM OF PROSTATE CANCER DETERMINED BY PROTON MAGNETIC RESONANCE SPECTROSCOPIC IMAGING AT 3T WITHOUT ENDORECTAL COIL REVEAL POTENTIAL CLINICAL IMPLICATIONS IN THE CONTEXT OF RADIATION ONCOLOGY
    Crehange, Gilles
    Parfait, Sebastien
    Liegard, Melanie
    Maingon, Philippe
    Ben Salem, Douraied
    Cochet, Alexandre
    de la Vega, Mathilde Funes
    Cormier, Luc
    Bonnetain, Franck
    Mirjolet, Celine
    Brunotte, Francois
    Walker, Paul M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04): : 1087 - 1094
  • [22] 3D MR-SPECTROSCOPIC IMAGING ASSESSMENT OF METABOLIC ACTIVITY IN THE PROSTATE DURING THE PSA "BOUNCE" FOLLOWING 125IODINE BRACHYTHERAPY
    Kirilova, Anna
    Damyanovich, Andrei
    Crook, Juanita
    Jezioranski, John
    Wallace, Kris
    Pintilie, Melania
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (02): : 371 - 378
  • [23] Assessment of breast arteries and lymph nodes by 3D MR angiography enhancement imaging: feasibility and pilot clinical results
    Liu, Yang
    Hou, Jiaxin
    Zhu, Zhijun
    Liu, Bingguang
    Cao, Manrui
    Qin, Wenjian
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [24] Prostate biopsy in the supine position in a standard 1.5-T scanner under real time MR-imaging control using a MR-compatible endorectal biopsy device
    Engelhard, K
    Hollenbach, HP
    Kiefer, B
    Winkel, A
    Goeb, K
    Engehausen, D
    EUROPEAN RADIOLOGY, 2006, 16 (06) : 1237 - 1243
  • [25] Prostate biopsy in the supine position in a standard 1.5-T scanner under real time MR-imaging control using a MR-compatible endorectal biopsy device
    K. Engelhard
    H. P. Hollenbach
    B. Kiefer
    A. Winkel
    K. Goeb
    D. Engehausen
    European Radiology, 2006, 16 : 1237 - 1243
  • [26] Imaging of the entire cerebrospinal fluid volume with a multistation 3D SPACE MR sequence: feasibility study in patients with hydrocephalus
    Hodel, Jerome
    Lebret, Alain
    Petit, Eric
    Leclerc, Xavier
    Zins, Marc
    Vignaud, Alexandre
    Decq, Philippe
    Rahmouni, Alain
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1450 - 1458
  • [27] Fast 3D T2-weighted imaging using variable flip angle transition into driven equilibrium (3D T2-TIDE) balanced SSFP for prostate imaging at 3T
    Srinivasan, Subashini
    Wu, Holden H.
    Sung, Kyunghyun
    Margolis, Daniel J. A.
    Ennis, Daniel B.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 442 - 451
  • [28] 3.0 T prostate MRI: Visual assessment of 2D and 3D T2-weighted imaging sequences using PI-QUAL score
    Brillat-Savarin, Nina
    Wu, Carine
    Aupin, Laurene
    Thoumin, Camille
    Hamzaoui, Dimitri
    Renard-Penna, Raphaele
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166
  • [29] Topographical mapping of metabolic abnormalities in multiple sclerosis using rapid echo-less 3D-MR spectroscopic imaging at 7T
    Niess, Eva
    Dal-Bianco, Assunta
    Strasser, Bernhard
    Niess, Fabian
    Hingerl, Lukas
    Bachrata, Beata
    Motyka, Stanislav
    Rommer, Paulus
    Trattnig, Siegfried
    Bogner, Wolfgang
    NEUROIMAGE, 2025, 308
  • [30] Evaluating the accuracy of multicomponent T2 parameters for luminal water imaging of the prostate with acceleration using inner-volume 3D GRASE
    Chan, Rachel W.
    Lau, Angus Z.
    Detzler, Garry
    Thayalasuthan, Vivekanandan
    Nam, Robert K.
    Haider, Masoom A.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 466 - 476