Heart rate measurement based on a time-lapse image

被引:259
作者
Takano, Chihiro [1 ]
Ohta, Yuji [1 ]
机构
[1] Ochanomizu Univ, Grad Sch Human & Sci, Tokyo 112, Japan
关键词
respiratory rate; heart rate; time-lapse image; non-contact measurement;
D O I
10.1016/j.medengphy.2006.09.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Using a time-lapse image acquired from a CCD camera, we developed a non-contact and non-invasive device, which could measure both the respiratory and pulse rate simultaneously. The time-lapse image of a part of the subject's skin was consecutively captured, and the changes in the average image brightness of the region of interest (ROI) were measured for 30 s. The brightness data were processed by a series of operations of interpolation as follows a first-order derivative, a low pass filter of 2 Hz, and a sixth-order auto-regressive (AR) spectral analysis. Fourteen sound and healthy female subjects (22-27 years of age) participated in the experiments. Each subject was told to keep a relaxed seating posture with no physical restriction. At the same time, heart rate was measured by a pulse oximeter and respiratory rate was measured by a thermistor placed at the external naris. Using AR spectral analysis, two clear peaks could be detected at approximately 0.3 and 1.2 Hz. The peaks were thought to correspond to the respiratory rate and the heart rate. Correlation coefficients of 0.90 and 0.93 were obtained for the measurement of heart rate and respiratory rate, respectively. (c) 2006 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:853 / 857
页数:5
相关论文
共 35 条
[1]   Noninvasive investigation of blood pressure changes using the pulse wave transit time: A novel approach in the monitoring of hemodialysis patients [J].
Ahlstrom C. ;
Johansson A. ;
Uhlin F. ;
Länne T. ;
Ask P. .
Journal of Artificial Organs, 2005, 8 (3) :192-197
[2]   Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites [J].
Allen, J ;
Murray, A .
PHYSIOLOGICAL MEASUREMENT, 2003, 24 (02) :297-307
[3]   Improved fibre optic respiratory monitoring using a figure-of-eight coil [J].
Augousti, AT ;
Maletras, FX ;
Mason, J .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (05) :585-590
[4]   Chest wall and lung volume estimation by optical reflectance motion analysis [J].
Cala, SJ ;
Kenyon, CM ;
Ferrigno, G ;
Carnevali, P ;
Aliverti, A ;
Pedotti, A ;
Macklem, PT ;
Rochester, DF .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (06) :2680-2689
[5]   Assessment of activity of elderly people using a home monitoring system [J].
Chan, M ;
Campo, E ;
Estève, D .
INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2005, 28 (01) :69-76
[6]  
Chan Marie, 2002, Technol Health Care, V10, P391
[7]   Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier [J].
Chen, KM ;
Huang, Y ;
Zhang, JP ;
Norman, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (01) :105-114
[8]   Unconstrained detection of respiration rhythm and pulse rate with one under-pillow sensor during sleep [J].
Chen, W ;
Zhu, X ;
Nemoto, T ;
Kanemitsu, Y ;
Kitamura, K ;
Yamakoshi, K .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (02) :306-312
[9]   Automatic recognition of eye blinking in spontaneously occurring behavior [J].
Cohn, JF ;
Xiao, J ;
Moriyama, T ;
Ambadar, Z ;
Kanade, T .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 2003, 35 (03) :420-428
[10]  
Collins CY, 2005, J REPROD MED, V50, P379