Steady-state performance evaluation and energy assessment of a complete membrane-based liquid desiccant dehumidification system

被引:22
|
作者
Bai, Hongyu [1 ]
Zhu, Jie [1 ]
Chen, Xiangjie [1 ]
Chu, Junze [1 ]
Cui, Yuanlong [2 ]
Yan, Yuying [1 ]
机构
[1] Univ Nottingham, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
[2] Univ Derby, Dept Mech Engn & Built Environm, Derby DE22 3AW, England
关键词
Complete dehumidification system; Liquid desiccant; Numerical modelling; Cooling capacity; COP; AIR DEHUMIDIFICATION; MASS-TRANSFER; HEAT; FLOW; COMFORT; DESIGN; MODEL;
D O I
10.1016/j.apenergy.2019.114082
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A complete membrane-based liquid desiccant dehumidification system is investigated under the steady operating condition, which mainly consists of a dehumidifier, a regenerator, three heat exchangers, a cold and a hot water supply units. A finite difference mathematical model is developed for the complete system to investigate the system dehumidification performance and energy requirement, and validated by experimental data. The dehumidification performance is evaluated by the system sensible and latent effectiveness and moisture flux rate, while its energy performance is assessed by the total cooling capacity and coefficient of performance. It is found that the number of heat transfer units in the dehumidifier side and solution to air mass flow rate ratio have the most considerable impact on the system performance, while the number of heat transfer units in the regenerator side and solution inlet concentration in the dehumidifier have comparatively weak influences. The system sensible and latent effectiveness can be improved by increasing the dehumidifier side number of heat transfer units before reaching its critical value of 6. However, the amount of moisture being absorbed, total cooling capacity and coefficient of performance decrease with the dehumidifier side number of heat transfer units at the low air flow rate. The critical value of solution to air mass flow rate ratio varies with number of heat transfer units, and it is preferable to keep the flow rate ratio at or below its critical value as further increasing solution flow rate would reduce the system coefficient of performance.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant
    Liu, Xiaoli
    Qu, Ming
    Liu, Xiaobing
    Wang, Lingshi
    Warner, Joseph
    Gao, Zhiming
    APPLIED THERMAL ENGINEERING, 2020, 181
  • [32] Performance assessment of PCM-based solar energy assisted desiccant air conditioning system combined with a humidification-dehumidification desalination unit
    Wang, Nan
    Wang, Dongxuan
    Dong, Jungang
    Wang, Haitao
    Wang, Renliang
    Shao, Limin
    Zhu, Yiping
    DESALINATION, 2020, 496
  • [33] Assessment of dehumidification performance of non-corrosive desiccant in hybrid liquid desiccant-vapour compression system
    Kumar, Kashish
    Singh, Alok
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (03) : 6909 - 6926
  • [34] Performance analysis of a novel frost-free air-source heat pump with integrated membrane-based liquid desiccant dehumidification and humidification
    Su, Wei
    Zhang, Xiaosong
    ENERGY AND BUILDINGS, 2017, 145 : 293 - 303
  • [35] Performance optimization of polymeric porous membrane-based liquid desiccant air dehumidifier used in air conditioning system
    Ali Mohammad Jafarpour
    Farivar Fazelpour
    Seyyed Abbas Mousavi
    International Journal of Energy and Environmental Engineering, 2020, 11 : 55 - 71
  • [36] Study on the optimal solution recirculation ratio of liquid desiccant dehumidification system based on matching rate evaluation
    Zhang, Guangkai
    Xie, Jingchao
    Ji, Ying
    Du, Boyao
    Liu, Honggang
    Liu, Jiaping
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [37] Experimentation of a Membrane-based Concentration Gradient Energy Storage of Liquid Desiccant Solutions Driven by Solar Energy
    Wang, Zanshe
    Li, Ran
    Yin, Fangting
    Wu, Yue
    Gu, Zhaolin
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (05) : 1503 - 1512
  • [38] State-of-art in modelling methods of membrane-based liquid desiccant heat and mass exchanger: A comprehensive review
    Bai, Hongyu
    Zhu, Jie
    Chen, Ziwei
    Chu, Junze
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 125 : 445 - 470
  • [39] Performance characteristics of a novel internally-cooled plate membrane liquid desiccant air dehumidification system
    Xiao, Liehui
    Yang, Minlin
    Yuan, Wu-Zhi
    Huang, Si-Min
    APPLIED THERMAL ENGINEERING, 2020, 172
  • [40] Performance evaluation of an innovative liquid desiccant air-conditioning system directly integrating a heat pump with two membrane energy exchangers
    Elsheniti, Mahmoud Badawy
    Shehata, Ahmed
    Attia, Abd El-Hamid
    El-Maghlany, Wael
    ENERGY CONVERSION AND MANAGEMENT, 2023, 293