Steady-state performance evaluation and energy assessment of a complete membrane-based liquid desiccant dehumidification system

被引:22
|
作者
Bai, Hongyu [1 ]
Zhu, Jie [1 ]
Chen, Xiangjie [1 ]
Chu, Junze [1 ]
Cui, Yuanlong [2 ]
Yan, Yuying [1 ]
机构
[1] Univ Nottingham, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
[2] Univ Derby, Dept Mech Engn & Built Environm, Derby DE22 3AW, England
关键词
Complete dehumidification system; Liquid desiccant; Numerical modelling; Cooling capacity; COP; AIR DEHUMIDIFICATION; MASS-TRANSFER; HEAT; FLOW; COMFORT; DESIGN; MODEL;
D O I
10.1016/j.apenergy.2019.114082
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A complete membrane-based liquid desiccant dehumidification system is investigated under the steady operating condition, which mainly consists of a dehumidifier, a regenerator, three heat exchangers, a cold and a hot water supply units. A finite difference mathematical model is developed for the complete system to investigate the system dehumidification performance and energy requirement, and validated by experimental data. The dehumidification performance is evaluated by the system sensible and latent effectiveness and moisture flux rate, while its energy performance is assessed by the total cooling capacity and coefficient of performance. It is found that the number of heat transfer units in the dehumidifier side and solution to air mass flow rate ratio have the most considerable impact on the system performance, while the number of heat transfer units in the regenerator side and solution inlet concentration in the dehumidifier have comparatively weak influences. The system sensible and latent effectiveness can be improved by increasing the dehumidifier side number of heat transfer units before reaching its critical value of 6. However, the amount of moisture being absorbed, total cooling capacity and coefficient of performance decrease with the dehumidifier side number of heat transfer units at the low air flow rate. The critical value of solution to air mass flow rate ratio varies with number of heat transfer units, and it is preferable to keep the flow rate ratio at or below its critical value as further increasing solution flow rate would reduce the system coefficient of performance.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system
    Bai, Hongyu
    Zhu, Jie
    Chen, Ziwei
    Ma, Lina
    Wang, Ruzhu
    Li, Tingxian
    APPLIED THERMAL ENGINEERING, 2017, 119 : 119 - 131
  • [2] The design and experimental investigation of membrane-based tubular liquid desiccant dehumidification system
    Kavasogullari, Baris
    Cihan, Ertugrul
    Demir, Hasan
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2023, 29 (04): : 303 - 313
  • [3] Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations
    Chen, Ziwei
    Zhu, Jie
    Bai, Hongyu
    ENERGY AND BUILDINGS, 2017, 139 : 665 - 679
  • [4] Researches and trends in membrane-based liquid desiccant air dehumidification
    Huang, Si-Min
    Zhang, Li-Zhi
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 28 : 425 - 440
  • [5] Performance Investigation of a Hollow Fiber Membrane-Based Desiccant Liquid Air Dehumidification System
    Englart, Sebastian
    Rajski, Krzysztof
    ENERGIES, 2021, 14 (11)
  • [6] Membrane-based packed-sheet liquid desiccant dehumidification system
    Elsafi, Amin M.
    Bahrami, Majid
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [7] A heat pump driven and hollow fiber membrane-based liquid desiccant air dehumidification system: A transient performance study
    Zhang, Ning
    Zhang, Li-Zhi
    Xu, Jian-Chang
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 143 - 156
  • [8] Performance evaluation of a membrane-based flat-plate heat and mass exchanger used for liquid desiccant regeneration
    Bai, Hongyu
    Zhu, Jie
    Chen, Ziwei
    Chu, Junze
    Liu, Yiwen
    APPLIED THERMAL ENGINEERING, 2018, 139 : 569 - 584
  • [9] Performance characterization of a novel membrane-based liquid desiccant air conditioning system
    Gurubalan, A.
    Maiya, M. P.
    Tiwari, Shaligram
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 120 : 445 - 459
  • [10] Performance study of a heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system
    Zhang, Ning
    Yin, Shao-You
    Zhang, Li-Zhi
    APPLIED ENERGY, 2016, 179 : 727 - 737