Steady-state performance evaluation and energy assessment of a complete membrane-based liquid desiccant dehumidification system

被引:23
作者
Bai, Hongyu [1 ]
Zhu, Jie [1 ]
Chen, Xiangjie [1 ]
Chu, Junze [1 ]
Cui, Yuanlong [2 ]
Yan, Yuying [1 ]
机构
[1] Univ Nottingham, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
[2] Univ Derby, Dept Mech Engn & Built Environm, Derby DE22 3AW, England
关键词
Complete dehumidification system; Liquid desiccant; Numerical modelling; Cooling capacity; COP; AIR DEHUMIDIFICATION; MASS-TRANSFER; HEAT; FLOW; COMFORT; DESIGN; MODEL;
D O I
10.1016/j.apenergy.2019.114082
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A complete membrane-based liquid desiccant dehumidification system is investigated under the steady operating condition, which mainly consists of a dehumidifier, a regenerator, three heat exchangers, a cold and a hot water supply units. A finite difference mathematical model is developed for the complete system to investigate the system dehumidification performance and energy requirement, and validated by experimental data. The dehumidification performance is evaluated by the system sensible and latent effectiveness and moisture flux rate, while its energy performance is assessed by the total cooling capacity and coefficient of performance. It is found that the number of heat transfer units in the dehumidifier side and solution to air mass flow rate ratio have the most considerable impact on the system performance, while the number of heat transfer units in the regenerator side and solution inlet concentration in the dehumidifier have comparatively weak influences. The system sensible and latent effectiveness can be improved by increasing the dehumidifier side number of heat transfer units before reaching its critical value of 6. However, the amount of moisture being absorbed, total cooling capacity and coefficient of performance decrease with the dehumidifier side number of heat transfer units at the low air flow rate. The critical value of solution to air mass flow rate ratio varies with number of heat transfer units, and it is preferable to keep the flow rate ratio at or below its critical value as further increasing solution flow rate would reduce the system coefficient of performance.
引用
收藏
页数:17
相关论文
共 32 条
[1]   A review on applications of ANN and SVM for building electrical energy consumption forecasting [J].
Ahmad, A. S. ;
Hassan, M. Y. ;
Abdullah, M. P. ;
Rahman, H. A. ;
Hussin, F. ;
Abdullah, H. ;
Saidur, R. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 33 :102-109
[2]   Parametric study of the proton exchange membrane fuel cell for investigation of enhanced performance used in fuel cell vehicles [J].
Babu, Attuluri R. Vijay ;
Kumar, P. Manoj ;
Rao, G. Srinivasa .
ALEXANDRIA ENGINEERING JOURNAL, 2018, 57 (04) :3953-3958
[3]   Effect of Design and Operating Parameters on the Performance of Planar and Ducted Cathode Structures of an Air-Breathing PEM Fuel Cell [J].
Babu, Attuluri R. Vijay ;
Kumar, Pantalingal Manoj ;
Rao, Gorantla Srinivasa .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2016, 41 (09) :3415-3423
[4]   Performance evaluation of a membrane-based flat-plate heat and mass exchanger used for liquid desiccant regeneration [J].
Bai, Hongyu ;
Zhu, Jie ;
Chen, Ziwei ;
Chu, Junze ;
Liu, Yiwen .
APPLIED THERMAL ENGINEERING, 2018, 139 :569-584
[5]   Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: Numerical and experimental data [J].
Bai, Hongyu ;
Zhu, Jie ;
Chen, Ziwei ;
Chu, Junze .
ENERGY AND BUILDINGS, 2018, 158 :494-508
[6]   Performance testing of a cross-flow membrane-based liquid desiccant dehumidification system [J].
Bai, Hongyu ;
Zhu, Jie ;
Chen, Ziwei ;
Ma, Lina ;
Wang, Ruzhu ;
Li, Tingxian .
APPLIED THERMAL ENGINEERING, 2017, 119 :119-131
[7]  
Becerik-Gerber B, 2013, J COMPUT CIVIL ENG
[8]  
Frank DPD, 2012, PRINCIPLEHEAT MASS
[9]   Analytical model based performance evaluation, sizing and coupling flow optimization of liquid desiccant run-around membrane energy exchanger systems [J].
Ge, Gaoming ;
Moghaddam, Davood Ghadiri ;
Namvar, Ramin ;
Simonson, Carey J. ;
Besant, Robert W. .
ENERGY AND BUILDINGS, 2013, 62 :248-257
[10]   Steady-state performance of a run-around membrane energy exchanger (RAMEE) for a range of outdoor air conditions [J].
Hemingson, Howard B. ;
Simonson, Carey J. ;
Besant, Robert W. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (9-10) :1814-1824