Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine

被引:13
作者
Nassenstein, Kai [1 ]
Eberle, Holger [2 ]
Maderwald, Stefan [1 ,3 ]
Jensen, Christoph J. [2 ]
Heilmaier, Christina [1 ]
Schlosser, Thomas [1 ]
Bruder, Oliver [2 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[2] Elisabeth Hosp, Dept Cardiol & Angiol, Essen, Germany
[3] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
关键词
Cine magnetic resonace imaging; Parallel imaging; TGRAPPA; Cardiac volume; Left ventricular function; MODELING ANALYSIS; ACQUISITION; REPRODUCIBILITY; QUALITY; HEART; SENSE;
D O I
10.1007/s00330-010-1827-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate a TGRAPPA (temporal parallel acquisition technique)-accelerated, single breath-hold multi-slice cine imaging approach for the assessment of left ventricular (LV) function. One hundred eleven patients were examined at 1.5 T. Cine imaging was performed with single-slice breath-hold acquisitions in short-axis orientation using a SSFP (TR 2.63 ms, TE 1.12 ms, FA 72A degrees) sequence and a TGRAPPA SSFP (TR 2.66 ms, TE 1.11 ms, FA 72A degrees, AF 3) sequence, which covered the entire LV in multiple short-axis slices during a single breath-hold. End-diastolic (EDV), end-systolic (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM) and regional wall motion were assessed for both data sets. Single breath-hold imaging was feasible in 108 patients. Excellent correlations were observed for all volumetric parameters derived from both data sets (all r > 0.97). While EDV and ESV showed marginally lower values for single breath-hold imaging (EDV: -1.6 +/- 7.9 ml; ESV: -1.8 +/- 6.0 ml, p < 0.05), no differences were observed for SV, EF, MM and regional wall motion assessment. Single breath-hold imaging required significant shorter acquisition times (28 +/- 6 s vs. 335 +/- 87 s). TGRAPPA-accelerated multi-slice SSPF imaging allows for fast and accurate assessment of regional and global LV function within a single breath-hold.
引用
收藏
页码:2341 / 2347
页数:7
相关论文
共 50 条
  • [41] Age- and gender-specific differences in left and right ventricular cardiac function and mass determined by cine magnetic resonance imaging
    Sandstede, J
    Lipke, C
    Beer, M
    Hofmann, S
    Pabst, T
    Kenn, W
    Neubauer, S
    Hahn, D
    EUROPEAN RADIOLOGY, 2000, 10 (03) : 438 - 442
  • [42] Assessment of Left Ventricular Function and Mass on Free-Breathing Compressed Sensing Real-Time Cine Imaging
    Kido, Tomoyuki
    Kido, Teruhito
    Nakamura, Masashi
    Watanabe, Kouki
    Schmidt, Michaela
    Forman, Christoph
    Mochizuki, Teruhito
    CIRCULATION JOURNAL, 2017, 81 (10) : 1463 - 1468
  • [43] Noninvasive evaluation of global and regional left ventricular function using computed tomography and magnetic resonance imaging: a meta-analysis
    Kaniewska, Malwina
    Schuetz, Georg M.
    Willun, Steffen
    Schlattmann, Peter
    Dewey, Marc
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1640 - 1659
  • [44] Pancreatic adenocarcinoma: a pilot study of quantitative perfusion and diffusion-weighted breath-hold magnetic resonance imaging
    Kim, Hyunki
    Arnoletti, Pablo J.
    Christein, John
    Heslin, Martin J.
    Posey, James A., III
    Pednekar, Amol
    Beasley, T. Mark
    Morgan, Desiree E.
    ABDOMINAL IMAGING, 2014, 39 (04): : 744 - 752
  • [45] MEASUREMENT OF REGIONAL LEFT-VENTRICULAR FUNCTION USING LABELED MAGNETIC-RESONANCE-IMAGING
    BUCHALTER, MB
    SIMS, C
    DIXON, AK
    WEISSBERG, PL
    STONE, DL
    SHAH, NJ
    HALL, LD
    WILKINSON, ID
    LOMAS, DJ
    FREER, CEL
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (766) : 953 - 958
  • [46] Global and regional left ventricular function assessment with 16-detector row CT: Comparison with echocardiography and cardiovascular magnetic resonance
    Salm, Liesbeth P.
    Schuijf, Joanne D.
    de Roos, Albert
    Lamb, Hildo J.
    Vliegen, Hubert W.
    Jukema, J. Wouter
    Joemai, Raoul
    van der Wall, Ernst E.
    Bax, Jeroen J.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2006, 7 (04): : 308 - 314
  • [47] Myocardial perfusion imaging with real-time respiratory triggering: Impact of inspiration breath-hold on left ventricular functional parameters
    Buechel, Ronny R.
    Husmann, Lars
    Pazhenkottil, Aju P.
    Nkoulou, Rene
    Herzog, Bernhard A.
    Burger, Irene A.
    Ghadri, Jelena R.
    Wolfrum, Mathias
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (05) : 848 - 852
  • [48] Myocardial perfusion imaging with real-time respiratory triggering: Impact of inspiration breath-hold on left ventricular functional parameters
    Ronny R. Buechel
    Lars Husmann
    Aju P. Pazhenkottil
    Rene Nkoulou
    Bernhard A. Herzog
    Irene A. Burger
    Jelena R. Ghadri
    Mathias Wolfrum
    Philipp A. Kaufmann
    Journal of Nuclear Cardiology, 2010, 17 : 848 - 852
  • [49] Single Breath-Hold Assessment of Ventricular Volumes Using 32-Channel Coil Technology and an Extracellular Contrast Agent
    Parish, Victoria
    Hussain, Tarique
    Beerbaum, Philip
    Greil, Gerald
    Nagel, Eike
    Razavi, Reza
    Schaeffter, Tobias
    Uribe, Sergio
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) : 838 - 844
  • [50] Gated SPECT in assessment of regional and global left ventricular function: An update
    Abidov, Aiden
    Germano, Guido
    Hachamovitch, Rory
    Slomka, Piotr
    Berman, Daniel S.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (06) : 1118 - 1143