Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine

被引:13
作者
Nassenstein, Kai [1 ]
Eberle, Holger [2 ]
Maderwald, Stefan [1 ,3 ]
Jensen, Christoph J. [2 ]
Heilmaier, Christina [1 ]
Schlosser, Thomas [1 ]
Bruder, Oliver [2 ]
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[2] Elisabeth Hosp, Dept Cardiol & Angiol, Essen, Germany
[3] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, Germany
关键词
Cine magnetic resonace imaging; Parallel imaging; TGRAPPA; Cardiac volume; Left ventricular function; MODELING ANALYSIS; ACQUISITION; REPRODUCIBILITY; QUALITY; HEART; SENSE;
D O I
10.1007/s00330-010-1827-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate a TGRAPPA (temporal parallel acquisition technique)-accelerated, single breath-hold multi-slice cine imaging approach for the assessment of left ventricular (LV) function. One hundred eleven patients were examined at 1.5 T. Cine imaging was performed with single-slice breath-hold acquisitions in short-axis orientation using a SSFP (TR 2.63 ms, TE 1.12 ms, FA 72A degrees) sequence and a TGRAPPA SSFP (TR 2.66 ms, TE 1.11 ms, FA 72A degrees, AF 3) sequence, which covered the entire LV in multiple short-axis slices during a single breath-hold. End-diastolic (EDV), end-systolic (ESV), stroke volumes (SV), ejection fraction (EF), muscle mass (MM) and regional wall motion were assessed for both data sets. Single breath-hold imaging was feasible in 108 patients. Excellent correlations were observed for all volumetric parameters derived from both data sets (all r > 0.97). While EDV and ESV showed marginally lower values for single breath-hold imaging (EDV: -1.6 +/- 7.9 ml; ESV: -1.8 +/- 6.0 ml, p < 0.05), no differences were observed for SV, EF, MM and regional wall motion assessment. Single breath-hold imaging required significant shorter acquisition times (28 +/- 6 s vs. 335 +/- 87 s). TGRAPPA-accelerated multi-slice SSPF imaging allows for fast and accurate assessment of regional and global LV function within a single breath-hold.
引用
收藏
页码:2341 / 2347
页数:7
相关论文
共 24 条
[1]   Assessment of ventricular function with single breath-hold real-time steady-state free precession cine MR Imaging [J].
Barkhausen, J ;
Goyen, M ;
Rühm, SG ;
Eggebrecht, H ;
Debatin, JF ;
Ladd, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) :731-735
[2]   Comparison of techniques for the measurement of left ventricular function following cardiac transplantation [J].
Bellenger, NG ;
Marcus, NJ ;
Rajappan, K ;
Yacoub, M ;
Banner, NR ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2002, 4 (02) :255-263
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Multi-slice dynamic imaging: Complete functional cardiac MR examination within 15 seconds [J].
Bornstedt, A ;
Nagel, E ;
Schalla, S ;
Schnackenburg, B ;
Klein, C ;
Fleck, E .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :300-305
[5]   Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA) [J].
Breuer, FA ;
Kellman, P ;
Griswold, MA ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) :981-985
[6]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[7]   Correction of misaligned slices in multi-slice cardiovascular magnetic resonance using slice-to-volume registration [J].
Chandler, Adam G. ;
Pinder, Richard J. ;
Netsch, Thomas ;
Schnabel, Julia A. ;
Hawkes, David J. ;
Hill, Derek L. G. ;
Razavi, Reza .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
[8]   NORMAL HEART - EVALUATION WITH ECHO-PLANAR MR-IMAGING [J].
DAVIS, CP ;
MCKINNON, GC ;
DEBATIN, JF ;
WETTER, D ;
EICHENBERGER, AC ;
DUEWELL, S ;
VONSCHULTHESS, GK .
RADIOLOGY, 1994, 191 (03) :691-696
[9]   Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function [J].
Eberle, Holger C. ;
Nassenstein, Kai ;
Jensen, Christoph J. ;
Schlosser, Thomas ;
Sabin, Georg V. ;
Naber, Christoph K. ;
Bruder, Oliver .
EUROPEAN RADIOLOGY, 2010, 20 (01) :73-80
[10]   Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling [J].
Heilmaier, Christina ;
Nassenstein, Kai ;
Nielles-Vallespin, Sonia ;
Zuehlsdorff, Sven ;
Hunold, Peter ;
Barkhausen, Joerg .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) :492-499