A non-contact method for rod straightness measurement based on quadrant laser sensor

被引:0
|
作者
Rana, N. K. [1 ]
Sawant, R. R. [1 ]
Moon, A. H. [2 ]
机构
[1] Indian Inst Technol, Bombay, Maharashtra, India
[2] DOACC Ctr, Srinagar, Jammu & Kashmir, India
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper aims on the development of a non-contact method for measurement of straightness of the rods. The straightness of rod is a major concern in many industrial applications, especially, where rods are forcefully inserted in pipes by machines. If the rod is bent it may cause damage to the channel and the rod, which results in additional cost due to damage. This technique is based on transmitting the laser light from a laser source and the same is detected on the other end using quadrant laser sensor. If the rod is straight the transmitted beam travels along the surface of the rod and is detected by the receiving unit. If the rod is bent the transmitted beam may not reach the receiver or the receiver detects a change pattern of light. The change in detected light is calculated in terms of bend. Laser diode (wavelength 670nm) is used as source and photo diode as receiver. The signal, thus received is processed and acquired by a data acquisition cum analog to digital converter card PCL-207. The acquired signal is computed and displayed in graphical form on monitor. This method is very accurate and non-contact in nature as no direct apparatus or implantable sensor is used for measuring the bend.
引用
收藏
页码:2645 / +
页数:2
相关论文
共 50 条
  • [21] Method for Non-Contact Measurement of Mechanical Oscillations Parameters by Means of Image Sensor
    Budilov, V. N.
    Volovach, V. I.
    Shakurskiy, M. V.
    2015 INTERNATIONAL SIBERIAN CONFERENCE ON CONTROL AND COMMUNICATIONS (SIBCON), 2015,
  • [22] Non-contact Laser-based Human Respiration Rate Measurement
    Scalise, L.
    Marchionni, P.
    Ercoli, I.
    ADVANCES IN LASEROLOGY - SELECTED PAPERS OF LASER FLORENCE 2010: THE 50TH BIRTHDAY OF LASER MEDICINE WORLD, 2011, 1364 : 149 - 155
  • [23] Non-contact Measurement of the Heart Rate by a Image Sensor
    Bernacchia, Natascia
    Marchionni, Paolo
    Ercoli, Ilaria
    Scalise, Lorenzo
    SENSORS, 2015, 319 : 371 - 375
  • [24] Non-contact measurement of eyeblink by using Doppler sensor
    Maleki, Amir
    Uchida, Masafumi
    ARTIFICIAL LIFE AND ROBOTICS, 2018, 23 (02) : 279 - 285
  • [25] Signal retrieve method in wide spectrum laser non-contact vibration measurement
    Wang, Chao
    Tang, Huang
    Xiao, Qian
    Jia, Bo
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2009, 30 (12): : 2676 - 2679
  • [26] Non-contact multiband method for emissivity measurement
    Mazikowski, A
    Chrzanowski, K
    INFRARED PHYSICS & TECHNOLOGY, 2003, 44 (02) : 91 - 99
  • [27] Non-contact fruit firmness measurement by the laser air-puff method
    McGlone, VA
    Ko, SMW
    Jordan, RB
    TRANSACTIONS OF THE ASAE, 1999, 42 (05): : 1391 - 1397
  • [28] Clinical evaluation of non-contact intraocular pressure measurement method by laser interferometry
    Blanchard, S
    Dubois, P
    Zemmoury, J
    Rouland, JF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [29] Water Velocity Measurement using Contact and Non-contact Type Sensor
    Waghmare, Amit
    Naik, A. A.
    2015 COMMUNICATION, CONTROL AND INTELLIGENT SYSTEMS (CCIS), 2015, : 334 - 338
  • [30] Application of optical fiber sensor based on fluorescence in non-contact temperature measurement
    Zhang, Youjun
    Guo, Junwei
    Li, Deying
    Yibiao Jishu Yu Chuanganqi/Instrument Technique and Sensor, 1999, (10): : 36 - 37