An In Vitro Analysis on Polyurethane Foam Blocks of the Insertion Torque (IT) Values, Removal Torque Values (RTVs), and Resonance Frequency Analysis (RFA) Values in Tapered and Cylindrical Implants

被引:10
作者
Comuzzi, Luca [1 ]
Tumedei, Margherita [2 ]
D'Arcangelo, Camillo [2 ]
Piattelli, Adriano [2 ,3 ,4 ,5 ]
Iezzi, Giovanna [2 ]
机构
[1] Via Raffaello 36-A, I-31020 San Vendemiano, TV, Italy
[2] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, Via Vestini 31, I-66100 Chieti, Italy
[3] Catholic Univ San Antonio Murcia UCAM, Biomat Engn, Av Jeronimos 135, Murcia 30107, Spain
[4] Fdn Villaserena Ric, Via Leonardo Petruzzi 42, I-65013 Citta S Angelo, PE, Italy
[5] Casa Cura Villa Serena Dott L Petruzzi, Via Leonardo Petruzzi 42, I-65013 Citta S Angelo, PE, Italy
关键词
primary stability; dental implant; endosseous implants; polyurethane study; artificial bone; PRIMARY STABILITY; DENTAL IMPLANTS; SITE PREPARATION; PLACEMENT; GEOMETRY; PROTOCOL; MODELS;
D O I
10.3390/ijerph18179238
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: Several different dental implant microgeometries have been investigated in the literature for use in low-density bone sites. The polyurethane solid rigid blocks represent an optimal in vitro study model for dental implants, because their composition is characterized by symmetrical linear chains of monomers of hexa-methylene sequences producing a self-polymerization process. The aim of the present investigation was to evaluate the primary stability of cylindrical and tapered implants positioned into low-density polyurethane solid rigid blocks. Materials and Methods: Two different macrogeometries, cylindrical (4 mm diameter and 10 mm length) and tapered dental implants (4.20 mm diameter and 10 mm length), were investigated in the present study. The implants were inserted into 10 PCF and 20 PCF polyurethane blocks, with and without an additional cortical layer. The insertion torque (IT) values, the removal torque values (RTVs), and the resonance frequency analysis (RFA) values were measured and recorded. Results: A total of 80 sites were tested, and a significant increased primary stability (PS) was detected in favour of tapered dental implants when compared to cylindrical implants in all experimental conditions (p < 0.05). Higher IT, RT, and RFA values were measured in tapered implants in 10 and 20 PCF polyurethane blocks, both with and without the additional cortical layer. Conclusions: Both implants showed sufficient primary stability in poor density substrates, while, on the other hand, the tapered microgeometry showed characteristics that could also lead to clinical application in low-density posterior maxillary sites, even with a drastically decreased bone cortical component.
引用
收藏
页数:10
相关论文
共 43 条
[1]   The effect of thread pattern upon implant osseointegration [J].
Abuhussein, Heba ;
Pagni, Giorgio ;
Rebaudi, Alberto ;
Wang, Hom-Lay .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) :129-136
[2]   Histological and Histomorphometrical Evaluation of a New Implant Macrogeometry. A Sheep Study [J].
Alexandre Gehrke, Sergio ;
Tumedei, Margherita ;
Aramburu Junior, Jaime ;
Eirles Treichel, Tiago Luis ;
Kolerman, Roni ;
Lepore, Stefania ;
Piattelli, Adriano ;
Iezzi, Giovanna .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (10)
[3]   Histological and Histomorphometric Analyses of Two Bovine Bone Blocks Implanted in Rabbit Calvaria [J].
Alexandre Gehrke, Sergio ;
Mazon, Patricia ;
Del Fabbro, Massimo ;
Tumedei, Margherita ;
Arambuth Junior, Jaime ;
Perez-Diaz, Leticia ;
De Aza, Piedad N. .
SYMMETRY-BASEL, 2019, 11 (05)
[4]  
Fuster-Torres MA, 2011, INT J ORAL MAX IMPL, V26, P1051
[5]   Implant Site Under-Preparation to Compensate the Remodeling of an Autologous Bone Block Graft [J].
Anitua, Eduardo ;
Murias-Freijo, Alia ;
Alkhraisat, Mohammad Hamdan .
JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (05) :E374-E377
[6]  
[Anonymous], 1839, F183901 ASTM
[7]   Can Bone Compaction Improve Primary Implant Stability? An In Vitro Comparative Study with Osseodensification Technique [J].
Antonelli, Alessandro ;
Bennardo, Francesco ;
Brancaccio, Ylenia ;
Barone, Selene ;
Femiano, Felice ;
Nucci, Ludovica ;
Minervini, Giuseppe ;
Fortunato, Leonzio ;
Attanasio, Ferdinando ;
Giudice, Amerigo .
APPLIED SCIENCES-BASEL, 2020, 10 (23) :1-13
[8]   Sinus augmentation and concomitant implant placement in low bone-density sites. A retrospective study on an undersized drilling protocol and primary stability [J].
Arosio, Paolo ;
Greco, Gian Battista ;
Zaniol, Terry ;
Iezzi, Giovanna ;
Perrotti, Vittoria ;
Di Stefano, Danilo Alessio .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (02) :151-159
[9]   Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis [J].
Atieh, Momen A. ;
Alsabeeha, Nabeel ;
Duncan, Warwick J. .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (04) :634-645
[10]   Primary Stability of Three Different Osteotomy Techniques in Medullary Bone: An in Vitro Study [J].
Attanasio, Ferdinando ;
Antonelli, Alessandro ;
Brancaccio, Ylenia ;
Averta, Fiorella ;
Figliuzzi, Michele Mario ;
Fortunato, Leonzio ;
Giudice, Amerigo .
DENTISTRY JOURNAL, 2020, 8 (01)