Spectroscopy-based multi-parametric quantification in subjects with liver iron overload at 1.5T and 3T

被引:8
作者
Simchick, Gregory [1 ]
Zhao, Ruiyang [1 ,2 ]
Hamilton, Gavin [3 ]
Reeder, Scott B. [1 ,2 ,4 ,5 ,6 ]
Hernando, Diego [1 ,2 ,4 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[3] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[4] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53705 USA
[5] Univ Wisconsin, Dept Med, Madison, WI 53705 USA
[6] Univ Wisconsin, Dept Emergency Med, Madison, WI 53705 USA
关键词
chronic liver disease; iron overload; liver; liver iron concentration; MRS; quantitative; DENSITY FAT-FRACTION; MAGNETIC-RESONANCE; IN-VIVO; HEPATIC STEATOSIS; MRI; DISEASE; T-1; PERFORMANCE; RELAXATION; DIAGNOSIS;
D O I
10.1002/mrm.29021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the precision profile (repeatability and reproducibility) of quantitative STEAM-MRS and to determine the relationships between multiple MR biomarkers of chronic liver disease in subjects with iron overload at both 1.5 Tesla (T) and 3T. Methods MRS data were acquired in patients with known or suspected liver iron overload. Two STEAM-MRS sequences (multi-TE and multi-TE-TR) were acquired at both 1.5T and 3T (same day), including test-retest acquisition. Each acquisition enabled estimation of R1, R2, and FWHM (each separately for water and fat); and proton density fat fraction. The test-retest repeatability and reproducibility across acquisition modes (multi-TE vs. multi-TE-TR) of the estimates were evaluated using intraclass correlation coefficients, linear regression, and Bland-Altman analyses. Multi-parametric relationships between parameters at each field strength, across field strengths, and with liver iron concentration were also evaluated using linear and nonlinear regression. Results Fifty-six (n = 56) subjects (10 to 73 years, 37 males/19 females) were successfully recruited. Both STEAM-MRS sequences demonstrated good-to-excellent precision (intraclass correlation coefficient >= 0.81) for the quantification of R1(water), R2(water), FWHMwater, and proton density fat fraction at both 1.5T and 3T. Additionally, several moderate (R-2 = 0.50 to 0.69) to high (R-2 >= 0.70) correlations were observed between biomarkers, across field strengths, and with liver iron concentration. Conclusions Over a broad range of liver iron concentration, STEAM-MRS enables rapid and precise measurement of multiple biomarkers of chronic liver disease. By evaluating the multi-parametric relationships between biomarkers, this work may advance the comprehensive MRS-based assessment of chronic liver disease and may help establish biomarkers of chronic liver disease.
引用
收藏
页码:597 / 613
页数:17
相关论文
共 57 条
  • [31] Use of voigt lineshape for Quantification of in vivo H-1 spectra
    Marshall, I
    Higinbotham, J
    Bruce, S
    Freise, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) : 651 - 657
  • [32] T2*Relaxation Time Obtained from Magnetic Resonance Imaging of the Liver Is a Useful Parameter for Use in the Construction of a Murine Model of Iron Overload
    Matsuo-Tezuka, Yukari
    Sasaki, Yusuke
    Iwai, Toshiki
    Kurasawa, Mitsue
    Yorozu, Keigo
    Tashiro, Yoshihito
    Hirata, Michinori
    [J]. CONTRAST MEDIA & MOLECULAR IMAGING, 2019, 2019
  • [33] Multiparametric magnetic resonance imaging for quantitation of liver disease: a two-centre cross-sectional observational study
    McDonald, Natasha
    Eddowes, Peter J.
    Hodson, James
    Semple, Scott I. K.
    Davies, Nigel P.
    Kelly, Catherine J.
    Kin, Stella
    Phillips, Miranda
    Herlihy, Amy H.
    Kendall, Timothy J.
    Brown, Rachel M.
    Neil, Desley A. H.
    Hubscher, Stefan G.
    Hirschfield, Gideon M.
    Fallowfield, Jonathan A.
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [34] Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy
    Meisamy, Sina
    Hines, Catherine D. G.
    Hamilton, Gavin
    Sirlin, Claude B.
    McKenzie, Charles A.
    Yu, Huanzhou
    Brittain, Jean H.
    Reeder, Scott B.
    [J]. RADIOLOGY, 2011, 258 (03) : 767 - 775
  • [35] Reference range of liver corrected T1 values in a population at low risk for fatty liver diseasea UK Biobank sub-study, with an appendix of interesting cases
    Mojtahed, A.
    Kelly, C. J.
    Herlihy, A. H.
    Kin, S.
    Wilman, H. R.
    McKay, A.
    Kelly, M.
    Milanesi, M.
    Neubauer, S.
    Thomas, E. L.
    Bell, J. D.
    Banerjee, R.
    Harisinghani, M.
    [J]. ABDOMINAL RADIOLOGY, 2019, 44 (01) : 72 - 84
  • [36] Moonen C T, 1989, NMR Biomed, V2, P201, DOI 10.1002/nbm.1940020506
  • [37] Imaging of diffuse liver disease
    Mortele, KJ
    Ros, PR
    [J]. SEMINARS IN LIVER DISEASE, 2001, 21 (02) : 195 - 212
  • [38] Utility of MR proton density fat fraction and its correlation with ultrasonography and biochemical markers in nonalcoholic fatty liver disease in overweight adolescents
    Netaji, Arjunlokesh
    Jain, Vandana
    Gupta, Arun Kumar
    Kumar, Udit
    Jana, Manisha
    [J]. JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2020, 33 (04) : 473 - 479
  • [39] Liver Biopsy Analysis Has a Low Level of Performance for Diagnosis of Intermediate Stages of Fibrosis
    Poynard, Thierry
    Lenaour, Gilles
    Vaillant, Jean Christophe
    Capron, Frederique
    Munteanu, Mona
    Eyraud, Daniel
    Ngo, Yen
    M'Kada, Helmi
    Ratziu, Vlad
    Hannoun, Laurent
    Charlotte, Frederic
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2012, 10 (06) : 657 - 663
  • [40] MR Spectroscopy of the Liver: Principles and Clinical Applications
    Qayyum, Aliya
    [J]. RADIOGRAPHICS, 2009, 29 (06) : 1653 - U142