Handheld fetal Doppler device for assessing heart rate in neonatal resuscitation

被引:8
|
作者
Shimabukuro, Rinshu [1 ,2 ]
Takase, Kozo [2 ]
Ohde, Sachiko [3 ]
Kusakawa, Isao [1 ]
机构
[1] Tokyo Med & Dent Univ, St Lukes Int Hosp, Dept Pediat, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Div Publ Hlth, Dept Res Dev, Tokyo, Japan
[3] St Lukes Int Univ, Grad Sch Publ Hlth, Planning Off, Ctr Clin Epidemiol, Tokyo, Japan
关键词
electrocardiogram; fetal Doppler; heart rate; neonate; resuscitation; OXIMETRY;
D O I
10.1111/ped.13374
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundThe use of neonatal three-lead electrocardiograms (Neo-ECG) is suggested for the assessment of heart rate (HR) in neonatal resuscitation, but primary childbirth facilities (i.e. maternity clinics or maternity homes) are not sufficiently equipped for this. The aim of this study was to therefore to confirm the potential of a handheld fetal Doppler device (FDD), widely used to assess HR in labor room resuscitation, and to compare its equivalency to Neo-ECG. MethodsIn low-risk full-term infants, HR was measured five times per minute in minutes 1-5 after delivery using the FDD and Neo-ECG, and their equivalence compared. The equivalence margin was set at a HR difference of <5 beats/min and <5%. Moreover, the times at which HR was displayed were measured for both methods. ResultsFDD and Neo-ECG HR correlated strongly (r = 0.977) in 155 measurements in 33 cases. The mean HR difference was -0.123 beats/min (95%CI: -0.594 to +0.345), and the logarithmic transformation of the HR ratio was -0.0003 (95%CI: -0.0020 to +0.0015). The mean HR difference and HR ratio were within the equivalence margin. For HR assessment using the FDD, 155 of 165 measurements (93.9%) could be obtained in <10 s. ConclusionsIn HR assessment, FDD is a valid substitute for Neo-ECG in primary childbirth facilities that are not sufficiently equipped for Neo-ECG.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 50 条
  • [41] 2005 American Heart Association (AHA) guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care (ECC) of pediatric and neonatal patients: Neonatal resuscitation guidelines
    Kattwinkel, J
    Perlman, JM
    Boyle, D
    Engle, WA
    Escobedo, M
    Goldsmith, JP
    Halamek, LP
    McGowan, J
    Singhal, N
    Weiner, GM
    Wiswell, T
    Zaichkin, J
    Simon, WM
    PEDIATRICS, 2006, 117 (05) : E1029 - E1038
  • [42] Assessing Fetal Circulatory Changes in Gestational Diabetes via Aortic Isthmus Doppler
    Chen, Xingxing
    Zhang, Lili
    Lu, Jiajia
    Shen, Lijun
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2024, 51 (09)
  • [43] Electrocardiographic dynamic development and heart rate variability in lambs during the neonatal period
    Chiacchio, Simone Biagio
    Vela Ulian, Carla Maria
    Goncalves, Renato de Souza
    Padovani, Carlos Roberto
    Salgueiro Cruz, Raissa Karolliny
    Santarosa, Bianca Paola
    Alfonso, Angelica
    Gomes Lourenco, Maria Lucia
    JOURNAL OF APPLIED ANIMAL RESEARCH, 2018, 46 (01) : 1137 - 1143
  • [44] An open source autocorrelation-based method for fetal heart rate estimation from one-dimensional Doppler ultrasound
    Valderrama, Camilo E.
    Stroux, Lisa
    Katebi, Nasim
    Paljug, Elianna
    Hall-Clifford, Rachel
    Rohloff, Peter
    Marzbanrad, Faezeh
    Clifford, Gari D.
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (02)
  • [45] 2019 American Heart Association Focused Update on Neonatal Resuscitation An Update to the American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care
    Escobedo, Marilyn B.
    Aziz, Khalid
    Kapadia, Vishal S.
    Lee, Henry C.
    Niermeyer, Susan
    Schmolzer, Georg M.
    Szyld, Edgardo
    Weiner, Gary M.
    Wyckoff, Myra H.
    Yamada, Nicole K.
    Zaichkin, Jeanette G.
    CIRCULATION, 2019, 140 (24) : E922 - E930
  • [46] Functionality and acceptability of a novel non-invasive neonatal heart rate monitoring device: a qualitative study of healthcare professionals
    Anton, Oana
    Fernandez, Ramon
    Rendon-Morales, Elizabeth
    Aviles-Espinosa, Rodrigo
    Jones, Christina J.
    Rabe, Heike
    BMJ INNOVATIONS, 2020, 6 (04) : 143 - 150
  • [47] Who's counting? Assessing the effects of a simulation-based training intervention on the accuracy of neonatal heart rate auscultation
    Money, Nathan
    Kusheleva, Natalya
    Ruano, Susana
    Demissie, Seleshi
    Blau, Jonathan
    Singhi, Vinisha
    JOURNAL OF PERINATOLOGY, 2019, 39 (05) : 634 - 639
  • [48] The accuracy of human senses in the detection of neonatal heart rate during standardized simulated resuscitation: Implications for delivery of care, training and technology design
    Chitkara, Ritu
    Rajani, Anand K.
    Oehlert, John W.
    Lee, Henry C.
    Epi, M. S.
    Halamek, Louis P.
    RESUSCITATION, 2013, 84 (03) : 369 - 372
  • [49] A Problem of Maternal and Fetal QRS Complexes Overlapping in Fetal Heart Rate Estimation
    Jezewski, Janusz
    Kupka, Tomasz
    Horoba, Krzysztof
    Czabanski, Robert
    Wrobel, Janusz
    SELECTED TOPICS IN APPLIED COMPUTER SCIENCE, 2010, : 122 - 127
  • [50] Forehead monitoring of heart rate in neonatal intensive care
    Stockwell, S. J.
    Kwok, T. C.
    Morgan, S. P.
    Sharkey, D.
    Hayes-Gill, B. R.
    FRONTIERS IN PHYSIOLOGY, 2023, 14