Handheld fetal Doppler device for assessing heart rate in neonatal resuscitation

被引:8
|
作者
Shimabukuro, Rinshu [1 ,2 ]
Takase, Kozo [2 ]
Ohde, Sachiko [3 ]
Kusakawa, Isao [1 ]
机构
[1] Tokyo Med & Dent Univ, St Lukes Int Hosp, Dept Pediat, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Div Publ Hlth, Dept Res Dev, Tokyo, Japan
[3] St Lukes Int Univ, Grad Sch Publ Hlth, Planning Off, Ctr Clin Epidemiol, Tokyo, Japan
关键词
electrocardiogram; fetal Doppler; heart rate; neonate; resuscitation; OXIMETRY;
D O I
10.1111/ped.13374
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundThe use of neonatal three-lead electrocardiograms (Neo-ECG) is suggested for the assessment of heart rate (HR) in neonatal resuscitation, but primary childbirth facilities (i.e. maternity clinics or maternity homes) are not sufficiently equipped for this. The aim of this study was to therefore to confirm the potential of a handheld fetal Doppler device (FDD), widely used to assess HR in labor room resuscitation, and to compare its equivalency to Neo-ECG. MethodsIn low-risk full-term infants, HR was measured five times per minute in minutes 1-5 after delivery using the FDD and Neo-ECG, and their equivalence compared. The equivalence margin was set at a HR difference of <5 beats/min and <5%. Moreover, the times at which HR was displayed were measured for both methods. ResultsFDD and Neo-ECG HR correlated strongly (r = 0.977) in 155 measurements in 33 cases. The mean HR difference was -0.123 beats/min (95%CI: -0.594 to +0.345), and the logarithmic transformation of the HR ratio was -0.0003 (95%CI: -0.0020 to +0.0015). The mean HR difference and HR ratio were within the equivalence margin. For HR assessment using the FDD, 155 of 165 measurements (93.9%) could be obtained in <10 s. ConclusionsIn HR assessment, FDD is a valid substitute for Neo-ECG in primary childbirth facilities that are not sufficiently equipped for Neo-ECG.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 50 条
  • [21] Improvements in fetal heart rate analysis by the removal of maternal-fetal heart rate ambiguities
    Paula Pinto
    Cristina Costa-Santos
    Hernâni Gonçalves
    Diogo Ayres-De-Campos
    João Bernardes
    BMC Pregnancy and Childbirth, 15
  • [22] Assessing the Accuracy of Popular Commercial Technologies That Measure Resting Heart Rate and Heart Rate Variability
    Stone, Jason D.
    Ulman, Hana K.
    Tran, Kaylee
    Thompson, Andrew G.
    Halter, Manuel D.
    Ramadan, Jad H.
    Stephenson, Mark
    Finomore, Victor S., Jr.
    Galster, Scott M.
    Rezai, Ali R.
    Hagen, Joshua A.
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2021, 3
  • [23] A Hybrid EMD-Kurtosis Method for Estimating Fetal Heart Rate from Continuous Doppler Signals
    Al-Angari, Haitham M.
    Kimura, Yoshitaka
    Hadjileontiadis, Leontios J.
    Khandoker, Ahsan H.
    FRONTIERS IN PHYSIOLOGY, 2017, 8
  • [24] New Method for Beat-to-Beat Fetal Heart Rate Measurement Using Doppler Ultrasound Signal
    Kupka, Tomasz
    Matonia, Adam
    Jezewski, Michal
    Jezewski, Janusz
    Horoba, Krzysztof
    Wrobel, Janusz
    Czabanski, Robert
    Martinek, Radek
    SENSORS, 2020, 20 (15) : 1 - 25
  • [25] On the Fetal Heart Rate Diagnostic Technologies
    Nassit, Mariame
    Berbia, Hassan
    2015 10TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS: THEORIES AND APPLICATIONS (SITA), 2015,
  • [26] Significance of Neonatal Heart Rate in the Delivery Room-A Review
    Nerdrum Aagaard, Ellisiv
    Solevag, Anne Lee
    Saugstad, Ola Didrik
    CHILDREN-BASEL, 2023, 10 (09):
  • [27] Evaluation of a Tap-Based Smartphone App for Heart Rate Assessment During Asphyxia in a Porcine Model of Neonatal Resuscitation
    Johnson, Peter A.
    Morina, Nicolo
    O'Reilly, Megan
    Lee, Tze-Fun
    Cheung, Po-Yin
    Schmolzer, Georg M.
    FRONTIERS IN PEDIATRICS, 2019, 7
  • [28] Would omitting the assessment of heart rate be harmful to initial neonatal care?
    Minami, Kojiro
    Furuhashi, Madoka
    Miyazaki, Ken
    Yoshida, Kana
    Kuno, Naohiko
    Ishikawa, Kaoru
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2007, 20 (06) : 477 - 480
  • [29] The BabySaver: Design of a New Device for Neonatal Resuscitation at Birth with Intact Placental Circulation
    Ditai, James
    Barry, Aisling
    Burgoine, Kathy
    Mbonye, Anthony K.
    Wandabwa, Julius N.
    Watt, Peter
    Weeks, Andrew D.
    CHILDREN-BASEL, 2021, 8 (06):
  • [30] Interventions for Intrapartum Fetal Heart Rate Abnormalities
    Eller, Alexandra G.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2020, 63 (03) : 635 - 644