Improved lateral force calibration based on the angle conversion factor in atomic force microscopy

被引:19
作者
Choi, Dukhyun
Hwang, Woonbong
Yoon, Euisung
机构
[1] Pohang Inst Sci & Technol, Dept Mech Engn, Pohang 790784, South Korea
[2] Korea Inst Sci & Technol, Tribol Lab, Seoul 130650, South Korea
关键词
angle conversion factor; atomic force microscopy; coefficient of friction; lateral force calibration; lateral force calibration factor; mica; twist angle;
D O I
10.1111/j.1365-2818.2007.01837.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
A novel calibration method is proposed for determining lateral forces in atomic force microscopy (AFM), by introducing an angle conversion factor, which is defined as the ratio of the twist angle of a cantilever to the corresponding lateral signal. This factor greatly simplifies the calibration procedures. Once the angle conversion factor is determined in AFM, the lateral force calibration factors of any rectangular cantilever can be obtained by simple computation without further experiments. To determine the angle conversion factor, this study focuses on the determination of the twist angle of a cantilever during lateral force calibration in AFM. Since the twist angle of a cantilever cannot be directly measured in AFM, the angles are obtained by means of the moment balance equations between a rectangular AFM cantilever and a simple commercially available step grating. To eliminate the effect of the adhesive force, the gradients of the lateral signals and the twist angles as a function of normal force are used in calculating the angle conversion factor. To verify reliability and reproducibility of the method, two step gratings with different heights and two different rectangular cantilevers were used in lateral force calibration in AFM. The results showed good agreement, to within 10%. This method was validated by comparing the coefficient of friction of mica so determined with values in the literature.
引用
收藏
页码:190 / 199
页数:10
相关论文
共 35 条
  • [1] Beer FP, 1992, MECH MAT
  • [2] ATOMIC FORCE MICROSCOPE
    BINNIG, G
    QUATE, CF
    GERBER, C
    [J]. PHYSICAL REVIEW LETTERS, 1986, 56 (09) : 930 - 933
  • [3] Tip friction - torsional spring constant determination
    Bogdanovic, G
    Meurk, A
    Rutland, MW
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2000, 19 (04) : 397 - 405
  • [4] Atomic force microscopy calibration methods for lateral force, elasticity, and viscosity
    Buenviaje, CK
    Ge, SR
    Rafailovich, MH
    Overney, RM
    [J]. FUNDAMENTALS OF NANOINDENTATION AND NANOTRIBOLOGY, 1998, 522 : 187 - 192
  • [5] Force calibration in lateral force microscopy
    Cain, RG
    Biggs, S
    Page, NW
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2000, 227 (01) : 55 - 65
  • [6] Quantitative comparison of three calibration techniques for the lateral force microscope
    Cain, RG
    Reitsma, MG
    Biggs, S
    Page, NW
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (08) : 3304 - 3312
  • [7] Lateral force calibration in atomic force microscopy: A new lateral force calibration method and general guidelines for optimization
    Cannara, Rachel J.
    Eglin, Michael
    Carpick, Robert W.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (05)
  • [8] CARNDALL SH, 1978, INTRO MECH SOLIDS
  • [9] Lateral stiffness: A new nanomechanical measurement for the determination of shear strengths with friction force microscopy
    Carpick, RW
    Ogletree, DF
    Salmeron, M
    [J]. APPLIED PHYSICS LETTERS, 1997, 70 (12) : 1548 - 1550
  • [10] A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY
    CLEVELAND, JP
    MANNE, S
    BOCEK, D
    HANSMA, PK
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) : 403 - 405