Transfracture medial transposition of the radial nerve associated with plate fixation of the humerus

被引:8
作者
Chamseddine, Ali Hassan [1 ,2 ]
Abdallah, Amer [1 ]
Zein, Hadi [1 ,2 ]
Taha, Assad [3 ]
机构
[1] Lebanese Univ, Fac Med Sci, Div Orthopaed & Trauma Surg, Beirut, Lebanon
[2] Univ Med Ctr, Sahel Gen Hospital, Div Orthopaed & Trauma Surg, POB 99-25, Beirut, Lebanon
[3] Amer Univ Beirut, Med Ctr, Div Orthopaed Surg, Beirut, Lebanon
关键词
Humeral shaft fracture; Open reduction and internal fixation; Humerusnonunion; Radial nerve; Radial nerve transposition; ANTERIOR TRANSPOSITION; FRACTURES; SHAFT; LESIONS; PALSY;
D O I
10.1007/s00264-016-3397-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The aim of this study was to illustrate safety, feasibility and advantages of transfracture medial transposition of the radial nerve during the lateral approach and lateral plating of humeral fractures located in the mid and distal shaft. Methods This was a retrospective review and analysis of medical records and radiographs of 19 patients who underwent a transfracture medial transposition of the radial nerve. Fifteen patients were treated for fresh fracture and four for nonunion. All patients were followed up clinically and radiographically for a minimum of 12 months. Results Pre-operative radial nerve paralysis was present in four patients in the fresh fractures group; post-operative paralysis occurred in two. All patients completely recovered a few months after the index procedure. Except for two, all patients achieved bone healing. One patient from the fresh-fracture group developed nonunion, and one from the nonunion group experienced persistent nonunion; both underwent successful revision surgeries. In addition, four patients with a fresh fracture underwent revision surgery for hardware removal. All but two patients showed no restricted elbow or shoulder joint motion compared with the opposite side. Conclusion Transfracture transposition of the radial nerve during open reduction and internal fixation of humeral shaft fractures is a safe, harmless and feasible procedure when applied for fractures of the middle and distal humeral shaft; it removes the nerve from the surgical field during fracture manipulation and fixation, with a gain in length of the nerve by transforming its course from spiral to straight. Following radial nerve transposition across the fracture, a repeat surgical approach to the humerus for hardware removal or treatment of nonunion transforms the procedure into a simple one; the skin incision is carried straight down to the bone without the need to identify or dissect the nerve that was previously transposed to the medial compartment of the arm.
引用
收藏
页码:1463 / 1470
页数:8
相关论文
共 22 条
[1]  
ALNOT JY, 1989, REV CHIR ORTHOP, V75, P433
[2]   Medial transposition of the radial nerve for anterolateral plate fixation of the humerus: Cadaveric study [J].
Bacakoglu, Abdul Kadir ;
Kiray, Amac ;
Muratli, Kivanc ;
Ekin, Ahmet ;
Ergur, Ipek .
ANATOMICAL SCIENCE INTERNATIONAL, 2007, 82 (02) :116-120
[3]  
BEZES H, 1995, INT ORTHOP, V19, P16
[4]  
BONNEVIALLE P, 1996, CAHIERS ENSEIGNEMENT, P79
[5]  
BOSTMAN O, 1986, ACTA ORTHOP SCAND, V57, P316
[6]   Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate [J].
Capo, John T. ;
Debkowska, Monika P. ;
Liporace, Frank ;
Beutel, Bryan G. ;
Melamed, Eitan .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (05) :1037-1043
[7]   Trans-fracture transposition of the radial nerve during the open approach of humeral shaft fractures [J].
Chamseddine A.H. ;
Zein H.K. ;
Alasiry A.A. ;
Mansour N.A. ;
Bazzal A.M. .
European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (6) :725-730
[8]  
Dayez J, 1999, REV CHIR ORTHOP, V85, P238
[9]  
El Ayoubi L, 2003, REV CHIR ORTHOP, V89, P537
[10]  
GUSE TR, 1995, CLIN ORTHOP RELAT R, P149