SMARTDIAB: A Communication and Information Technology Approach for the Intelligent Monitoring, Management and Follow-up of Type 1 Diabetes Patients

被引:52
作者
Mougiakakou, Stavroula G. [1 ]
Bartsocas, Christos S. [2 ,3 ]
Bozas, Evangelos [4 ]
Chaniotakis, Nikos [5 ]
Iliopoulou, Dimitra [6 ]
Kouris, Ioannis [6 ]
Pavlopoulos, Sotiris [1 ]
Prountzou, Aikaterini [6 ]
Skevofilakas, Marios [6 ]
Tsoukalis, Alexandre [7 ]
Varotsis, Kostas [5 ]
Vazeou, Andrianni [8 ]
Zarkogianni, Konstantia [6 ]
Nikita, Konstantina S. [6 ]
机构
[1] Natl Tech Univ Athens, Inst Commun & Comp Syst, Athens 15780, Greece
[2] MITERA Gen Matern, Maroussi 15123, Greece
[3] Childrens Hosp, Maroussi 15123, Greece
[4] Natl & Kapodistrian Univ Athens, Fac Nursing, Sch Hlth Sci, Athens 11527, Greece
[5] Univ Crete, Dept Chem, Iraklion 71409, Greece
[6] Natl Tech Univ Athens, Sch Elect & Comp Engn, Athens 15780, Greece
[7] Micrel Med Devices, Pallini 15351, Greece
[8] PA Kyriakou Childrens Hosp, Dept Pediat, Ctr Diabet, Athens 11527, Greece
来源
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE | 2010年 / 14卷 / 03期
关键词
Closed-loop glucose control; diabetes management; home care; information and communication technologies; telemedicine; PREDICTIVE CONTROL; GLUCOSE; INSULIN; SIMULATION; MODEL; TELEMEDICINE; MELLITUS; SYSTEM;
D O I
10.1109/TITB.2009.2039711
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
SMARTDIAB is a platform designed to support the monitoring, management, and treatment of patients with type 1 diabetes mellitus (T1DM), by combining state-of-the-art approaches in the fields of database (DB) technologies, communications, simulation algorithms, and data mining. SMARTDIAB consists mainly of two units: 1) the patient unit (PU); and 2) the patient management unit (PMU), which communicate with each other for data exchange. The PMU can be accessed by the PU through the internet using devices, such as PCs/laptops with direct internet access or mobile phones via a Wi-Fi/General Packet Radio Service access network. The PU consists of an insulin pump for subcutaneous insulin infusion to the patient and a continuous glucose measurement system. The aforementioned devices running a user-friendly application gather patient's related information and transmit it to the PMU. The PMU consists of a diabetes data management system (DDMS), a decision support system (DSS) that provides risk assessment for long-term diabetes complications, and an insulin infusion advisory system (IIAS), which reside on a Web server. The DDMS can be accessed from both medical personnel and patients, with appropriate security access rights and front-end interfaces. The DDMS, apart from being used for data storage/retrieval, provides also advanced tools for the intelligent processing of the patient's data, supporting the physician in decision making, regarding the patient's treatment. The IIAS is used to close the loop between the insulin pump and the continuous glucose monitoring system, by providing the pump with the appropriate insulin infusion rate in order to keep the patient's glucose levels within predefined limits. The pilot version of the SMARTDIAB has already been implemented, while the platform's evaluation in clinical environment is being in progress.
引用
收藏
页码:622 / 633
页数:12
相关论文
共 49 条
[1]  
Andre David, 2007, J Diabetes Sci Technol, V1, P760
[2]   A telemedicine support for diabetes management: the T-IDDM project [J].
Bellazzi, R ;
Larizza, C ;
Montani, S ;
Riva, A ;
Stefanelli, M ;
d'Annunzio, G ;
Lorini, R ;
Gomez, EJ ;
Hernando, E ;
Brugues, E ;
Cermeno, J ;
Corcoy, R ;
de Leiva, A ;
Cobelli, C ;
Nucci, G ;
Del Prato, S ;
Maran, A ;
Kilkki, E ;
Tuominen, J .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2002, 69 (02) :147-161
[3]   Web-based telemedicine systems for home-care: technical issues and experiences [J].
Bellazzi, R ;
Montani, S ;
Riva, A ;
Stefanelli, M .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2001, 64 (03) :175-187
[4]  
BELLAZZI R, P 1996 AMIA ANN FALL, P194
[5]  
Bellazzi Riccardo, 2008, J Diabetes Sci Technol, V2, P98
[6]  
Bequette B Wayne, 2005, Diabetes Technol Ther, V7, P28, DOI 10.1089/dia.2005.7.28
[7]   COMPUTER-SIMULATION OF PLASMA-INSULIN AND GLUCOSE DYNAMICS AFTER SUBCUTANEOUS INSULIN INJECTION [J].
BERGER, M ;
RODBARD, D .
DIABETES CARE, 1989, 12 (10) :725-736
[8]   Application of irregular and unbalanced data to predict diabetic nephropathy using visualization and feature selection methods [J].
Cho, Baek Hwan ;
Yu, Hwanjo ;
Kim, Kwang-Won ;
Kim, Tae Hyun ;
Kim, In Young ;
Kim, Sun I. .
ARTIFICIAL INTELLIGENCE IN MEDICINE, 2008, 42 (01) :37-53
[9]   GENERALIZED PREDICTIVE CONTROL .1. THE BASIC ALGORITHM [J].
CLARKE, DW ;
MOHTADI, C ;
TUFFS, PS .
AUTOMATICA, 1987, 23 (02) :137-148
[10]  
Cook Curtiss B, 2005, Diabetes Technol Ther, V7, P58, DOI 10.1089/dia.2005.7.58