摘要
We present a detailed experimental study of a new through-focus technique to measure critical dimension linewidth with nanometer sensitivity using a bright field optical microscope. This method relies on analyzing intensity gradients in optical images at different focus positions, here defined as the focus metric (FM) signature. The contrast of an optical image of a structured target, where a particular structure is repeated several times, varies greatly as it is moved through-focus if the spacing between the structures is such that the scattered field from the features interferes. Complex, distinguishable through-focus optical response occurs under this condition giving rise to the formation of several cyclic high and low contrast images. As a result it exhibits several FM signature peaks as opposed to a single FM peak for structures nearly isolated. This complex optical behavior is very sensitive to the dimensions of the target geometry. By appropriately analyzing the through-focus optical image, information can be obtained regarding the target. An array of lines is used as a structured target. Linewidth measurements were made by using experimental through-focus optical data obtained using a bright field microscope and simulated optical data. The optical results are compared with reference metrology tools such as a critical dimension atomic force microscope and critical dimension scanning electron microscope. (c) 2008 Optical Society of America.
引用
收藏
页码:495 / 503
页数:9
相关论文
共 21 条
[1]   Application of through-focus focus-metric analysis in high resolution optical metrology [J].
Attota, R ;
Silver, RM ;
Germer, TA ;
Bishop, M .
Metrology, Inspection, and Process Control for Microlithography XIX, Pts 1-3, 2005, 5752 :1441-1449
[2]   Evaluation of new in-chip and arrayed line overlay target designs [J].
Attota, R ;
Silver, RM ;
Bishop, M ;
Marx, E ;
Jun, J ;
Stocker, M ;
Davidson, M ;
Larrabee, R .
METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XVIII, PTS 1 AND 2, 2004, 5375 :395-402
[3]   Optical illumination and critical dimension analysis using the through-focus focus metric method [J].
Attota, Ravikiran ;
Silver, Richard M. ;
Potzick, James .
NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION IX, 2006, 6289
[4]   ANALYTIC WAVE-GUIDE SOLUTIONS AND THE COHERENCE PROBE MICROSCOPE [J].
DAVIDSON, MP .
MICROELECTRONIC ENGINEERING, 1991, 13 (1-4) :523-526
[5]   Traceable calibration of critical-dimension atomic force microscope linewidth measurements with nanometer uncertainty [J].
Dixson, RG ;
Allen, RA ;
Guthrie, WF ;
Cresswell, MW .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2005, 23 (06) :3028-3032
[6]   Focus and edge detection algorithms and their relevance to the development of an optical overlay calibration standard [J].
Fox, S ;
Silver, RM ;
Kornegay, E ;
Dagenais, M .
METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XIII, PTS 1 AND 2, 1999, 3677 :95-106
[7]  
GERMER TA, 2007, P SOC PHOTO-OPT INS, V6152
[8]  
KROTKOV E, 1987, INT J COMPUT VISION, V1, P223, DOI 10.1007/BF00127822
[9]   Through-focus technique for grating linewidth analysis with nanometer sensitivity [J].
Ku, Yi-Sha ;
Liu, An-Shun ;
Smith, Nigel .
OPTICAL ENGINEERING, 2006, 45 (12)
[10]   Through-focus technique for nano-scale grating pitch and linewidth analysis [J].
Ku, YS ;
Liu, AS ;
Smith, N .
OPTICS EXPRESS, 2005, 13 (18) :6699-6708