Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery: An updated meta-analysis

被引:65
作者
Zhao, Yang [1 ]
Yang, Ke [1 ]
Li, Jiaxin [2 ]
Huang, Yang [3 ]
Zhu, Siquan [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Beijing Key Lab Ophthalmol & Visual Sci, Beijing Tongren Eye Ctr, 1 Dongjiaominxiang Dongcheng Dist, Beijing 100073, Peoples R China
[2] Pingdingshan Univ, Med Sch, Pingdingshan, Peoples R China
[3] Chinese Peoples Liberat Army, Gen Hosp, Dept Ophthalmol, Beijing, Peoples R China
关键词
biomaterial; cataract; hydrophilic; hydrophobic; intraocular lens; Nd:YAG laser capsulotomy; posterior capsule opacification; 2-YEAR FOLLOW-UP; RATES; IMPLANTATION; HYDROGEL; SILICONE; ACRYSOF; DESIGN;
D O I
10.1097/MD.0000000000008301
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO.Methods:Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies.Results:Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR)=0.38, 95% confidence interval (95% CI)=0.16-0.91, P=.029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: -1.32, 95% CI=-2.39 to -0.25, P=.015) and estimated PCO score (diff. in means: -2.23; 95% CI, -3.80 to -0.68, P=.005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: -0.075; 95% CI, -0.18 to 0.035; P=.182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: -0.016; 95% CI, -0.041 to 0.009, P=.208).Conclusion:In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity.
引用
收藏
页数:9
相关论文
共 26 条
[1]   Eradication of posterior capsule opacification -: Documentation. of a marked decrease in Nd:YAG laser posterior capsulotomy rates noted in an analysis of 5416 pseudophakic human eyes obtained postmortem [J].
Apple, DJ ;
Peng, Q ;
Visessook, N ;
Werner, L ;
Pandey, SK ;
Escobar-Gomez, M ;
Ram, J ;
Auffarth, GU .
OPHTHALMOLOGY, 2001, 108 (03) :505-518
[2]   Posterior capsule opacification and Nd:YAG capsulotomy rates after implantation of silicone, hydrogel and soft acrylic intraocular lenses:: a two-year follow-up study [J].
Beltrame, G ;
Salvetat, ML ;
Chizzolini, M ;
Driussi, GB ;
Busatto, P ;
Di Giorgio, G ;
Barosco, F .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2002, 12 (05) :388-394
[3]   Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification [J].
Buehl, W ;
Findl, O ;
Menapace, R ;
Sacu, S ;
Kriechbaum, K ;
Koeppl, C ;
Wirtitsch, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :954-961
[4]   Effect of intraocular lens design on posterior capsule opacification [J].
Buehl, Wolf ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11) :1976-1985
[5]   Posterior capsule opacification 9 years after phacoemulsification with a hydrophobic and a hydrophilic intraocular lens [J].
Chang, Anthony ;
Kugelberg, Maria .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (02) :164-168
[6]   Efficacy of different intraocular lens materials and optic edge designs in preventing posterior capsular opacification: A meta-analysis [J].
Cheng, Jin-Wei ;
Wei, Rui-Li ;
Cai, Ji-Ping ;
Xi, Gui-Lin ;
Zhu, Huang ;
Li, You ;
Ma, Xiao-Ye .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (03) :428-436
[7]   Randomized intraindividual comparison of posterior capsule opacification between a microincision intraocular lens and a conventional intraocular lens [J].
Cleary, Georgia ;
Spalton, David J. ;
Hancox, Joanne ;
Boyce, James ;
Marshall, John .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02) :265-272
[8]   Proposed pathogenesis for the delayed postoperative opacification of the hydroview hydrogel intraocular lens [J].
Dorey, MW ;
Brownstein, S ;
Hill, VE ;
Mathew, B ;
Botton, G ;
Kertes, PJ ;
El-Defrawy, S .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (05) :591-598
[9]   Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics - Randomized clinical trial [J].
Findl, O ;
Menapace, R ;
Sacu, S ;
Buehl, W ;
Rainer, G .
OPHTHALMOLOGY, 2005, 112 (01) :67-72
[10]   Interventions for preventing posterior capsule opacification [J].
Findl, Oliver ;
Buehl, Wolf ;
Bauer, Peter ;
Sycha, Thomas .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2010, (02)