Evaluation of mechanical and corrosion biocompatibility of TiTa alloys

被引:57
作者
Trillo, EA [1 ]
Ortiz, C [1 ]
Dickerson, P [1 ]
Villa, R [1 ]
Stafford, SW [1 ]
Murr, LE [1 ]
机构
[1] Univ Texas, Dept Met & Mat Engn, El Paso, TX 79968 USA
关键词
D O I
10.1023/A:1011210101895
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As-received and heat-treated Ti40Ta and Ti50Ta alloys were evaluated to determine their corrosion as well as mechanical performances and compared to Ti6A14V, a common material utilized for orthopedic (surgical) implants. Anodic potentiodynamic tests performed in Plasmalyte(TM) showed that all samples, except for the Ti50Ta specimen aged at 400 degreesC for 3 h gave a curve similar to that of Ti6A14V. Optical and TEM microscopy was performed to determine as-received and heat-treated microstructures. As-received materials showed an alpha precipitate in an alpha+beta and martensite matrix. Samples that were aged at 400 degreesC increased in the density and the length of the alpha precipitate. Vickers hardness measurements were performed to get an approximation of the tensile strengths. Aged Ti40Ta and Ti50Ta specimens produced the highest tensile values when compared to the Ti6A14V material, representing a 31% and 56% increase for the 3 h samples and an 18% and 58% increase for the 10 h samples. Of all the materials studied the Ti50Ta specimen aged for 10 h exhibited the best biocompatibility showing excellent corrosion resistance combined with the highest tensile strength (1089 MPa and 58% harder/stronger than Ti6A14V). (C) 2001 Kluwer Academic Publishers.
引用
收藏
页码:283 / 292
页数:10
相关论文
共 12 条
  • [1] METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS
    AGINS, HJ
    ALCOCK, NW
    BANSAL, M
    SALVATI, EA
    WILSON, PD
    PELLICCI, PM
    BULLOUGH, PG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) : 347 - 356
  • [2] Bianco PD, 1996, J BIOMED MATER RES, V31, P227
  • [3] Systemic titanium levels in rabbits with a titanium implant in the absence of wear
    Bianco, PD
    Ducheyne, P
    Cuckler, JM
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (09) : 525 - 529
  • [4] DORR LD, 1990, CLIN ORTHOP RELAT R, P82
  • [5] INVIVO METAL-ION RELEASE FROM POROUS TITANIUM-FIBER MATERIAL
    DUCHEYNE, P
    WILLEMS, G
    MARTENS, M
    HELSEN, J
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (03): : 293 - 308
  • [6] FURGUSON AB, 1960, J BONE JT SURG A, V42, P76
  • [7] A NEW BALLOON-EXPANDABLE TANTALUM STENT (STRECKER-STENT) FOR THE BILIARY SYSTEM - PRELIMINARY EXPERIENCE
    JASCHKE, W
    KLOSE, KJ
    STRECKER, EP
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (06) : 356 - 359
  • [8] KARRHOLM J, 1993, T ORTHOP RES SOC, V18, P507
  • [9] CHANGES IN NONOSSEOUS TISSUE ADJACENT TO TITANIUM IMPLANTS
    MEACHIM, G
    WILLIAMS, DF
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (06): : 555 - 572
  • [10] Prigent H, 1998, J BIOMED MATER RES, V39, P200, DOI 10.1002/(SICI)1097-4636(199802)39:2<200::AID-JBM5>3.0.CO