摘要
Abnormal wall thinning of elbows were detected in the economizer at waste heat boiler system. In the failure analysis, material analysis, metallographic examination, macro- and microstructure analysis and composition analysis were conducted. We analyzed the causes and mechanisms of abnormal wall thinning. The failure causes were found to be sulfuric dew point corrosion. Finally, corresponding countermeasures were suggested.
引用
收藏
页数:11
相关论文
共 34 条
  • [1] Failure analysis on abnormal corrosion of economizer tubes in a waste heat boiler
    Ding, Qun
    Tang, Xiao-Feng
    Yang, Zhen-Guo
    ENGINEERING FAILURE ANALYSIS, 2017, 73 : 129 - 138
  • [2] Failure analysis of boiler economizer tubes at power house
    Pal, Urbi
    Kishore, Kaushal
    Mukhopadhyay, Suman
    Mukhopadhyay, Goutam
    Bhattacharya, Sandip
    ENGINEERING FAILURE ANALYSIS, 2019, 104 : 1203 - 1210
  • [3] ANALYSIS OF FIN CHARACTERISTICS FOR OVERALL HEAT TRANSFER IN BOILER ECONOMIZER
    Ganesan, Saravanan Kanthasamy
    Alagesan, Sivapragasam
    Shanmugam, Padmavathy
    Murugan, Sivaraj
    Tufa, Mebratu
    Arockiaraj, Godwin Antony
    THERMAL SCIENCE, 2022, 26 (02): : 849 - 855
  • [4] Failure analysis of superheater tubes in an air quenching cooler waste heat boiler
    Li, Yongjun
    Chen, Hualin
    Pan, Zhi
    Liang, Hanzhao
    Wang, Zhipeng
    Feng, Zongjian
    Li, Zhigang
    Kuang, Yunkun
    ENGINEERING FAILURE ANALYSIS, 2022, 131
  • [5] Failure analysis of primary waste heat boiler tube in ammonia plant
    Ardy, Husaini
    Putra, Yudhistira Perdana
    Anggoro, Adimas Dwi
    Wibowo, Arie
    HELIYON, 2021, 7 (02)
  • [6] Failure analysis of waste heat boiler tubing caused by a high local heat flux
    Suwarno, Suwarno
    I'jazurrohman, Abdul Jabar
    Yudanto, Fajar Dwi
    Djanali, Vivien S.
    ENGINEERING FAILURE ANALYSIS, 2022, 136
  • [7] Failure analysis and acoustic emission tests of an in-service waste heat boiler
    Han, YL
    Zhang, SQ
    Zheng, SJ
    Zhu, WG
    Zhang, B
    ENGINEERING FAILURE ANALYSIS, 2006, 13 (04) : 683 - 697
  • [8] Analysis of failures in boiler tubes due to fireside corrosion in a waste heat recovery boiler
    Srikanth, S
    Ravikumar, B
    Das, SK
    Gopalakrishna, K
    Nandakumar, K
    Vijayan, P
    ENGINEERING FAILURE ANALYSIS, 2003, 10 (01) : 59 - 66
  • [9] Failure Analysis of a Waste Heat Boiler of a Sulfur-Burning Sulfuric Acid Plant
    Wang, Yilin
    Zhang, Ming
    Li, Mengli
    Liu, Long
    Wang, Weiqiang
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2025, 147 (02):
  • [10] Failure Analysis of Welded Joint in Superheater Tube in a Waste Incineration Boiler
    Yongjun Li
    Zhigang Li
    Jiahong Lan
    Hualin Chen
    Zanzan Zhang
    Yezheng Li
    Zongjian Feng
    Shuhai Cen
    Xiaobin Zhang
    Journal of Failure Analysis and Prevention, 2023, 23 : 1452 - 1468