Study of operation strategies for integrating ice-storage district cooling systems into power dispatch for large-scale hydropower utilization

被引:30
作者
Hao, Ling [1 ]
Wei, Mingshan [1 ]
Xu, Fei [2 ]
Yang, Xiaochen [3 ]
Meng, Jia [1 ]
Song, Panpan [1 ]
Min, Yong [2 ]
机构
[1] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
[2] Tsinghua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
[3] Tech Univ Denmark, Dept Civil Engn, Brovej 118, DK-2800 Lyngby, Denmark
关键词
Hydropower utilization; Ice-storage district cooling system; Power dispatch; Smart grid; Power-linked strategy; Cooling pipelines operation strategy; THERMAL-ENERGY STORAGE; SOUTHWESTERN CHINA; COMBINED HEAT; NETWORK; MODEL; OPTIMIZATION; FLEXIBILITY;
D O I
10.1016/j.apenergy.2019.114477
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Hydropower curtailment for the run-of-over stations has become serious in Southwest China. The ice-storage district cooling system is believed as an effective approach to provide flexibility for hydropower utilization. However, the existing ice-storage operation strategies in demand-side management cause that the ice storage cannot be adjusted in real-time to match the surplus hydropower, which brings difficulties for large-scale hydropower utilization. Therefore, this paper proposed the integration of ice-storage district cooling systems into power dispatch based on smart grid. Two operation strategies were developed for the integration to achieve power supply-side management of ice-storage district cooling system. One is the new ice-storage power-linked operation strategy, which was proposed to determine the ice storing/melting capacity in the power dispatch. The other one is the cooling pipelines dynamic-characteristics-considered operation strategy, which was applied in the power dispatch. The dynamic characteristics were calculated based on a linear model to be compatible with the linear constraints in power dispatch models. Finally, effects of two strategies were studied by taking scenes in Chongqing as the example. Results showed that the application of the first strategy only reduces the hydropower curtailment frequency, while application of the second strategy reduces both the curtailment frequency and amount. Furthermore, the simultaneous applications of the above two strategies enhance hydropower consumption by 7.5% (200 million kW.h) and reduce carbon emission by 7.4% (34,000 tons) every year. In addition, there exists an optimal total ice-storage capacity per day, i.e. 8600 MW.h, under which the system's performance reaches the highest value.
引用
收藏
页数:14
相关论文
共 29 条
[1]  
AlHadban Yehya, 2005, DEMAND SIDE MANAGEME
[2]   Changes in extreme wet events in Southwestern China in 1960-2011 [J].
Cao, Liguo ;
Pan, Shaoming ;
Wang, Qiang ;
Wang, Yun ;
Xu, Wei .
QUATERNARY INTERNATIONAL, 2014, 321 :116-124
[3]   Dispatch Model for CHP With Pipeline and Building Thermal Energy Storage Considering Heat Transfer Process [J].
Dai, Yuanhang ;
Chen, Lei ;
Min, Yong ;
Chen, Qun ;
Hao, Junhong ;
Hu, Kang ;
Xu, Fei .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2019, 10 (01) :192-203
[4]  
Dong- Xian Y., 2010, POWER DEMAND SIDE MA, V12, P7
[5]   Optimal operation for integrated energy system considering thermal inertia of district heating network and buildings [J].
Gu, Wei ;
Wang, Jun ;
Lu, Shuai ;
Luo, Zhao ;
Wu, Chenyu .
APPLIED ENERGY, 2017, 199 :234-246
[6]  
[顾泽鹏 Gu Zepeng], 2015, [中国电机工程学报, Proceedings of the Chinese Society of Electrical Engineering], V35, P3596
[7]   A thermal-electrical analogy transient model of district heating pipelines for integrated analysis of thermal and power systems [J].
Hao, Ling ;
Xu, Fei ;
Chen, Qun ;
Wei, Mingshan ;
Chen, Lei ;
Min, Yong .
APPLIED THERMAL ENGINEERING, 2018, 139 :213-221
[8]   Network constrained economic dispatch of integrated heat and electricity systems through mixed integer conic programming [J].
Huang, Shaojun ;
Tang, Weichu ;
Wu, Qiuwei ;
Li, Canbing .
ENERGY, 2019, 179 :464-474
[9]   District heat network as a short-term energy storage [J].
Kouhia, Mikko ;
Laukkanen, Timo ;
Holmberg, Henrik ;
Ahtila, Pekka .
ENERGY, 2019, 177 :293-303
[10]   Combined Heat and Power Dispatch Considering Heat Storage of Both Buildings and Pipelines in District Heating System for Wind Power Integration [J].
Li, Ping ;
Wang, Haixia ;
Lv, Quan ;
Li, Weidong .
ENERGIES, 2017, 10 (07)