Estimation of resting blood pressure using facial thermal images by separating acute stress variations

被引:10
作者
Iwashita, Yuki [1 ]
Nagumo, Kent [1 ]
Oiwa, Kosuke [1 ]
Nozawa, Akio [1 ]
机构
[1] Aoyama Gakuin Univ, Chuo Ku, 5-10-1 Fuchinobe, Sagamihara, Kanagawa, Japan
关键词
Facial thermal image; Independent component analysis; Resting blood pressure; INDEPENDENT COMPONENT ANALYSIS; CIRCADIAN-RHYTHM; ALGORITHM;
D O I
10.1007/s10015-021-00705-y
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
The increasing number of people with hypertension worldwide has become a matter of grave concern. Blood pressure monitoring using a non-contact measurement technique is expected to detect and control this medical condition. Previous studies have estimated blood pressure variations following an acute stress response based on facial thermal images obtained from infrared thermography devices. However, a non-contact resting blood pressure estimation method is required because blood pressure is generally measured in the resting state without inducing acute stress. Day-long blood pressure variations include short-term variations due to acute stress and long-term variations in circadian rhythms. The aim of this study is to estimate resting blood pressure from facial thermal images by separating and excluding short-term variations related to acute stress. To achieve this, short-term blood pressure variations components related to acute stress on facial thermal images were separated using independent component analysis. Resting blood pressure was estimated with the extracted independent components excluding the short-term components using multiple regression analysis. The results show that the proposed approach can accurately estimate resting blood pressure from facial thermal images, with a 9.90 mmHg root mean square error. In addition, features related to resting blood pressure were represented in the nose, lip, and cheek regions.
引用
收藏
页码:473 / 480
页数:8
相关论文
共 27 条
[1]   A SEARCH FOR ARTERIOVENOUS ANASTOMOSES IN HUMAN SKIN USING ULTRASOUND DOPPLER [J].
BERGERSEN, TK .
ACTA PHYSIOLOGICA SCANDINAVICA, 1993, 147 (02) :195-201
[2]   Circadian Clocks, Autonomic Rhythms, and Blood Pressure Dipping [J].
Biaggioni, Italo .
HYPERTENSION, 2008, 52 (05) :797-798
[3]   INDEPENDENT COMPONENT ANALYSIS, A NEW CONCEPT [J].
COMON, P .
SIGNAL PROCESSING, 1994, 36 (03) :287-314
[4]   Continuous Blood Pressure Measurement From Invasive to Unobtrusive: Celebration of 200th Birth Anniversary of Carl Ludwig [J].
Ding, Xiao-Rong ;
Zhao, Ni ;
Yang, Guang-Zhong ;
Pettigrew, Roderic I. ;
Lo, Benny ;
Miao, Fen ;
Li, Ye ;
Liu, Jing ;
Zhang, Yuan-Ting .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (06) :1455-1465
[5]   Global Burden of Hypertension and Systolic Blood Pressure of at Least 110 to 115 mm Hg, 1990-2015 [J].
Forouzanfar, Mohammad H. ;
Liu, Patrick ;
Roth, Gregory A. ;
Ng, Marie ;
Biryukov, Stan ;
Marczak, Laurie ;
Alexander, Lily ;
Estep, Kara ;
Abate, Kalkidan Hassen ;
Akinyemiju, Tomi F. ;
Ali, Raghib ;
Alvis-Guzman, Nelson ;
Azzopardi, Peter ;
Banerjee, Amitava ;
Baernighausen, Till ;
Basu, Arindam ;
Bekele, Tolesa ;
Bennett, Derrick A. ;
Biadgilign, Sibhatu ;
Catala-Lopez, Ferran ;
Feigin, Valery L. ;
Fernandes, Joao C. ;
Fischer, Florian ;
Gebru, Alemseged Aregay ;
Gona, Philimon ;
Gupta, Rajeev ;
Hankey, Graeme J. ;
Jonas, Jost B. ;
Judd, Suzanne E. ;
Khang, Young-Ho ;
Khosravi, Ardeshir ;
Kim, Yun Jin ;
Kimokoti, Ruth W. ;
Kokubo, Yoshihiro ;
Kolte, Dhaval ;
Lopez, Alan ;
Lotufo, Paulo A. ;
Malekzadeh, Reza ;
Melaku, Yohannes Adama ;
Mensah, George A. ;
Misganaw, Awoke ;
Mokdad, Ali H. ;
Moran, Andrew E. ;
Nawaz, Haseeb ;
Neal, Bruce ;
Ngalesoni, Frida Namnyak ;
Ohkubo, Takayoshi ;
Pourmalek, Farshad ;
Rafay, Anwar ;
Rai, Rajesh Kumar .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (02) :165-182
[6]   A fast fixed-point algorithm for independent component analysis [J].
Hyvarinen, A ;
Oja, E .
NEURAL COMPUTATION, 1997, 9 (07) :1483-1492
[7]   Fast and robust fixed-point algorithms for independent component analysis [J].
Hyvärinen, A .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 1999, 10 (03) :626-634
[8]  
Hyvärinen A, 2001, INDEPENDENT COMPONENT ANALYSIS: PRINCIPLES AND PRACTICE, P71
[9]   Independent component analysis for biomedical signals [J].
James, CJ ;
Hesse, CW .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (01) :R15-R39
[10]   Investigating a smartphone imaging unit for photoplethysmography [J].
Jonathan, E. ;
Leahy, Martin .
PHYSIOLOGICAL MEASUREMENT, 2010, 31 (11) :N79-N83