CT and MR imaging of nitinol stents with radiopaque distal markers

被引:29
作者
Létourneau-Guillon, L
Soulez, G
Beaudoin, G
Oliva, VL
Giroux, MF
Qin, Z
Boussion, N
Therasse, T
de Guise, J
Cloutier, G
机构
[1] CHUM, Notre Dame Hosp, Dept Radiol, Montreal, PQ, Canada
[2] CHUM, Notre Dame Hosp, Lab Bioheol & Med Ultrason Res Ctr, Montreal, PQ, Canada
[3] CHUM, Notre Dame Hosp, Lab Orthoped Imaging Res Ctr, Montreal, PQ, Canada
关键词
D O I
10.1097/01.RVI.0000127898.23424.01
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate imaging characteristics and artifacts of a nitinol stent with distal tantalum markers with computed tomography (CT) angiography and magnetic resonance (MR) angiography. MATERIALS AND METHODS: A vascular phantom was built to simulate in-stent restenosis. A nitinol stent with tantalum markers (Luminexx stent) was evaluated with CT angiography in different orientations relative to the z-axis and with MR angiography in different positions relative to both B0 and the readout gradient. Stenosis measurements were compared with conventional digital subtraction angiography for both modalities. In-stent signal intensity obtained with different flip angles was assessed in two nitinol stents with distal markers (Luminexx stent and SMART stent) and one without markers (Memotherm-FLEXX stent). RESULTS: Stenosis detection was not possible with CT angiography when the stent was perpendicular to the z-axis because of streak-like artifacts induced by tantalum markers. Stenosis evaluation with multiplanar reformation was accurate when the stent was in parallel and oblique orientations relative to the table axis. With MR angiography, metallic artifacts were mostly related to the stent orientation with B0, whereas orientation of the readout gradient had little influence. The mean error (overestimation) for stenosis measurements varied between 0.1% and 7.4% for CT imaging in parallel and oblique positions and 3.6% and 9.5% for MR imaging. Higher flip angles did not improve signal intensity inside the three stents tested. CONCLUSION: CT and MR angiography can be used for evaluating the patency of stents with distal markers that are parallel or oblique relative to the table axis (iliac, carotid, or femoral stents). MR angiography is preferred if the stent is perpendicular to the table axis (renal stent).
引用
收藏
页码:615 / 624
页数:10
相关论文
共 27 条
[1]   CT angiography: In vitro comparison of five reconstruction methods [J].
Addis, KA ;
Hopper, KD ;
Iyriboz, TA ;
Liu, Y ;
Wise, SW ;
Kasales, CJ ;
Blebea, JS ;
Mauger, DT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (05) :1171-1176
[2]   Improved lumen visualization in metallic vascular implants by reducing RF artifacts [J].
Bartels, LW ;
Bakker, CJG ;
Viergever, MA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :171-180
[3]   Gadolinium-enhanced 3D MR angiography of renal artery stenosis: A pilot comparison of maximum intensity projection, multiplanar reformatting, and 3D volume-rendering postprocessing algorithms [J].
Baskaran, V ;
Pereles, FS ;
Nemcek, AA ;
Carr, JC ;
Miller, FH ;
Ly, J ;
Krupinski, E ;
Finn, JP .
ACADEMIC RADIOLOGY, 2002, 9 (01) :50-59
[4]   Thin-section multidetector CT angiography of renal artery stents [J].
Behar, JV ;
Nelson, RC ;
Zidar, JP ;
DeLong, DM ;
Smith, TP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) :1155-1159
[5]   Artifact-free in-stent lumen visualization by standard magnetic resonance angiography using a new metallic magnetic resonance imaging stent [J].
Buecker, A ;
Spuentrup, E ;
Ruebben, A ;
Günther, RW .
CIRCULATION, 2002, 105 (15) :1772-1775
[6]   Transjugular intrahepatic portosystemic shunts: Assessment with helical CT angiography [J].
Chopra, S ;
Ghiatas, AA ;
Encarnacion, CE ;
Esola, CC ;
Chintapalli, KN ;
Palmaz, JC ;
Dodd, GD .
RADIOLOGY, 1997, 202 (01) :277-280
[7]  
CLOUTIER G, 2003, P SOC PHOTO-OPT INS, P707
[8]   METALLIC HIP IMPLANTS - CT WITH MULTIPLANAR RECONSTRUCTION [J].
FISHMAN, EK ;
MAGID, D ;
ROBERTSON, DD ;
BROOKER, AF ;
WEISS, P ;
SIEGELMAN, SS .
RADIOLOGY, 1986, 160 (03) :675-681
[9]   Plain and covered stent-grafts: In vitro evaluation of characteristics at three-dimensional MR angiography [J].
Hilfiker, PR ;
Quick, HH ;
Debatin, JF .
RADIOLOGY, 1999, 211 (03) :693-697
[10]  
Klemm T, 2000, J MAGN RESON IMAGING, V12, P606, DOI 10.1002/1522-2586(200010)12:4<606::AID-JMRI14>3.0.CO