Stability of Class II fixed functional appliance therapy-a systematic review and meta-analysis

被引:32
|
作者
Bock, Niko C. [1 ]
von Bremen, Julia [1 ]
Ruf, Sabine [1 ]
机构
[1] Univ Giessen, Dept Orthodont, Schlangenzahl 14, D-35392 Giessen, Germany
关键词
ADULT-CLASS-II; LONG-TERM-STABILITY; FACIAL PROFILE CHANGES; HERBST APPLIANCE; DIVISION-1; MALOCCLUSIONS; JASPER-JUMPER; FOLLOW-UP; DENTOSKELETAL CHANGES; OCCLUSAL CHANGES; POSITION CHANGES;
D O I
10.1093/ejo/cjv009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To systematically search for scientific evidence concerning the stability of treatment (Tx) results achieved by means of Class II fixed functional appliance therapy and to assess possible differences between appliances. An electronic search of databases and orthodontic journals was carried out (until December 2013), with supplemental hand searching. In addition to the names of all identified appliances, the term fixed functional was used in combination with each of the following search terms: long-term, post-Tx, relapse, retention, stability. To be included in the review, the articles had to contain clear data on: Class II Tx with a fixed functional appliance (> 5 patients), post-Tx period a parts per thousand yen 1 year, assessment of ANB angle, Wits appraisal, molar relationship, soft-tissue profile convexity excluding the nose, overjet and/or overbite. The literature search revealed 20 scientific investigations which corresponded to only two of the 76 identified appliances (Herbst and Twin Force Bite Corrector). As only one publication was found for the Twin Force Bite Corrector, a meta-analysis could only be performed for Herbst Tx. The data were extracted, pooled and weighted according to the number of patients in each study. The mean values for post-Tx relapse (percentages relative to the Tx changes) were: ANB angle 0.2 degrees (12.4 per cent), Wits appraisal 0.5mm (19.5 per cent), sagittal molar relationship 1.2mm/0.1 cusp widths (21.8 per cent /6.5 per cent); soft-tissue profile convexity excluding nose less than 0.1 degrees (1.0 per cent), overjet 1.8mm (26.2 per cent), overbite Class II:1 1.4mm (44.7 per cent), overbite Class II:2 1.0mm (22.2 per cent). The scientific evidence concerning the stability of Tx results is inexistent for most fixed functional appliances for Class II correction except for Herbst appliance Tx. Even if the evidence level of most included studies is rather low, good dentoskeletal stability without clinically relevant changes was found for most variables.
引用
收藏
页码:129 / 139
页数:11
相关论文
共 50 条
  • [1] Stability of Class II Fixed Functional Appliance Therapy - A Systematic Review and Meta-Analysis
    Bock, N. C.
    von Bremen, J.
    Ruf, S.
    INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2016, 48 (03): : 176 - 187
  • [2] Effects of skeletal anchorage on mandibular rotation with fixed functional appliance therapy in class II malocclusion patients-A systematic review and meta-analysis
    Muley, Aboli Jaydeep
    Chavan, Santosh Jetu
    Bhad, Wasundhara
    Shekokar, Shrutika S.
    Khade, Dipak M.
    APOS TRENDS IN ORTHODONTICS, 2023, 13 (03) : 176 - 183
  • [3] Effectiveness of Bionator functional orthodontic appliance in the treatment of Class II malocclusion in children: a systematic review and meta-analysis
    Li, Dongling
    Meng, Mingmei
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2025, 49 (02) : 38 - 50
  • [4] Mandibular propulsion appliance for adults with Class II malocclusion: a systematic review and meta-analysis
    Espinosa, Daybelis Gonzalez
    Santos, Milena
    dos Anjos Mendes, Sissy Maria
    Normando, David
    EUROPEAN JOURNAL OF ORTHODONTICS, 2020, 42 (02) : 163 - 173
  • [5] Treatment effects of fixed functional appliances in patients with Class II malocclusion: a systematic review and meta-analysis
    Zymperdikas, Vasileios F.
    Koretsi, Vasiliki
    Papageorgiou, Spyridon N.
    Papadopoulos, Moschos A.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2016, 38 (02) : 113 - 126
  • [6] Effects of fixed functional appliances with temporary anchorage devices on Class II malocclusion: A systematic review and meta-analysis
    Huang, Yanmei
    Sun, Wentian
    Xiong, Xin
    Zhang, Zihan
    Liu, Jin
    Wang, Jun
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2021, 10 (02) : 59 - 69
  • [7] Fixed Functional Appliance Therapy With and Without Skeletal Anchorage in Class II Malocclusion: A Systematic Review of Randomized Controlled Trials
    Rajamanickam, Preethi
    Sundari, K. K. Shantha
    JOURNAL OF ADVANCED ORAL RESEARCH, 2023, 14 (02) : 101 - 109
  • [8] Treatment effects of Carriere Motion Appliance on patients with class II malocclusion: A systematic review and meta-analysis
    Barakat, Daniah
    Bakdach, Wesam Mhd Mounir
    Youssef, Mohamed
    INTERNATIONAL ORTHODONTICS, 2021, 19 (03) : 353 - 364
  • [9] Effects of orthodontic treatment with activator appliance on patients with skeletal Class II malocclusion: a systematic review and meta-analysis
    Xie, Jiye
    Huang, Chunrong
    Yin, Kang
    Park, Juyoung
    Xu, Yanhua
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (12) : 12319 - 12334
  • [10] Metabolic adverse events associated with systemic corticosteroid therapy-a systematic review and meta-analysis
    Kulkarni, Spoorthy
    Durham, Hannah
    Glover, Luke
    Ather, Osaid
    Phillips, Veronica
    Nemes, Szilard
    Cousens, Leslie
    Blomgran, Parmis
    Ambery, Philip
    BMJ OPEN, 2022, 12 (12):