Assessment of atrial conduction time by tissue Doppler echocardiography and P-wave dispersion in patients with mitral annulus calcification

被引:23
作者
Pekdemir, Hasan [1 ,2 ]
Cansel, Mehmet [2 ]
Yagmur, Julide [2 ]
Acikgoz, Nusret [2 ]
Ermis, Necip [2 ]
Kurtoglu, Ertugrul [2 ]
Tasolar, Hakan [2 ]
Atas, Halil [2 ]
Ozdemir, Ramazan [2 ]
机构
[1] Inonu Univ, Tip Fak, Turgut Ozal Tip Merkezi Arastirma & Uygulama Hast, Kardiyoloji Anabilim Dalt, TR-44100 Malatya, Turkey
[2] Inonu Univ, Fac Med, Malatya, Turkey
关键词
Mitral annulus calcification; P-wave dispersion; Atrial electromechanical coupling; Tissue Doppler echocardiography; MATCHED CONTROL SUBJECTS; ANULAR CALCIUM; SHORT-TERM; FIBRILLATION; DURATION; HEMODIALYSIS; STENOSIS; ETIOLOGY; DEFECTS; VALVE;
D O I
10.1016/j.jelectrocard.2010.02.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to investigate atrial conduction time in patients with mitral annulus calcification (MAC) using P-wave dispersion (PWD) and electromechanical coupling measured with the surface electrocardiogram and the tissue Doppler echocardiography. Fifty-nine patients with MAC and 43 control subjects underwent resting the surface electrocardiogram and tissue Doppler echocardiography. The difference between the maximum (Pmax) and minimum P-wave durations was calculated and defined as PWD. Interatrial and intraatrial electromechanical delays were measured with tissue Doppler echocardiography. Both Pmax and PWD were higher in patients with MAC compared with controls (111.4 +/- 15.8 vs 97.3 +/- 18.8 milliseconds; P < .0001 and 46.4 +/- 14.6 vs 31.4 +/- 13.1 milliseconds; P < .0001, respectively). Both interatial and intraatrial conduction time were also delayed in patients with MAC compared with controls (29.8 +/- 13.3 vs 17.6 +/- 12.5 milliseconds; P < .0001; 9.4 +/- 5.1 vs 6.8 +/- 4.0 milliseconds; P < .008, respectively). Left atrial (LA) diameter was significantly higher in patients with MAC compared with controls (35.4 +/- 5.0 mm vs 32.3 +/- 4.2 mm; P < .001). The LA diameter correlated significantly with both interatrial conduction times and PWD (r = 0.56; P < .0001 and r = 0.47; P < .0001, respectively). There is a delay in both intraatrial and interatrial electromechanical coupling intervals in patients with MAC. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 28 条
  • [1] Mitral annulus calcification - a window to diffuse atherosclerosis of the vascular system
    Adler, Y
    Fink, N
    Spector, D
    Wiser, I
    Sagie, A
    [J]. ATHEROSCLEROSIS, 2001, 155 (01) : 1 - 8
  • [2] Association between mitral annular calcium and aortic atheroma as detected by transesophageal echocardiographic study
    Adler, Y
    Shohat-Zabarski, R
    Vaturi, M
    Shapira, Y
    Ehrlich, S
    Jortner, R
    Assali, A
    Zonshin, A
    Sagie, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (06) : 784 - 786
  • [3] CORRELATION OF ATRIAL-FIBRILLATION WITH PRESENCE OR ABSENCE OF MITRAL ANULAR CALCIUM IN 604 PERSONS OLDER THAN 60 YEARS
    ARONOW, WS
    SCHWARTZ, KS
    KOENIGSBERG, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (12) : 1213 - 1214
  • [4] P wave dispersion and short-term vs. late atrial fibrillation recurrences after cardioversion
    Boriani, G
    Diemberger, I
    Biffi, M
    Camanini, C
    Valzania, C
    Corazza, I
    Martignani, C
    Zannoli, R
    Branzi, A
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 101 (03) : 355 - 361
  • [5] Assessment of atrial electromechanical coupling and influential factors in nonrheumatic paroxysmal atrial fibrillation
    Cui, Qi-Qiong
    Zhang, Wei
    Wang, Hu
    Sun, Xin
    Wang, Rong
    Yang, Huan-Yi
    Meng, Xian-Qiang
    Zhang, Yun
    Wang, Hao
    [J]. CLINICAL CARDIOLOGY, 2008, 31 (02) : 74 - 78
  • [6] Comparison of different methods for manual P wave duration measurement in 12-lead electrocardiograms
    Dilaveris, P
    Batchvarov, V
    Gialafos, J
    Malik, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (10): : 1532 - 1538
  • [7] Simple electrocardiographic markers for the prediction of paroxysmal idiopathic atrial fibrillation
    Dilaveris, PE
    Gialafos, EJ
    Sideris, SK
    Theopistou, AM
    Andrikopoulos, GK
    Kyriakidis, M
    Gialafos, JE
    Toutouzas, PK
    [J]. AMERICAN HEART JOURNAL, 1998, 135 (05) : 733 - 738
  • [8] P-wave dispersion: A novel predictor of paroxysmal atrial fibrillation
    Dilaveris, PE
    Gialafos, JE
    [J]. ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2001, 6 (02) : 159 - 165
  • [9] A comparison of P-wave duration and dispersion in patients with short-term and long-term atrial fibrillation
    Dogan, A
    Acar, G
    Gedikli, O
    Ozaydin, M
    Nazli, C
    Altinbas, A
    Ergene, O
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2003, 36 (03) : 251 - 255
  • [10] CALCIFICATION OF THE MITRAL ANNULUS - ETIOLOGY, CLINICAL ASSOCIATIONS, COMPLICATIONS AND THERAPY
    FULKERSON, PK
    BEAVER, BM
    AUSEON, JC
    GRABER, HL
    [J]. AMERICAN JOURNAL OF MEDICINE, 1979, 66 (06) : 967 - 977