A three-stage experimental constructed wetland for treatment of domestic sewage: First 2 years of operation

被引:118
|
作者
Vymazal, Jan [1 ,2 ]
Kroepfelova, Lenka [1 ,2 ]
机构
[1] Czech Univ Life Sci Prague, Fac Environm Sci, Dept Landscape Ecol, Kostelec Cernymi Lesy 28163, Czech Republic
[2] OPS, ENKI, Trebon 37901, Czech Republic
关键词
Ammonia; Hybrid constructed wetland; Horizontal flow; Municipal sewage; Organics; Vertical flow; WASTE-WATER TREATMENT; VERTICAL-FLOW; PERFORMANCE; REMOVAL; DESIGN; NITROGEN; SYSTEM;
D O I
10.1016/j.ecoleng.2010.03.004
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
Hybrid constructed wetland systems have recently been used to treat wastewaters where high demand for removal of ammonia is required. However, these systems have not been used too often for small on-site treatment systems. This is because in many countries ammonia is not limited in the discharge from small systems. Hybrid systems have a great potential to reduce both ammonia and nitrate concentrations at the same time. In our study we employed a three-stage constructed wetland system consisting of saturated vertical-flow (VF) bed (2.5 m(2), planted with Phragmites australis), free-drained VF bed (1.5 m(2), planted with P. australis) and horizontal-flow (HF) bed (6 m(2), planted with Phalaris arundinacea) in series. All wetlands were originally filled with crushed rock (4-8 mm). However, nitrification was achieved only after the crushed rock was replaced with sand (0-4 mm) in the free-drain wetland. Also, original size of crushed rock proved to be too vulnerable to clogging and therefore, in the first wetlands the upper 40 cm was replaced by coarser fraction of crushed rock (16-32 mm) before the second year of operation started. The system was fed with mechanically pretreated municipal wastewater and the total daily flow was divided into two batches 12 h apart. The evaluation of the results from the period 2007 to 2008 indicated that such a system has a great potential for oxidation of ammonia and reduction of nitrate. The ammonia was substantially reduced in the free-drained VF bed and nitrate was effectively reduced in the final HF bed. The inflow mean NH4-N concentration of 29.9 mg/l was reduced to 6.5 mg/l with the average removal efficiency of 78.3%. At the same time the average nitrate-N concentration rose from 0.5 to only 2.7 mg/l at the outflow. Removal of BOD5 and COD amounted to 94.5% and 84.4%, respectively, with respective average outflow concentrations of 10 and 50 mg/l. Phosphorus was removed efficiently despite the fact that the system was not aimed at P removal and therefore no special media were used. Phosphorus removal amounted in 2008 to 65.4%, but the average outflow concentration of 1.8 mg/l is still high. The results of the present study indicate very efficient performance of the hybrid constructed wetlands, but optimal loading parameters still need to be adjusted. The capital cost of the experimental system is comparable to the conventional on-site treatment plant but the operations and maintenance costs are about one third of the conventional plant. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:90 / 98
页数:9
相关论文
共 38 条
  • [1] Three-stage hybrid constructed wetland system for wastewater treatment and reuse in warm climate regions
    Avila, Cristina
    Garfi, Marianna
    Garcia, Joan
    ECOLOGICAL ENGINEERING, 2013, 61 : 43 - 49
  • [2] Performance of a pilot-scale, three-stage constructed wetland system for domestic wastewater treatment
    Tuncsiper, Bilal
    Ayaz, Selma
    Akca, Luetfi
    Gunes, Kemal
    ENVIRONMENTAL TECHNOLOGY, 2009, 30 (11) : 1187 - 1194
  • [3] AN EXPERIMENTAL THREE-STAGE HYBRID CONSTRUCTED WETLAND SYSTEM FOR REMOVAL OF ORGANICS AND NUTRIENTS FROM DOMESTIC WASTEWATER
    Tuncsiper, Bilal
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2009, 8 (01): : 59 - 65
  • [4] Effect of first-stage aeration on treatment of domestic sewage in different hybrid constructed wetlands
    Yan, Fei-Long
    Wang, Yi
    Wang, Wen-Huai
    Zhang, Heng
    Zheng, Yu-Cong
    Kou, Xiao-Mei
    Wu, Shi-Zhang
    Shao, Tian
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (32) : 43402 - 43416
  • [5] Efficiency of constructed wetland systems cultivated with black oats treatment of domestic sewage
    Eustaquio Junior, Valdeir
    De Matos, Antonio Teixeira
    Vieira Lo Monaco, Paola Alfonsa
    De Campos, Lidiane Carvalho
    Borges, Alisson Carraro
    ACTA SCIENTIARUM-TECHNOLOGY, 2012, 34 (04) : 391 - 398
  • [6] Influence of hydraulic loading rate, simulated storm events and seasonality on the treatment performance of an experimental three-stage hybrid constructed wetland system
    Avila, Cristina
    Garcia, Joan
    Garfi, Marianna
    ECOLOGICAL ENGINEERING, 2016, 87 : 324 - 332
  • [7] A three-year study on the treatment of domestic-industrial mixed wastewater using a full-scale hybrid constructed wetland
    Dan, A.
    Deng, Yang-Yang
    Guo, Qin-Mei
    Jiang, Yu
    Chen, Chun-Xing
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (11) : 31256 - 31267
  • [8] Danish guidelines for small-scale constructed wetland systems for onsite treatment of domestic sewage
    Brix, H
    Arias, CA
    WATER SCIENCE AND TECHNOLOGY, 2005, 51 (09) : 1 - 9
  • [9] Constructed floating wetland for the treatment of domestic sewage: A real-scale study
    Benvenuti, Tatiane
    Hamerski, Fernando
    Giacobbo, Alexandre
    Bernardes, Andrea M.
    Zoppas-Ferreira, Jane
    Rodrigues, Marco As
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2018, 6 (05): : 5706 - 5711
  • [10] Treatment of Rural Domestic Sewage Anaerobic Filter Reactor Effluent by Constructed Wetland at Different Sewage Temperature
    Ladu, John Leju Celestino
    Lu, Xi-Wu
    Ping, Zhong-Zhao
    2015 INTERNATIONAL CONFERENCE ON ENVIRONMENT, MANUFACTURING INDUSTRY AND ECONOMIC DEVELOPMENT, (EMIED 2015), 2015, : 145 - 149