Determination of 241Am in sediments by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS)

被引:29
作者
Agarande, M [1 ]
Benzoubir, S [1 ]
Bouisset, P [1 ]
Calmet, D [1 ]
机构
[1] Inst Nucl Safety & Protect, Environm Radioact Measurement Lab, F-91400 Orsay, France
关键词
americium; sediments; ICP-MS;
D O I
10.1016/S0969-8043(01)00045-8
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Trace levels (pg kg(-1)) of Am-241 in sediments were determined by isotope dilution high resolution inductively coupled plasma mass spectrometry (1D HR ICP-MS) using a microconcentric nebulizer. Am-241 was isolated from major elements like Ca and Fe by different selective precipitations. In Further steps, Am was first separated from other transuranic elements and purified by anion exchange and extraction chromatography prior to the mass spectrometric measurements. The ID HR ICP-MS results are compared with isotope dilution alpha spectrometry. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 50 条
[31]   SELENIUM DETERMINATION IN PLASMA/SERUM BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP-MS): COMPARISON WITH GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY (GF-AAS) [J].
Janasik, Beata ;
Trzcinka-Ochocka, Malgorzata ;
Brodzka, Renata .
MEDYCYNA PRACY, 2011, 62 (05) :489-498
[32]   Quantification of trace elements in raw cow's milk by inductively coupled plasma mass spectrometry (ICP-MS) [J].
Ataro, A. ;
McCrindle, R. I. ;
Botha, B. M. ;
McCrindle, C. M. E. ;
Ndibewu, P. P. .
FOOD CHEMISTRY, 2008, 111 (01) :243-248
[33]   SURFACE WATER QUALITY ASSESSMENT USING ELECTROANALYTICAL METHODS AND INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP-MS) [J].
Bucurica, Ioan-Alin ;
Dulama, Ioana-Daniela ;
Radulescu, Cristiana ;
Banica, Andreea Laura .
ROMANIAN JOURNAL OF PHYSICS, 2022, 67 (3-4)
[34]   Method validation for a multi-element panel in serum by inductively coupled plasma mass spectrometry (ICP-MS) [J].
Johnson-Davis, Kamisha L. ;
Farnsworth, Candice ;
Law, Christian ;
Parker, Rebecca .
CLINICAL BIOCHEMISTRY, 2020, 82 :90-98
[35]   Analysis of minor and trace elements in milk and yogurts by inductively coupled plasma-mass spectrometry (ICP-MS) [J].
Khan, Naeem ;
Jeong, In Seon ;
Hwang, In Min ;
Kim, Jae Sung ;
Choi, Sung Hwa ;
Nho, Eun Yeong ;
Choi, Ji Yeon ;
Park, Kyung Su ;
Kim, Kyong Su .
FOOD CHEMISTRY, 2014, 147 :220-224
[36]   Optimization and Validation of an analytical methodology for the Determination of As, Cd, Pb and Hg in Blood Matrix by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) [J].
Vicentini Neto, Santos Alves ;
Gobbo dos Santos, Lisia Maria ;
Silva, Cristiane Barata ;
Fonseca, Mayssa Andrade ;
Magalhaes, Carolina Duque ;
Jacob, Silvana do Couto .
REVISTA VIRTUAL DE QUIMICA, 2022, :896-901
[37]   Intelligent Analysis of Samples by Semiquantitative Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) Technique: A Review [J].
Krzciuk, Karina .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2016, 46 (04) :284-290
[38]   ANALYSIS OF TOXIC ELEMENTS IN LEAVES AND FRUITS OF LOQUAT BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
Ali, Muhammad Moaaz ;
Rizwani, Hafiz Muhammad ;
Yousef, Ahmed Fathy ;
Zhi, Cao ;
Chen, Faxing .
ACTA SCIENTIARUM POLONORUM-HORTORUM CULTUS, 2021, 20 (05) :33-42
[39]   AEROSOL CHARACTERIZATION OF CONCENTRIC PNEUMATIC NEBULIZER USED IN INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
Kashani, A. ;
Mostaghimi, J. .
ATOMIZATION AND SPRAYS, 2010, 20 (05) :415-433
[40]   Minor and trace element analysis in breast milk using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) [J].
Yang, LC ;
Zhang, M ;
Lin, S ;
Chen, DY ;
Zheng, MH .
MICROCHIMICA ACTA, 2003, 142 (1-2) :85-88