Differentiation between benign and malignant ovarian masses using multiparametric MRI

被引:28
作者
Turkoglu, S. [1 ]
Kayan, M. [2 ]
机构
[1] Denizli State Hosp, Dept Radiol, TR-20010 Denizli, Turkey
[2] Suleyman Demirel Univ, Sch Med, Dept Radiol, TR-32260 Isparta, Turkey
关键词
Multiparametric magnetic resonance imaging; Apparent diffusion coefficient (ADC); Dynamic contrast enhancement (DCE) perfusion; Logistic models; Ovarian neoplasms; TUMORS; NEOPLASMS;
D O I
10.1016/j.diii.2020.01.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the capabilities of multiparametric MRI including dynamic contrast enhanced (DCE) perfusion and diffusion-weighted imaging (DWI) to discriminate between benign and malignant ovarian masses. Methods: A total of 43 women with a total of 43 ovarian masses were retrospectively included. They had a mean age of 51.26 +/- 18.05 (SD) years (range: 20-88 years). Twenty women had benign and 23 had malignant ovarian tumors. All women had multiparametric MRI examinations including DWI (b50-b800) and DCE perfusion imaging at 1-5 T. Results of DWI (apparent diffusion coefficient [ADC], b-800) and DCE imaging (volume transfer coefficient [Ktrans-] rate constant [K-ep], interstitial volume [V-e], initial area under the curve [iAUC]) were compared between benign and malignant ovarian masses. Results: Mean ADC was significantly lowed in malignant tumors (0.92 +/- 0.25 [SD] x 10(-3) mm(2)/s (range: 0.6-1.6 10(-3) mm(2)/s) than in benign tumors (1.37 +/- 0.69 [SD] 10(-3) mm(2)/s; range: 0.4-2.9 x 10(-3) mm(2)/s) (P=0.011). 8-800 was significantly greater in malignant tumors (80.61 +/- 24.73 [SD] s/mm(2); range: 24-110 s/mm(2)) than in benign ones (61.15 +/- 22.17 [SD] s/mm(2); range: 38-155 s/mm(2)) (P=0.010). ea"' was tower in benign tumors (0.13 +/- 0.06 [SD] min(-1); range: 0-0.2 min(-1)) than in malignant ones (0.25 +/- 0.16 [SD] min(-1); range: 0.1-0.8min(-1)) (P=0.002). K-ep was significantly greater in malignant tumors (0.55 +/- 0.19 [SD] min(-1); range: 0.1-1.9 min(-1)) than in benign ones (0.44 +/- 0.38 [SD] min(-1); range: 0.2-1.1 min(-1)) (P=0.003). iAUC was greater in malignant tumors (15.59 +/- 7.98 [SD] mM/min; range: 6.6-42.1 mM/min) than in benign ones (7.98 +/- 5.06 [SD] mM/min(-1); range: 0.2-17.7 nnM/min(-1)) (P=0.001). No differences in V-e were found between benign and malignant masses (P=0.084). The area under the ROC curve was significant for all parameters but Y e . Logistic regression analysis revealed 5.590 and 11.637 times higher malignancy risk for an ADC <= 0.93 x 10(-3) MM2/s and an iAUC >= 13.88 mM/min, respectively. Conclusion: Multiparametric MRI has high accuracy in discrimination between benign and malignant ovarian masses. Therefore, adding these methods to the more common MRI protocol can help select the best treatment option in women with ovarian mass. (C) 2020 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:147 / 155
页数:9
相关论文
共 25 条
[1]   Diagnosis of brain tumors using dynamic contrast-enhanced perfusion imaging with a short acquisition time [J].
Abe, Takashi ;
Mizobuchi, Yoshifumi ;
Nakajima, Kohei ;
Otomi, Yoichi ;
Irahara, Saho ;
Obama, Yuki ;
Majigsuren, Mungunkhuyag ;
Khashbat, Delgerdalai ;
Kageji, Teruyoshi ;
Nagahiro, Shinji ;
Harada, Masafumi .
SPRINGERPLUS, 2015, 4
[2]   Impact of Prognostic Factors on Survival Rates in Patients with Ovarian Carcinoma [J].
Arikan, Sevim Kalsen ;
Kasap, Burcu ;
Yetimalar, Hakan ;
Yildiz, Askin ;
Sakarya, Derya Kilic ;
Tatar, Sumeyra .
ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (15) :6087-6094
[3]   Diffusion-weighted imaging of solid or predominantly solid gynaecological adnexial masses: is it useful in the differential diagnosis? [J].
Bakir, B. ;
Bakan, S. ;
Tunaci, M. ;
Bakir, V. L. ;
Iyibozkurt, A. C. ;
Berkman, S. ;
Bengisu, E. ;
Salmaslioglu, A. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1003) :600-611
[4]   MUSCULOSKELETAL NEOPLASMS - STATIC AND DYNAMIC GD-DTPA ENHANCED MR IMAGING [J].
ERLEMANN, R ;
REISER, MF ;
PETERS, PE ;
VASALLO, P ;
NOMMENSEN, B ;
KUSNIERZGLAZ, CR ;
RITTER, J ;
ROESSNER, A .
RADIOLOGY, 1989, 171 (03) :767-773
[5]  
Fan XH, 2015, INT J CLIN EXP MED, V8, P19928
[6]  
Gity Masoumeh, 2019, Asian Pac J Cancer Prev, V20, P1073
[7]   Risk for Malignant and Borderline Ovarian Neoplasms Following Basic Preoperative Evaluation by Ultrasonography, Ca125 Level and Age [J].
Karadag, Burak ;
Kocak, M. ;
Kayikcioglu, F. ;
Ercan, F. ;
Dilbaz, B. ;
Kose, M. F. ;
Haberal, A. .
ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (19) :8489-8493
[8]   Diffusion-weighted echo planar imaging of ovarian tumors: Is it useful to measure apparent diffusion coefficients? [J].
Katayama, M ;
Masui, T ;
Kobayashi, S ;
Ito, T ;
Sakahara, H ;
Nozaki, A ;
Kabasawa, H .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (02) :250-256
[9]   Characterization of malignancy of adnexal lesions using ADC entropy: Comparison with mean ADC and qualitative DWI assessment [J].
Kierans, Andrea S. ;
Bennett, Genevieve L. ;
Mussi, Thais C. ;
Babb, James S. ;
Rusinek, Henry ;
Melamed, Jonathan ;
Rosenkrantz, Andrew B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (01) :164-171
[10]   Interest of Diffusion-Weighted Echo-Planar MR Imaging and Apparent Diffusion Coefficient Mapping in Gynecological Malignancies: A Review [J].
Levy, Antonin ;
Medjhoul, Aicha ;
Caramella, Caroline ;
Zareski, Elise ;
Berges, Oscar ;
Chargari, Cyrus ;
Boulet, Berenice ;
Bidault, Francois ;
Dromain, Clarisse ;
Balleyguier, Corinne .