Factors Affecting Wastewater Treatment and Power Generation of Constructed Wetland Microbial Fuel Cell Systems

被引:9
|
作者
Wan, Qiong [1 ]
Ren, Yingchun [1 ]
Wang, Cen [2 ]
Zhang, Xinyan [1 ]
Ju, Kai [1 ]
Li, Le [1 ]
Song, Haokun [1 ]
Wei, Dongyang [3 ]
机构
[1] Xian Univ Sci & Technol, Sch Architecture & Civil Engn, 58 Yanta Rd, Xian 710054, Peoples R China
[2] Wuhan Water Supply & Drainage Engn Design Inst Lt, Wuhan 430034, Hubei, Peoples R China
[3] Minist Ecol & Environm, Envirorunent Dev Ctr, Beijing 100029, Peoples R China
来源
POLISH JOURNAL OF ENVIRONMENTAL STUDIES | 2021年 / 30卷 / 06期
关键词
constructed wetland microbial fuel cell; electricity generation; HRT; COD; electrode spacing; HYDRAULIC RETENTION TIME; BIOELECTRICITY GENERATION; ELECTRICITY-GENERATION; TREATMENT EFFICIENCY; ELECTRON-TRANSFER; PERFORMANCE; MFC; ENERGY; REMOVAL; BACTERIAL;
D O I
10.15244/pjoes/135698
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Although there have been many studies on the process conditions of Constructed Wetlands (CW) and Microbial Fuel Cells (MFC), there are few studies on the Constructed Wetlands coupled with Microbial Fuel Cells. Currently, low power production is the main problem faced by Constructed Wetlands-Microbial Fuel Cell systems (CW-MFCs). This experiment intends to research the effects of HRT, influent COD and electrode spacing on wastewater treatment and power generation performance. In this experiment, CW-MFCs with two different electrode spacings (18 cm for reactor A and 28 cm for reactor B) were set up under continuous flow conditions. The effects of HRT, influent COD and eletrode spacing on wastewater treatment and power generation performance were explored using a single-factor controlled variable method. Experiment results showed that the extension of HRT was beneficial for contaminants removal and the power generation of the CW-MFCs, but the excessive extension was ineffective for the electricity output. The optimal HRT of the CW-MFCs was 24 h when influent COD was 500 mg.l(-1). Improving influent COD within the appropriate range (500 similar to 1000 mg.l(-1)) facilitated the power generation and contaminant removal performance of the CW-MFCs. The maximum output voltage and power density were obtained in reactor A when influent COD was 1000 mg.l(-1) and HRT was 24 h, which were 548 mV and 120 mW.m(-3), respectively. Compared with reactor B, reactor with smaller electrode spacing achieved better electricity generation and contaminant degradation under the optimal condition. Its average output voltage could be improved by 5.1 similar to 46.1% and the removal rates of COD and NH4+-N could also be improved by 0.2 similar to 4.9 % and -0.9 similar to 13.7 %, respectively. This phenomenon indicates that there was a significant positive correlation between the number of Gram-negative bacteria and the electricity production performance of the CW-MFCs, which was due to the difference in electron transfer efficiency. This study can provide operation parameters for the CW-MFCs process.
引用
收藏
页码:5285 / 5295
页数:11
相关论文
共 50 条
  • [21] Suitability of wetland microbial consortium for enhanced and sustained power generation from distillery effluent in microbial fuel cell
    Singh, Aradhana
    Kaushik, Anubha
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 4095 - 4111
  • [22] Performance evaluation of three constructed wetland-microbial fuel cell systems: wastewater treatment efficiency and electricity generation potential
    Hsu Htet Htet
    Rujira Dolphen
    Kamon Jirasereeamornkul
    Paitip Thiravetyan
    Environmental Science and Pollution Research, 2023, 30 : 96163 - 96180
  • [23] Phototrophic microbial fuel cells: a greener approach to sustainable power generation and wastewater treatment
    Sonawane, Jayesh M.
    Vijay, Ankisha
    Deng, Tianyang
    Ghosh, Prakash C.
    Greener, Jesse
    SUSTAINABLE ENERGY & FUELS, 2023, 7 (15) : 3482 - 3504
  • [24] Mechanism involved in the treatment of sulfamethoxazole in wastewater using a constructed wetland microbial fuel cell system
    Dai, Meixue
    Zhang, Yujia
    Wu, Yiming
    Sun, Ruipeng
    Zong, Wansong
    Kong, Qiang
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (05):
  • [25] Treatment of nitrogenous wastewater by a constructed wetland-coupled microbial fuel cell system: a review
    Yu, Xinxin
    Shi, Yucui
    You, Shaohong
    Tang, Gang
    WATER REUSE, 2024, 14 (02) : 208 - 225
  • [26] Performance optimization and microbial community evaluation for domestic wastewater treatment in a constructed wetland-microbial fuel cell
    Yang, Houyun
    Chen, Jian
    Yu, Li
    Li, Weihua
    Huang, Xianhuai
    Qin, Qian
    Zhu, Shuguang
    ENVIRONMENTAL RESEARCH, 2022, 212
  • [27] Integrated Constructed Wetland-Microbial Fuel Cell using Biochar as Wetland Matrix: Influence on Power Generation and Textile Wastewater Treatment
    Sonu, Kumar
    Sogani, Monika
    Syed, Zainab
    CHEMISTRYSELECT, 2021, 6 (32): : 8323 - 8328
  • [28] Enhanced denitrification and power generation of municipal wastewater treatment plants (WWTPs) effluents with biomass in microbial fuel cell coupled with constructed wetland
    Tao, Mengni
    Guan, Lin
    Jing, Zhaoqian
    Tao, Zhengkai
    Wang, Yue
    Luo, Hui
    Wang, Yin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 709
  • [29] Role of macrophyte species in constructed wetland-microbial fuel cell for simultaneous wastewater treatment and bioenergy generation
    Yang, Yan
    Zhao, Yaqian
    Tang, Cheng
    Xu, Lei
    Morgan, David
    Liu, Ranbin
    CHEMICAL ENGINEERING JOURNAL, 2020, 392
  • [30] The reaction of wastewater treatment and power generation of single chamber microbial fuel cell against substrate concentration and anode distributions
    Tan, Sing-Mei
    Ong, Soon-An
    Ho, Li-Ngee
    Wong, Yee-Shian
    Thung, Wei-Eng
    Teoh, Tean-Peng
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2020, 18 (02) : 793 - 807